Top 1.2 mm with rounding downwards 50 mm.Equipped fixed base shelf.Manufactured in stainless steel AISI 304.Standard delivered on adjustable feet in PVC (wheels in option).
%
Extern hoekelement van 45°.Realisatie in R.V.S.18/10 AISI 304, afwerking geborsteld korrel 220.Draagstruktuur in R.V.S.18/10 AISI 304.Montage op R.V.S. voeten in de hoogte rgelbaar.Bovenblad afgerond zijde klantBlad met neergeplooide rand van 70mm met dubbele omslag.Bovenblad verstevigd met geluidsdemper.Dikte bovenblad 15/10 mm.
%
Top 1,2mm with rounding downwards 50 mmEquipped fixed base shelfManufactured in stainless steel AISI 304 on adjustable feet in PVC.
%
Top 1.2 mm with rounding downwards 50 mmEquipped fixed base shelfManufactured in stainless steel AISI 304 on adjustable feet in PVC.
%
Superior top 1.5mm, rounded edges 70 mm.With a fix shelf base.Made in stainless steel with adjustable feet in stainless steel 150 mm.
%
Superior top 1.5mm, rounded edges 70 mm.With a fix shelf base.Made in stainless steel with adjustable feet in stainless steel 150 mm.
%
Superior top 1.5mm, rounded edges 70 mm.With a fix shelf base.Made in stainless steel with adjustable feet in stainless steel 150 mm.
%
Superior top 1.5mm, rounded edges 70 mm.With a fix shelf base.Made in stainless steel with adjustable feet in stainless steel 150 mm.
%
Version: with automatic oil filtering, automatic basket lifting and AUTO COOK.Made of AISI 304 stainless steel, deep-drawn "top" (20/10 mm) with overflow area, adjustable stainless steel feet (150/200mm), waterproof "IPX5".Tank dimensions 340x400xh575 mm.Quantity of oil in use, min. 21 lit. max. 23 lit.2 chrome steel baskets, dimensions 140x320xh150 mm.Y-shaped deep-drawn tank with rounded corners, equipped with a cold zone. Made of AISI 304 stainless steel. Drain tap (ball valve) and tank...
%
Cooling capacity rendered 633 (W/f) for chamber volume 3,0 m³ / 3000 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are...
%
Cooling capacity rendered 824 (W/f) for chamber volume 5,0 m³ / 5000 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are...
%
Cooling capacity rendered 1258 (W/f) for chamber volume 10,2 m³ / 10200 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity rendered 1509 (W/f) for chamber volume 13,2 m³ / 13200 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity rendered 2313 (W/f) for chamber volume 27,8 m³ /27800 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity 2139 (W/f) for room volume 18,1 m³ / 18100 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard...
%
Cooling capacity 3490 (W/f) for room volume 34,3 m³ / 34300 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by thermostatic valve.Also equipped with a high pressure switch (fixed calibration) (C-PMAX-R). Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a...
%
Cooling capacity 981 (W/f) for room volume 6,2 m³ / 6200 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard with a high...
%
Cooling capacity 1800 (W/f) for room volume 14,9 m³ / 14900 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard with a...
%
%