Frame in galvanized steel.Soundproof isolation.
%
Frame in galvanized steel.Soundproof isolation.
%
Frame in galvanized steel.Soundproof isolation.
%
Frame in galvanized steel.Soundproof isolation.
%
Frame in galvanized steel.Soundproof isolation.
%
Frame in galvanized steel.Soundproof isolation.
%
Frame in galvanized steel.Soundproof isolation.
%
Profile frame in aluminium.Panels with isolated double wall.Lateral inspection.Ventilator with direct suction.3 double filtering.
%
Profile frame in aluminium.Panels with isolated double wall.Lateral inspection.Ventilator with direct suction.3 double filtering.
%
Flow rate: 3000 m³/o. (Pressure drop 380 Pa). Centrifugal double-inlet ventilation units with built-in motor (operating temperature/resistance: -20° to 40°).Enclosed motor, IP54 protection rating.Galvanized steel casing with 5 mm internal sound insulation (polyurethane foam).Side inspection for after-sales service (S.A.V.).
%
Flow rate: 4500 m³/o. (Pressure drop 220 Pa). Centrifugal double-inlet ventilation units with built-in motor (operating temperature/resistance: -20° to 40°).Enclosed motor, IP54 protection rating.Galvanized steel casing with 5 mm internal sound insulation (polyurethane foam).Side inspection for after-sales service (S.A.V.).
%
Flow rate: 1300 m³/o. (Pressure drop 200 Pa). Centrifugal double-inlet ventilation units with built-in motor (operating temperature/resistance: -20° to 40°).Enclosed motor, IP54 protection rating.Galvanized steel casing with 5 mm internal sound insulation (polyurethane foam).Side inspection for after-sales service (S.A.V.).
%
Flow rate: 2500 m³/o. (Pressure drop 210 Pa). Centrifugal double-inlet ventilation units with built-in motor (operating temperature/resistance: -20° to 40°).Enclosed motor, IP54 protection rating.Galvanized steel casing with 5 mm internal sound insulation (polyurethane foam).Side inspection for after-sales service (S.A.V.).
%
Single-Phase Version.Pre-cut air inlet with a diameter of 250 mm.Airflow: 2200 m³/h (pressure drop: 200 Pa). Centrifugal single-inlet ventilation units with built-in motor (operating temperature/resistance: -20° +110°).Aluminum profiles and cladding panels made of galvanized "sandwich" type sheets with 20mm acoustic insulation (polyurethane foam).Panel with handle for easy access to the impeller for maintenance.Open motor access area for after-sales service inspection.Closed motor, IP54...
%
Single-Phase Version.Pre-cut air inlet with a diameter of 250 mm.Airflow: 3200 m³/h (pressure drop: 200 Pa). Centrifugal single-inlet ventilation units with built-in motor (operating temperature/resistance: -20° +110°).Aluminum profiles and cladding panels made of galvanized "sandwich" type sheets with 20mm acoustic insulation (polyurethane foam).Panel with handle for easy access to the impeller for maintenance.Open motor access area for after-sales service inspection.Closed motor, IP54...
%
Single-Phase Version.Pre-cut air inlet with a diameter of 315 mm.Airflow: 4200 m³/h (pressure drop: 200 Pa). Centrifugal single-inlet ventilation units with built-in motor (operating temperature/resistance: -20° +110°).Aluminum profiles and cladding panels made of galvanized "sandwich" type sheets with 20mm acoustic insulation (polyurethane foam).Panel with handle for easy access to the impeller for maintenance.Open motor access area for after-sales service inspection.Closed motor, IP54...
%
Single-Phase Version.Pre-cut air inlet with a diameter of 350 mm.Airflow: 5600 m³/h (pressure drop: 200 Pa). Centrifugal single-inlet ventilation units with built-in motor (operating temperature/resistance: -20° +110°).Aluminum profiles and cladding panels made of galvanized "sandwich" type sheets with 20mm acoustic insulation (polyurethane foam).Panel with handle for easy access to the impeller for maintenance.Open motor access area for after-sales service inspection.Closed motor, IP54...
%
%
Refrigerant expansion R290.Internal dimensions: 890x510xh665 mm.Temperature: -15° -25°.Supplied as standard with 1 basket. External construction in white lacquered sheet steel.Sliding covers, natural aluminium frame, Thermopane® windows.Key lock (standard).Mechanical thermostat, T° -15° -25°. Analog thermometer, for displaying the internal temperature.On/Off switch.Hermetic unit for ambient temperature +32°C, ventilated condenser.Static evaporator, placed in the "coil" walls.Manual...
%
Refrigerant expansion R290.Internal dimensions: 1180x510xh665 mm.Temperature: -15° -25°.Supplied as standard with 1 basket.External construction in white lacquered sheet steel.Sliding covers, natural aluminium frame, Thermopane® windows.Key lock (standard).Mechanical thermostat, T° -15° -25°.Analog thermometer, for displaying the internal temperature.On/Off switch.Hermetic unit for ambient temperature +32°C, ventilated condenser.Static evaporator, placed in the "coil" walls.Manual defrosting,...
%
8 spits (till 900mm) standard accessories, each for 6 chickens (1,25kg)Version on wheels (Diam. 100 mm)Manufactured in stainless steel AISI 304.Capacity 6 chickens per spit, all the spits are delivered with 2 final and 4 intermediate picks, with athermal handle.Electric heating : by "vitroceramic" heaters, source of uniform heat.Independent regulation of each spit.All our models are equipped with frontal "safety" windows, with magnetic closure, athermal handles.Lighting, by halogen...
%
8 spits (till 900mm) standard accessories, each for 6 chickens (1,25kg)Version with wheels (Diam. 100 mm)Manufactured in stainless steel AISI 304.Capacity 6 chickens per spit, all the spits are delivered with 2 final and 4 intermediate picks, with athermal handle.Gas heating: by ceramic radiants, fit with safety thermocouple, removable heat deflectors.Independent regulation of each spit.All our models are equipped with frontal "safety" windows, with magnetic closure, athermal...
%
Energy class: D.Refrigerant expansion R290.Internal dimensions: 890x510xh665 mm.Temperature: -15° -25°.Supplied as standard with 1 basket. External construction in white lacquered sheet steel.Sliding covers, natural aluminium frame, Thermopane® windows.Key lock (standard).Mechanical thermostat, T° -15° -25°.Digital thermometer for displaying internal temperature.On/Off switch.Hermetic unit for ambient temperature +32°C, ventilated condenser.Static evaporator, placed in the "coil" walls.Manual...
%
Energy class: D.Refrigerant expansion R290.Internal dimensions: 1180x510xh665 mm.Temperature: -15° -25°.Supplied as standard with 1 basket. External construction in white lacquered sheet steel.Sliding covers, natural aluminium frame, Thermopane® windows.Key lock (standard).Mechanical thermostat, T° -15° -25°.Digital thermometer, for displaying the internal temperature.On/Off switch.Hermetic unit for ambient temperature +32°C, ventilated condenser.Static evaporator, placed in the "coil"...