Unit width 400 mm, small footprint.Cooling capacity 671 (W/f) for chamber volume 3,6 m³ / 3600 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Unit width 400 mm, small footprint.Cooling capacity 817 (W/f) for chamber volume 4,8 m³ / 4800 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Unit width 400 mm, small footprint.Cooling capacity 953 (W/f) for chamber volume 6,1 m³ / 6100 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Cooling capacity 1577 (W/f) for chamber volume 16,3 m³ / 16300 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 1914 (W/f) for chamber volume 19,4 m³ / 19400 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 2343 (W/f) for chamber volume 29,2 m³ / 29200 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 2547 (W/f) for chamber volume 34,2 m³ / 34200 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity rendered 1960 (W/f) for chamber volume 16,4 m³ / 16400 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice formation. Refrigerant gas...
%
Cooling capacity rendered 3389 (W/f) for chamber volume 37,6 m³ / 37600 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice formation. Refrigerant gas...
%
Unit width 400 mm, small footprint.Cooling capacity rendered 975 (W/f) for chamber volume 6 m³ / 6000 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice...
%
Unit width 400 mm, small footprint.Cooling capacity rendered 1302 (W/f) for chamber volume 10,6 m³ / 10600 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent...
%
Capacity: 10x GN 1/1 (or) 10x EN 600x400 mm (supplied: 1x GN 1/1 grid)Production per cycle: 36 Kg (+70°C +3°C) or 25 Kg (+70°C -18°C)Core probe as standard"Anti-tilt" structure in stainless steel wire (removable), spacing for 67 mm platesReversible door (on request: Kit left hinges) with integrated handle (not protruding)Hinges (right) with automatic return (90° locking).Insulation 60 mm thick.4 adjustable stainless steel feet.TOUCH SCREEN" controls 5" screen, high definition color touch...
%
Capacity: 15x GN 1/1 (or) 15x EN 600x400 mm (supplied: 1x GN 1/1 grid)Production per cycle: 48 Kg (+70°C +3°C) or 32 Kg (+70°C -18°C)Core probe as standard"Anti-tilt" structure in stainless steel wire (removable), spacing for 67 mm platesReversible door (on request: Kit left hinges) with integrated handle (not protruding)Hinges (right) with automatic return (90° locking).Insulation 60 mm thick.4 adjustable stainless steel feet.TOUCH SCREEN" controls 5" screen, high definition color touch...
%
Capacity: 15x GN 1/1 (or) 15x EN 600x400 mm (supplied: 1x GN 1/1 grid)Production per cycle: 48 Kg (+70°C +3°C) or 32 Kg (+70°C -18°C)Core probe as standard"Anti-tilt" structure in stainless steel wire (removable), spacing for 67 mm platesReversible door (on request: Kit left hinges) with integrated handle (not protruding)Hinges (right) with automatic return (90° locking).Insulation 60 mm thick.4 adjustable stainless steel feet.TOUCH SCREEN" controls 5" screen, high definition color touch...
%
Capacity: 3 GN 1/1 (supplied: 1x GN 1/1 grid)Production per cycle: 12 Kg ( +70° C +3° C) or 8 Kg ( +70° C -18° C)Core probe as standardAnti-tilt" structure in stainless steel wire (removable), spacing for 67 mm platesDoor (non-reversible) with integrated handle (not projecting)Hinges (left) with automatic return (90° locking).Insulation 50 mm thick4 adjustable cylinders.TOUCH SCREEN" controls 5" screen, high definition color touch screen, allowing the user to customize all major functions.4...
%
Capacity: 5x GN 1/1 (supplied: 1x GN 1/1 grid)Production per cycle: 18 Kg ( +70°C +3°C) or 12 Kg ( +70°C -18°C)Core probe as standard"Anti-tilt" structure in stainless steel wire (removable), spacing for 67 mm platesReversible door (See PK-CIG Kit) with integrated handle (not protruding)Hinges (right) with automatic return (90° locking).Insulation 60 mm thick.4 adjustable stainless steel feet.TOUCH SCREEN" controls 5" screen, high definition color touch screen, allowing the user to customize...
%
Capacity: 5x GN 1/1 (or) 5x EN 600x400 mm (supplied: 1x GN 1/1 grid)Production per cycle: 18 Kg ( +70°C +3°C) or 12 Kg ( +70°C -18°C)Core probe as standard"Anti-tilt" structure in stainless steel wire (removable), spacing for 67 mm platesReversible door (see PK-CIG kit) with integrated handle (not protruding)Hinges (right) with automatic return (90° locking).Insulation 60 mm thick.4 adjustable stainless steel feet.TOUCH SCREEN" controls 5" screen, high definition color touch screen, allowing...
%
%
Capacity: 10x GN 1/1 (or) 10x EN 600x400 mm (optional grids and plates).Production per cycle: 40 Kg (+70° C +3° C) or 25 Kg (+70° C -18° C).Core probe as standard.Anti-tilting" structure in stainless steel wire (removable), spacing for GN 1/1 (75 mm) & EN 600x400 (44 mm) plates.Door with integrated "non protruding" handle (On order reversible)Upper panel for accessibility to the compressor unit, hinged, easy inspection.Hinges with automatic return (90° locking).Insulation 70 mm...
%
%
%
Capacity: 10x GN 1/1 (or) 10x EN 600x400 mm (optional grills and plates).Prodution per cycle : 40 Kg (+70° C +3° C) or 25 Kg (+70° C -18° C).Core probe, serial."Anti tilt" Structure made of stainless steel wire (removable), space for trays GN 1/1 (75 mm) & EN 600x400 (44 mm).Door with integrated "non-projecting" handle (reversible on order).Top panel for access to the compressor unit, on hinges, easy inspection. - Hinges with automatic return (blocking at 90 °).Insulation 70 mm...
%
Capacity: 10x GN 2/1 (or) 10 x EN 600X800 - 20 x 600X400 mm (grids and plates optional).Production per cycle: 75 Kg (+70° C +3° C) or 50Kg (+70° C -18° C).Core probe as standard.Anti-tilting" structure in stainless steel wire (removable), spacing for 50 & 75 mm plates.Door (non-reversible) with integrated handle (not salient).Hinges with automatic return (90° locking).Insulation 70 mm thickness.Refrigerant expansion R404A by thermostatic expansion valve.4 adjustable stainless steel...
%
Predisposed for remote compressor unit (not included).Electrical panel placed above the cell (supplied as standard)Door (non-reversible) with handle.Maximum" dimensions of the trolley: 720x900xh1880Insulation 80 mm thickness.TOUCH SCREEN" controls, high definition color touch screen, allowing the user to customize all major functions.4 cycles to choose from "Soft Chill" or "Soft Freeze" for delicate products, "Hard-Chill" or "Hard-Freeze" for large parts, timer control with bell at the end of...