%
Mechanical controls, mats manipulated by joystick.Table version (very compact), 4 adjustable cylinders.Manual controlsVariable speed (10 rpm to 60 rpm), with Inverter.Side tables 700x500 mm (foldable)Cylinder length 500 mmRoll opening 0 - 36 mm, rolling diameter 60 mmTravel speed 35 metres/minuteClosed overall dimensions 380x920xh850.Standard: 2 pastry rollers.Strips made with specific materials for food use.Precise regulation of the thickness of the dough sheet, constant production.Scrapers...
%
Mechanical controls, mats manipulated by joystick.Table version (very compact), 4 adjustable cylinders.Manual controls.1 speed.Side tables 700x500 mm (foldable).Cylinder length 500 mm.Roll opening from 0 - 36 mm, rolling diameter 60 mm.Travel speed 35 metres/minute.Closed overall dimensions 380x920xh850.Standard: 2 pastry rollers.Strips made with specific materials for food use.Precise regulation of the thickness of the dough sheet, constant production.Scrapers and supports made with specific...
%
Realisation in anodized aluminium.Cylinder diameter 130 mm.
%
Flow of 30 liters/hour.Tap with gooseneck to fill in the glasses, immediate pulling. Copper evaporator following the norms (avoiding any bacteriological development).Direct expansion system (French norms).Equipped with a triple action filter (sediment, limestone, chlorine).Thermic unit (ambient T° +32°C).Refrigerant gas R290 .CFC-free polyurethane insulationPredisposed for connection at the cold water system and a discharge.Realization in stainless steel .The equipment is manufactured...
%
Flow from 35 liters/hours.Water outlet controlled by a solenoid valve operated by a stainless steel pedal.Tap with gooseneck to fill in the glasses, immediate pulling.Lifting tray, removable bowl for better cleaning. Copper evaporator following the norms (avoiding any bacteriological development).Direct expansion system (French norms).Equipped with a triple action filter (sediment, limestone, chlorine).Thermic unit (ambient T° +32°C).Refrigerant gas R290 .CFC-free polyurethane...
%
Cooling capacity 586 (W/f) for chamber volume 2,8 m³ / 2800 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 895 (W/f) for chamber volume 5,7 m³ / 5700 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 1058 (W/f) for chamber volume 7,6 m³ / 7600 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 1733 (W/f) for chamber volume 17,3 m³ / 17300 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 2463 (W/f) for chamber volume 30,5 m³ / 30500 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity rendered 1881 (W/f) for chamber volume 15,7 m³ / 15700 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation,...
%
Cooling capacity rendered 2961 (W/f) for chamber volume 28,2 m³ / 28200 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation,...
%
Cooling capacity rendered 1072 (W/f) for chamber volume 7,1 m³ / 7100 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation, as...
%
Cooling capacity rendered 1288 (W/f) for chamber volume 9,5 m³ / 9500 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation, as...
%
Flow of 30 liters/hour.Tap with gooseneck to fill in the glasses, immediate pulling.Copper evaporator following the norms (avoiding any bacteriological development).Direct expansion system (French norms).Equipped with a triple action filter (sediment, limestone, chlorine).Thermic unit (ambient T° +32°C).Refrigerant gas R134a.CFC-free polyurethane insulationPredisposed for connection at the cold water system and a discharge.Realization in stainless steel .The equipment is manufactured...