Unit width 400 mm, small footprint.Cooling capacity 671 (W/f) for chamber volume 3,6 m³ / 3600 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Unit width 400 mm, small footprint.Cooling capacity 817 (W/f) for chamber volume 4,8 m³ / 4800 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Unit width 400 mm, small footprint.Cooling capacity 953 (W/f) for chamber volume 6,1 m³ / 6100 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Cooling capacity 1577 (W/f) for chamber volume 16,3 m³ / 16300 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 1914 (W/f) for chamber volume 19,4 m³ / 19400 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 2343 (W/f) for chamber volume 29,2 m³ / 29200 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 2547 (W/f) for chamber volume 34,2 m³ / 34200 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity rendered 1960 (W/f) for chamber volume 16,4 m³ / 16400 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice formation. Refrigerant gas...
%
Mechanical controls, mats manipulated by a lever arm.Base mounted version, 4 wheels, 2 fixed, 2 swivel wheels with brakes.Manual and pedal controls.Removable top flour bin.Removable tables.Lifting of safety grids assisted by pistons.1 speed1200x600 mm side tables (can be lifted or dismantled)Cylinder length 600 mmOpening of the cylinders from 0 - 50 mm, rolling diameter 80 mm.Travel speed 35 metres/minuteClosed overall dimensions 620x1060xh2050Standard: 2 stainless steel harvesting terminals,...
%
Mechanical controls, mats manipulated by a lever arm.Base mounted version, 4 wheels, 2 fixed, 2 swivel wheels with brakes.Manual and pedal controls.Removable top flour bin.Removable tables.Lifting of safety grids assisted by pistons.Variable speed (10 rpm to 60 rpm), with Inverter.1200x600 mm side tables (can be lifted or dismantled)Cylinder length 600 mmOpening of the cylinders from 0 - 50 mm, rolling diameter 80 mm.Travel speed 35 metres/minuteClosed overall dimensions...
%
Cooling capacity rendered 3389 (W/f) for chamber volume 37,6 m³ / 37600 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice formation. Refrigerant gas...
%
Unit width 400 mm, small footprint.Cooling capacity rendered 975 (W/f) for chamber volume 6 m³ / 6000 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice...
%
Unit width 400 mm, small footprint.Cooling capacity rendered 1302 (W/f) for chamber volume 10,6 m³ / 10600 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent...
%
Cast-iron plate, necessary measurements 365x255 mm.Stabilizing system in the upper plate, in order to keep the upper plate always in a horizontal position.Thermostat regulation up to 250°.
%
Plate in cast iron with ally for food, useful dimensions 225x255 mm.Stabilizing system in the top plate, allowing a constant horizontal position.Top plate handle in heatproof material.Heating resistances, situated under the cast iron plate.Regulation through thermostat till 250°C, together with a warning light.Structure in AISI 304 stainless steel.Adjustable lower legs.The equipment is manufactured following the (CE) standards in force
%
Plate in cast iron, useful dimensions 550x255 mm.Stabilizing system in the top plate, allowing a constant horizontal position.Regulation through thermostat till 250°C.
%
Upper plate gridlled, underplate flat all in vitroceramic.Easy maintenance working surface : 558 x 250 mm.Reception tub for liquids in front.Fitted with balanced springs on upper partRegulation thermostat till 250°C (from 20 till 200° in 4 min. till 300°C in 6 min). Low energy consumption.Chassis in stainless AISI 304.
%
Upper plate gridlled, underplate flat all in vitroceramic.Easy maintenance working surface : 370x250 mm.Reception tub for liquids in front.Fitted with balanced springs on upper partRegulation thermostat till 300°C (from 20 till 200° in 4 min. till 300°C in 6 min). Low energy consumption.Frame in stainless AISI 304.