Frame in galvanized steel.Soundproof isolation.
%
Frame in galvanized steel.Soundproof isolation.
%
Frame in galvanized steel.Soundproof isolation.
%
Frame in galvanized steel.Soundproof isolation.
%
Frame in galvanized steel.Soundproof isolation.
%
Frame in galvanized steel.Soundproof isolation.
%
Frame in galvanized steel.Soundproof isolation.
%
Profile frame in aluminium.Panels with isolated double wall.Lateral inspection.Ventilator with direct suction.3 double filtering.
%
Profile frame in aluminium.Panels with isolated double wall.Lateral inspection.Ventilator with direct suction.3 double filtering.
%
Flow rate: 3000 m³/o. (Pressure drop 380 Pa). Centrifugal double-inlet ventilation units with built-in motor (operating temperature/resistance: -20° to 40°).Enclosed motor, IP54 protection rating.Galvanized steel casing with 5 mm internal sound insulation (polyurethane foam).Side inspection for after-sales service (S.A.V.).
%
Flow rate: 4500 m³/o. (Pressure drop 220 Pa). Centrifugal double-inlet ventilation units with built-in motor (operating temperature/resistance: -20° to 40°).Enclosed motor, IP54 protection rating.Galvanized steel casing with 5 mm internal sound insulation (polyurethane foam).Side inspection for after-sales service (S.A.V.).
%
Flow rate: 1300 m³/o. (Pressure drop 200 Pa). Centrifugal double-inlet ventilation units with built-in motor (operating temperature/resistance: -20° to 40°).Enclosed motor, IP54 protection rating.Galvanized steel casing with 5 mm internal sound insulation (polyurethane foam).Side inspection for after-sales service (S.A.V.).
%
Flow rate: 2500 m³/o. (Pressure drop 210 Pa). Centrifugal double-inlet ventilation units with built-in motor (operating temperature/resistance: -20° to 40°).Enclosed motor, IP54 protection rating.Galvanized steel casing with 5 mm internal sound insulation (polyurethane foam).Side inspection for after-sales service (S.A.V.).
%
Single-Phase Version.Pre-cut air inlet with a diameter of 250 mm.Airflow: 2200 m³/h (pressure drop: 200 Pa). Centrifugal single-inlet ventilation units with built-in motor (operating temperature/resistance: -20° +110°).Aluminum profiles and cladding panels made of galvanized "sandwich" type sheets with 20mm acoustic insulation (polyurethane foam).Panel with handle for easy access to the impeller for maintenance.Open motor access area for after-sales service inspection.Closed motor, IP54...
%
Single-Phase Version.Pre-cut air inlet with a diameter of 250 mm.Airflow: 3200 m³/h (pressure drop: 200 Pa). Centrifugal single-inlet ventilation units with built-in motor (operating temperature/resistance: -20° +110°).Aluminum profiles and cladding panels made of galvanized "sandwich" type sheets with 20mm acoustic insulation (polyurethane foam).Panel with handle for easy access to the impeller for maintenance.Open motor access area for after-sales service inspection.Closed motor, IP54...
%
Single-Phase Version.Pre-cut air inlet with a diameter of 315 mm.Airflow: 4200 m³/h (pressure drop: 200 Pa). Centrifugal single-inlet ventilation units with built-in motor (operating temperature/resistance: -20° +110°).Aluminum profiles and cladding panels made of galvanized "sandwich" type sheets with 20mm acoustic insulation (polyurethane foam).Panel with handle for easy access to the impeller for maintenance.Open motor access area for after-sales service inspection.Closed motor, IP54...
%
Single-Phase Version.Pre-cut air inlet with a diameter of 350 mm.Airflow: 5600 m³/h (pressure drop: 200 Pa). Centrifugal single-inlet ventilation units with built-in motor (operating temperature/resistance: -20° +110°).Aluminum profiles and cladding panels made of galvanized "sandwich" type sheets with 20mm acoustic insulation (polyurethane foam).Panel with handle for easy access to the impeller for maintenance.Open motor access area for after-sales service inspection.Closed motor, IP54...
%
%
2 separate cooking zones Ø 230 mm (2x 3,5 kW). Made of AISI 304 stainless steel, deep-drawn "top" (15/10 mm), levelling cylinders, waterproof "IPX4".Ceramic glass induction hob (6 mm). Focus diameter 230 mm, energy regulator.Principle of INDUCTION: The heat is produced by a magnetic field directly inside the container, this field is created electronically, there is no heating element, which gives it great security. Cooking is done almost without any heat loss; it is the most economical...
%
2 separate cooking zones Ø 230 mm (2x 3,5 kW).Made of AISI 304 stainless steel, deep-drawn "top" (15/10 mm), levelling cylinders, waterproof "IPX4".Ceramic glass induction hob (6 mm). Focus diameter 230 mm, energy regulator.Principle of INDUCTION:The heat is produced by a magnetic field directly inside the container, this field is created electronically, there is no heating element, which gives it great security. Cooking is done almost without any heat loss; it is the most economical...
%
2 plates Ø 230 mm, independent (2x 2.6 kW). Made of AISI 304 stainless steel, deep-drawn "top" (15/10 mm), adjustable cylinders, waterproof "IPX4".Cast iron plates, with a stainless steel sealing edge. Regulation by 7-position switch.Appliances built in compliance with current standards (CE)
%
2 plates Ø 230 mm, independent (2x 2.6 kW). Made of AISI 304 stainless steel, deep-drawn "top" (15/10 mm), adjustable cylinders, waterproof "IPX4".Cast iron plates, with a stainless steel sealing edge. Regulation by 7-position switch.Appliances built in compliance with current standards (CE)
%
2 separate cooking fields Ø 230 mm (2x 2.2 kW). Made of AISI 304 stainless steel, deep-drawn "top" (15/10 mm), adjustable cylinders.Ceramic glass (6 mm), with radiant fireplaces diameter 300 mm. Glass ceramic plates are characterized by a fast temperature setting. Graduated energy regulator for each fireplace.Appliances built in compliance with current standards (CE)
%
2 separate cooking fields Ø 230 mm (2x 2.2 kW). Made of AISI 304 stainless steel, deep-drawn "top" (15/10 mm), adjustable cylinders.Ceramic glass (6 mm), with radiant fireplaces diameter 300 mm. Glass ceramic plates are characterized by a fast temperature setting. Graduated energy regulator for each fireplace.Appliances built in compliance with current standards (CE)