%
Reinforced structure in tubular steel painted in aluminum color, withtransparent protective coating.Wooden base with anti-slip rubber protection.Wheels Ø 200 mm, two fixed and two swiveling.
%
Tubular chromium-plated steel structure.Chromium-plated wire basket.Two fixed wheels, Ø 200 mm, two swiveling wheels, Ø 125 mm.When it is not in use, trolleys can be fitted together to save space.
%
Tubular steel structure, Ø 40 mm, with chromium-platedfinishing and transparent protective coating.Carpeted color base "black".Edges protected by black rubber bumper strips.Wheels (Ø 160 mm), with two fixed and two swiveling with brakes.
%
Structuur in stalen buizen, Ø 40 mm, vergulde afwerking met een transparante laag.Tapijt in "zwarte" basis kleur.Randen die door zwarte rubberstroken worden beschermd.Wielen (Ø 160 mm), met 2 vaste en 2 draaiende met rem.
%
Thermopane®" external double-glazed windowsMade of lacquered sheet steel, CFC-free polyurethane insulation.AISI 304 stainless steel display, exposure depth 570 mm, height 790mm3 adjustable intermediate "tempered" glass shelves (1x 300 + 2x 350 mm), supporting structure in stainless steel AISI 304Service side 2 double-glazed "Thermopane®" sliding doors, vertical joints.Heating by electric resistancesMechanical thermostat, On/Off switch Device built in compliance with the standards (CE) in force.
%
Thermopane®" external double-glazed windowsMade of lacquered sheet steel, CFC-free polyurethane insulation.AISI 304 stainless steel display, exposure depth 570 mm, height 790mm3 adjustable intermediate "tempered" glass shelves (1x 300 + 2x 350 mm), supporting structure in stainless steel AISI 304Service side 2 double-glazed "Thermopane®" sliding doors, vertical joints.Heating by electric resistancesMechanical thermostat, On/Off switchDevice built in compliance with the standards (CE) in force.
%
Thermopane®" external double-glazed windowsMade of lacquered sheet steel, CFC-free polyurethane insulation.AISI 304 stainless steel display, exposure depth 570 mm, height 790mm3 adjustable intermediate "tempered" glass shelves (1x 300 + 2x 350 mm), supporting structure in stainless steel AISI 304Service side 2 double-glazed "Thermopane®" sliding doors, vertical joints.Heating by electric resistancesMechanical thermostat, On/Off switchDevice built in compliance with the standards (CE) in force.
%
Thermopane®" external double-glazed windowsMade of lacquered sheet steel, CFC-free polyurethane insulation.AISI 304 stainless steel display, exposure depth 570 mm, height 790mm3 adjustable intermediate "tempered" glass shelves (1x 300 + 2x 350 mm), supporting structure in stainless steel AISI 304Service side 2 double-glazed "Thermopane®" sliding doors, vertical joints.Heating by electric resistancesMechanical thermostat, On/Off switchDevice built in compliance with the standards (CE) in force.
%
Thermopane®" external double-glazed windowsMade of lacquered sheet steel, CFC-free polyurethane insulation.AISI 304 stainless steel display, exposure depth 570 mm, height 790mm3 adjustable intermediate "tempered" glass shelves (1x 300 + 2x 350 mm), supporting structure in stainless steel AISI 304Service side 2 double-glazed "Thermopane®" sliding doors, vertical joints.Heating by electric resistancesMechanical thermostat, On/Off switchDevice built in compliance with the standards (CE) in force.
%
Thermopane®" external double-glazed windowsMade of lacquered sheet steel, CFC-free polyurethane insulation.AISI 304 stainless steel display, exposure depth 570 mm, height 790mm3 adjustable intermediate "tempered" glass shelves (1x 300 + 2x 350 mm), supporting structure in stainless steel AISI 304Service side 2 double-glazed "Thermopane®" sliding doors, vertical joints.Heating by electric resistancesMechanical thermostat, On/Off switchDevice built in compliance with the standards (CE) in force.
%
Cooling capacity rendered 633 (W/f) for chamber volume 3,0 m³ / 3000 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are...
%
Cooling capacity rendered 824 (W/f) for chamber volume 5,0 m³ / 5000 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are...
%
Cooling capacity rendered 1258 (W/f) for chamber volume 10,2 m³ / 10200 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity rendered 1509 (W/f) for chamber volume 13,2 m³ / 13200 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity rendered 2313 (W/f) for chamber volume 27,8 m³ /27800 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity 2139 (W/f) for room volume 18,1 m³ / 18100 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard...
%
Cooling capacity 3490 (W/f) for room volume 34,3 m³ / 34300 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by thermostatic valve.Also equipped with a high pressure switch (fixed calibration) (C-PMAX-R). Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a...
%
Cooling capacity 981 (W/f) for room volume 6,2 m³ / 6200 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard with a high...
%
Cooling capacity 1800 (W/f) for room volume 14,9 m³ / 14900 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard with a...
%
%