%
Realisation "double walled".Charging height glasses 300 mm. From 60-24 baskets/hour, cycle 60" - 120" - 150".Rotating wash and rinse arms (upper and below).Self cleaning sprinklers.Double wall door, "stamped", "removable" waterproof seal.Removable control panel.Automatic filling of the tank.Check valve.Hot water rinse (water consumption per cycle 2 liters), stainless steel boiler (2,6 Lit., 2,65 kW).Micro switch, when the door opens.Safety thermostat.Manufactured in stainless steel AISI...
%
Realisation "double walled".Version with incorporated water softener.Charging height glasses 300 mm. From 60-24 baskets/hour, cycle 60 - 120 - 150" .Rotating wash and rinse arms (upper and below).Self cleaning sprinklers.Double wall door, "stamped", "removable" waterproof seal.Removable control panel.Automatic filling of the tank.Check valve.Hot water rinse (water consumption per cycle 2 liters), stainless steel boiler (2,6 Lit., 2,65 kW).Micro switch, when the door opens.Safety...
%
Realisation "double walled".Version with incorporated discharge pump.Charging height glasses 300 mm. From 60-24 baskets/hour, cycle 60 - 120 - 150" .Rotating wash and rinse arms (upper and below).Self cleaning sprinklers.Double wall door, "stamped", "removable" waterproof seal.Removable control panel.Automatic filling of the tank.Check valve.Hot water rinse (water consumption per cycle 2 liters), stainless steel boiler (2,6 Lit., 2,65 kW).Micro switch, when the door opens.Safety...
%
Realisation "double walled".With anti-pollution device type AB (Break Tank), including the discharge pump (atmospheric boiler)Standard with disharge pump.Charging height glasses 300 mm. From 60-24 baskets/hour, cycle 60 - 120 - 150" .Rotating wash and rinse arms (upper and below).Self cleaning sprinklers.Double wall door, "stamped", "removable" waterproof seal.Removable control panel.Automatic filling of the tank.Check valve.Hot water rinse (water consumption per cycle 2 liters), stainless...
%
%
Charging height glasses 300 mm 30 baskets/hour,120-second cycle.Rotating wash and rinse arms (upper and lower).Self cleaning sprinklers.Tank, rounded edges (8 Lit., 0,6 kW).Stamped walls.Double walled door.Removable control panel.Automatic filling of the tank.Check valve.Hot water rinse (water consumption per cycle 2 liters), boiler (pressure) in stainless steel (2,6 Lit., 2,6 kW).Micro switch, when the door opens.Safety thermostat.Manufactured in stainless steel AISI 304.Standard: 2 baskets,...
%
Version with incorporated water softener.Charging height glasses 300 mm 30 baskets/hour,120-second cycle.Rotating wash and rinse arms (upper and lower).Self cleaning sprinklers.Tank, rounded edges (8 Lit., 0,6 kW).Stamped walls.Double walled door.Removable control panel.Automatic filling of the tank.Check valve.Hot water rinse (water consumption per cycle 2 liters), boiler (pressure) in stainless steel (2,6 Lit., 2,6 kW).Micro switch, when the door opens.Safety thermostat.Manufactured in...
%
Version with incorporated drain pumpCharging height glasses 300 mm 30 baskets/hour,120-second cycle.Rotating wash and rinse arms (upper and lower).Self cleaning sprinklers.Tank, rounded edges (8 Lit., 0,6 kW).Stamped walls.Double walled door.Removable control panel.Automatic filling of the tank.Check valve.Hot water rinse (water consumption per cycle 2 liters), boiler (pressure) in stainless steel (2,6 Lit., 2,6 kW).Micro switch, when the door opens.Safety thermostat.Manufactured in stainless...
%
Realisation in anodized aluminium.Cylinder diameter 130 mm.
%
Cooling capacity 586 (W/f) for chamber volume 2,8 m³ / 2800 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 895 (W/f) for chamber volume 5,7 m³ / 5700 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 1058 (W/f) for chamber volume 7,6 m³ / 7600 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 1733 (W/f) for chamber volume 17,3 m³ / 17300 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 2463 (W/f) for chamber volume 30,5 m³ / 30500 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity rendered 1881 (W/f) for chamber volume 15,7 m³ / 15700 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation,...
%
Cooling capacity rendered 2961 (W/f) for chamber volume 28,2 m³ / 28200 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation,...
%
Cooling capacity rendered 1072 (W/f) for chamber volume 7,1 m³ / 7100 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation, as...
%
Cooling capacity rendered 1288 (W/f) for chamber volume 9,5 m³ / 9500 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation, as...