High version, easier loading / unloading of baskets,..."Double-walled" Standard versionWith anti-pollution device, AB type (Break Tank), including rinse pump (atmospheric boiler)Load height 405 mmPlate height 380 mm3 stages: washing, discharge, rinseDrain pump, standardRinse pump, standard (atmospheric boiler) Double-walled version completely in stainless steel AISI 304. - From 60 till 24 baskets/hour, cycles 60'' - 120'' - 150" or continuous - Rotating wash and rinse arms (upper and lower),...
%
Low version, installation option under sinks and cupboards etc...."Double-walled" VersionWith anti-pollution device, AB type (Break Tank), including rinse pump (atmospheric boiler)Load height 405 mmPlate height 380 mm3 stages: washing, discharge, rinseDrain pump, standardRinse pump, standard (atmospheric boiler) Double-walled version completely in stainless steel AISI 304. - From 60 till 24 baskets/hour, cycles 60'' - 120'' - 150" or continuous - Rotating wash and rinse arms (upper and...
%
Water softener continuously, incorporated (ATTENTION: cold water connection) Height of load Ø 465 mm.Realisation "double walled". with thermic insulation.From 60 to 24 baskets/hour, PLD cycles 60", 120", 150" or continuous.3 phases: wash, unload, rinse.Water consumption per cycle 3 liters.Vertical wash pump (double flux), auto-drain and auto-wash (1,5 Kw).Standard discharge pump.Standard rinse pump (atmospheric boiler) Control panel at the top of the hood, digital display.Basket 600x500 mm,...
%
Integration of the "Green System H.R.S." Condenser vapor-recovery unit, big energy savings (ATTENTION: connection to cold water)Watersofterner continuously, incorporated. (ATTENTION: connection to cold water)Height of load Ø 465 mmRealisation "double walled". with thermic insulation.From 60 to 24 baskets/hour, PLD cycles 60", 120", 150" or continuous.3 phases: wash, unload, rinse.Water consumption per cycle 3 liters.Standard discharge pump.Standard rinse pump (atmospheric boiler) Control...
%
Cooling capacity rendered 633 (W/f) for chamber volume 3,0 m³ / 3000 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are...
%
Cooling capacity rendered 824 (W/f) for chamber volume 5,0 m³ / 5000 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are...
%
Cooling capacity rendered 1258 (W/f) for chamber volume 10,2 m³ / 10200 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity rendered 1509 (W/f) for chamber volume 13,2 m³ / 13200 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity rendered 2313 (W/f) for chamber volume 27,8 m³ /27800 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity 2139 (W/f) for room volume 18,1 m³ / 18100 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard...
%
Cooling capacity 3490 (W/f) for room volume 34,3 m³ / 34300 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by thermostatic valve.Also equipped with a high pressure switch (fixed calibration) (C-PMAX-R). Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a...
%
Cooling capacity 981 (W/f) for room volume 6,2 m³ / 6200 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard with a high...
%
Cooling capacity 1800 (W/f) for room volume 14,9 m³ / 14900 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard with a...
%
2 drawers version GN 1/1max. load Height 320 mm1 ventilated evaporator "treaty".4 adjustable stainless steel feet.Monocoque designInside and outside (top included) manufactured in stainless steel AISI 441 (also the back).Stamped interior bottom, rounded angles and corners (without roughness).Drawers with ergonomic handle, on telescopic slides, "snap-fit" closure by magnetic joint (easy replacement without tools), electrical resistance against the door, allowing the opening of the...