%
2 chambers 1080x720xh150 mm (7,9 kW)2x 6 pizzas of diam. 350 mm (or) 2x 2 pizzas of diam. 500 mm2 ovens superposable (12+6)Stainless steel chamber, bottom in refractory stone.Electric evacuation valve, for smokes - steams."Halogenous" lighting, built-in, "high T°".Offset door, "panoramic" porthole in safety glass.Heating by shielded electric elements in stainless steel, placed under the bottom and on the vault of the oven, stainless steel arch avoiding temperature drop while opening the...
%
%
Cooling capacity rendered 633 (W/f) for chamber volume 3,0 m³ / 3000 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are...
%
Cooling capacity rendered 824 (W/f) for chamber volume 5,0 m³ / 5000 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are...
%
Cooling capacity rendered 1258 (W/f) for chamber volume 10,2 m³ / 10200 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity rendered 1509 (W/f) for chamber volume 13,2 m³ / 13200 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity rendered 2313 (W/f) for chamber volume 27,8 m³ /27800 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity 2139 (W/f) for room volume 18,1 m³ / 18100 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard...
%
Cooling capacity 3490 (W/f) for room volume 34,3 m³ / 34300 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by thermostatic valve.Also equipped with a high pressure switch (fixed calibration) (C-PMAX-R). Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a...
%
Cooling capacity 981 (W/f) for room volume 6,2 m³ / 6200 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard with a high...
%
Cooling capacity 1800 (W/f) for room volume 14,9 m³ / 14900 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard with a...
%
3 drawers version max. load Height 320 mm.2 ventilated evaporator "treaty".6 adjustable stainless steel feet. Monocoque designInside and outside (top included) manufactured in stainless steel AISI 441 (also the back).Stamped interior bottom, rounded angles and corners (without roughness).Drawers with ergonomic handle, on telescopic slides, "snap-fit" closure by magnetic joint (easy replacement without tools), electrical resistance against the door, allowing the opening of the...
%
%
%
3 drawers version GN 1/1 (max. load Height 300 mm).2 ventilated evaporator "treaty".6 adjustable stainless steel feet. Monocoque design.Interior and exterior (including top) in AISI 304 stainless steel (food-grade) (rear also).Deep-drawn inner bottom and rounded corners and edges (no rough edges).Drawers with ergonomic handles, on telescopic slides, magnetic pressure seals (easy replacement, no tools required), electric resistance on counter-doors, allowing drawers to be opened.Class 5...