High version, easier loading / unloading of baskets,..."Double-walled" Standard version Load height 405 mmplate height 380 mm From 60 till 24 baskets/hour, cycles 60'' - 120'' - 150" or continuousRotating wash and rinse arms (upper and lower), lower in stainless steelSelf-cleaning jetsTank (23 Lt., 2,1 kW) with rounded edges, "stamped" bottom"Stamped" double walled door, "removable" gasketRemovable control panelAutomatic filling of the tankCheck valveHot water rinse (2,5 Lt. water consumption...
%
Low version, installation option under sinks and cupboards etc...."Double-walled" VersionLoad height 405 mmPlate height 380 mm From 60 till 24 baskets/hour, cycles 60'' - 120'' - 150" or continuousRotating wash and rinse arms (upper and lower), lower in stainless steelSelf-cleaning jetsTank (23 Lt., 2,1 kW) with rounded edges, "stamped" bottom"Stamped" double walled door, "removable" gasketRemovable control panelAutomatic filling of the tankCheck valveHot water rinse (2,5 Lt. water...
%
Realisation "double walled". with thermic insulation.Watersoftener continuously, incorporated (WARNING: connection to cold water).Charging height diam. 465 mm.Standard rinsing pump (atmospheric boiler). Control panel at the top of the hood, digital display.Basket 600x500 mm, capacity 22 plates, dishes 600x400 (see accessories), beer baskets 600x400 to 135 Lt, always the possibility of using 500x500 mm baskets. 3 cycles: 60 '- 110' - 150 '' or continuous.Device opening and closing cover on...
%
Realization in "double walls" with thermal insulationIntegration of the "Green System H.R.S. Condenser-recovery of vapors, great energy saving (ATTENTION: connection to cold water)Continuous water softener, incorporated (ATTENTION: connection to cold water)Loading height 465 mmStandard flush pump (atmospheric boiler). Control panel on top of the cover, digital displayBasket 600x500 mm, capacity 22 plates, plates 600x400 (see accessory), beer baskets 600x400 up to 135 Lt, still possible to use...
%
%
%
%
%
%
Energy class: C.Coolant expansion R600a via capillary tube.Internal dimensions: 860x480xh725 mm.Temperature: -14° -24°Supplied with 1 basket. Solid hinged lid with key lock.65 mm CFC-free polyurethane insulation.Mechanical thermostat.Thermometer for internal temperature display.On/off switch.Hermetic unit for ambient temperature up to +32°C, static condenser.Static evaporator located in coil within walls.Manual defrost with front drainage for condensed water.Internal finish in "WAFFLE"...
%
Energy class: D.Coolant expansion R600a via capillary tube.Internal dimensions: 1380x480xh725 mm.Temperature: -14° -24°Supplied with 1 basket. Solid hinged lid with key lock.65 mm CFC-free polyurethane insulation.Mechanical thermostat.Thermometer for internal temperature display.On/off switch.Hermetic unit for ambient temperature up to +32°C, static condenser.Static evaporator located in coil within walls.Manual defrost with front drainage for condensed water.Internal finish in "WAFFLE"...
%
Cooling capacity 586 (W/f) for chamber volume 2,8 m³ / 2800 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 895 (W/f) for chamber volume 5,7 m³ / 5700 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 1058 (W/f) for chamber volume 7,6 m³ / 7600 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 1733 (W/f) for chamber volume 17,3 m³ / 17300 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 2463 (W/f) for chamber volume 30,5 m³ / 30500 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity rendered 1881 (W/f) for chamber volume 15,7 m³ / 15700 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation,...
%
Cooling capacity rendered 2961 (W/f) for chamber volume 28,2 m³ / 28200 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation,...
%
Cooling capacity rendered 1072 (W/f) for chamber volume 7,1 m³ / 7100 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation, as...
%
Cooling capacity rendered 1288 (W/f) for chamber volume 9,5 m³ / 9500 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation, as...