Temperature -15° -22° CRefrigerant R290Static evaporators "evaporator grids".Manual defrost.2 grids can receive 1 PVC locker. Exterior manufactured in stainless steel 430, white interior in molded ABS (freezer: lacquered steel sheet).Door (reversible), with magnetic seal closure (by pressure), easy changing without tools, ergonomic handle.Key lock door, standardElectronic regulation, digital displayPolyurethane insulation (60 mm), without CFC'sCooling unit with climate category 4 (placed...
%
%
Cooling capacity 586 (W/f) for chamber volume 2,8 m³ / 2800 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 895 (W/f) for chamber volume 5,7 m³ / 5700 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 1058 (W/f) for chamber volume 7,6 m³ / 7600 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 1733 (W/f) for chamber volume 17,3 m³ / 17300 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 2463 (W/f) for chamber volume 30,5 m³ / 30500 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity rendered 1881 (W/f) for chamber volume 15,7 m³ / 15700 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation,...
%
Cooling capacity rendered 2961 (W/f) for chamber volume 28,2 m³ / 28200 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation,...
%
Cooling capacity rendered 1072 (W/f) for chamber volume 7,1 m³ / 7100 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation, as...
%
Cooling capacity rendered 1288 (W/f) for chamber volume 9,5 m³ / 9500 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation, as...
%
Wall-mounted version with raised rear edge.Predisposed for distance compressor unit (not included)Included: 1 grid GN1/1 (530x325mm), per door4 adjustable stainless steel feet.Can be installed on a base.Delivered without compressor unit, predisposed for remote unit placementInterior and exterior made of AISI 304 stainless steel (food grade), monocoque frameIndependent top (removable), in stainless steel (food grade) AISI 304Stainless steel racks and slides (antitilt), allowing the grids to be...
%