Frame in galvanized steel.Soundproof isolation.
%
Frame in galvanized steel.Soundproof isolation.
%
Frame in galvanized steel.Soundproof isolation.
%
Frame in galvanized steel.Soundproof isolation.
%
Frame in galvanized steel.Soundproof isolation.
%
Frame in galvanized steel.Soundproof isolation.
%
Frame in galvanized steel.Soundproof isolation.
%
Profile frame in aluminium.Panels with isolated double wall.Lateral inspection.Ventilator with direct suction.3 double filtering.
%
Profile frame in aluminium.Panels with isolated double wall.Lateral inspection.Ventilator with direct suction.3 double filtering.
%
Flow rate: 3000 m³/o. (Pressure drop 380 Pa). Centrifugal double-inlet ventilation units with built-in motor (operating temperature/resistance: -20° to 40°).Enclosed motor, IP54 protection rating.Galvanized steel casing with 5 mm internal sound insulation (polyurethane foam).Side inspection for after-sales service (S.A.V.).
%
Flow rate: 4500 m³/o. (Pressure drop 220 Pa). Centrifugal double-inlet ventilation units with built-in motor (operating temperature/resistance: -20° to 40°).Enclosed motor, IP54 protection rating.Galvanized steel casing with 5 mm internal sound insulation (polyurethane foam).Side inspection for after-sales service (S.A.V.).
%
Flow rate: 1300 m³/o. (Pressure drop 200 Pa). Centrifugal double-inlet ventilation units with built-in motor (operating temperature/resistance: -20° to 40°).Enclosed motor, IP54 protection rating.Galvanized steel casing with 5 mm internal sound insulation (polyurethane foam).Side inspection for after-sales service (S.A.V.).
%
Flow rate: 2500 m³/o. (Pressure drop 210 Pa). Centrifugal double-inlet ventilation units with built-in motor (operating temperature/resistance: -20° to 40°).Enclosed motor, IP54 protection rating.Galvanized steel casing with 5 mm internal sound insulation (polyurethane foam).Side inspection for after-sales service (S.A.V.).
%
Single-Phase Version.Pre-cut air inlet with a diameter of 250 mm.Airflow: 2200 m³/h (pressure drop: 200 Pa). Centrifugal single-inlet ventilation units with built-in motor (operating temperature/resistance: -20° +110°).Aluminum profiles and cladding panels made of galvanized "sandwich" type sheets with 20mm acoustic insulation (polyurethane foam).Panel with handle for easy access to the impeller for maintenance.Open motor access area for after-sales service inspection.Closed motor, IP54...
%
Single-Phase Version.Pre-cut air inlet with a diameter of 250 mm.Airflow: 3200 m³/h (pressure drop: 200 Pa). Centrifugal single-inlet ventilation units with built-in motor (operating temperature/resistance: -20° +110°).Aluminum profiles and cladding panels made of galvanized "sandwich" type sheets with 20mm acoustic insulation (polyurethane foam).Panel with handle for easy access to the impeller for maintenance.Open motor access area for after-sales service inspection.Closed motor, IP54...
%
Single-Phase Version.Pre-cut air inlet with a diameter of 315 mm.Airflow: 4200 m³/h (pressure drop: 200 Pa). Centrifugal single-inlet ventilation units with built-in motor (operating temperature/resistance: -20° +110°).Aluminum profiles and cladding panels made of galvanized "sandwich" type sheets with 20mm acoustic insulation (polyurethane foam).Panel with handle for easy access to the impeller for maintenance.Open motor access area for after-sales service inspection.Closed motor, IP54...
%
Single-Phase Version.Pre-cut air inlet with a diameter of 350 mm.Airflow: 5600 m³/h (pressure drop: 200 Pa). Centrifugal single-inlet ventilation units with built-in motor (operating temperature/resistance: -20° +110°).Aluminum profiles and cladding panels made of galvanized "sandwich" type sheets with 20mm acoustic insulation (polyurethane foam).Panel with handle for easy access to the impeller for maintenance.Open motor access area for after-sales service inspection.Closed motor, IP54...
%
%
2 Chambers: 1050x1050x150 mm (13,3 kW), 9 pizzas Ø 350 mm.2 ovens superposable (18+9 )Stainless steel front side, "decorative" removablehood, independent and "ergonomic" switch panel in painted steel.Bottom refractory stones chamber, high thickness fibreglass insulation.Adjustable steam exhauster, against shock built-in inner light, suitable for high temperatures 500°C.Door with spring system hinge, double thermal handle, large dimensions safety door glass, gasket in ceramic...
%
Capacity GN 2/1, 560x660xh310 mm.Oven enclosure and double-walled (deep-drawn) door made of stainless steel and provided with thermal insulation, lateral guides on 3 levels.Oven door on spring hinges, stainless steel handle.Stainless steel electric resistance heating, placed under the floor and in the oven vault, supplied with 1 rack.Thermostat control T°50°C to 290°C, with indicator light, grill with independent regulation, equipped with safety thermostat.Made of AISI 304 stainless...
%
Capacity GN 1/1, 560x370xh320 mm.Oven enclosure and double-walled (deep-drawn) door made of stainless steel with heat insulation, lateral guides on 3 levels.Oven door on spring hinges, stainless steel handle. Heating by 3 circular stainless steel heating elements coupled with a fan.Oven temperature regulation from 70°C to 270°C, by thermostat, supplied with 1 rack.Made of AISI 304 stainless steel.Adjustable stainless steel feet.
%
Capacity GN 2/1, 560x660xh310 mm.Oven enclosure and double-walled (deep-drawn) door made of stainless steel and provided with thermal insulation, lateral guides on 3 levels.Oven door on spring hinges, stainless steel handle.Gas heating by horizontal burners with stabilized flames, supplied with 1 grid.Regulation by thermostatic valve T°150°C to 290°C, pilot light ignition and safety system by thermocouple, piezoelectric device.Made of stainless steel AISI 304.Adjustable stainless steel feet.