Unit width 400 mm, small footprint.Cooling capacity 671 (W/f) for chamber volume 3,6 m³ / 3600 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Unit width 400 mm, small footprint.Cooling capacity 817 (W/f) for chamber volume 4,8 m³ / 4800 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Unit width 400 mm, small footprint.Cooling capacity 953 (W/f) for chamber volume 6,1 m³ / 6100 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Cooling capacity 1577 (W/f) for chamber volume 16,3 m³ / 16300 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 1914 (W/f) for chamber volume 19,4 m³ / 19400 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 2343 (W/f) for chamber volume 29,2 m³ / 29200 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Mechanical controls, joystick.Table version (very compact), 4 adjustable cylindersManual controls.1 speed.Side shelves of 500x500 mm.Cylinder length 500 mmRoll opening 0 - 36 mm, rolling diameter 60 mmTravel speed 35 metres/minute.Side shelves made of food-processed steel and allowing the product to slide.Precise regulation of the thickness of the dough sheet, constant production.Scrapers and supports made with specific materials (POM-C) for food use.Easy disassembly and reassembly of...
%
Cooling capacity 2547 (W/f) for chamber volume 34,2 m³ / 34200 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity rendered 1960 (W/f) for chamber volume 16,4 m³ / 16400 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice formation. Refrigerant gas...
%
Cooling capacity rendered 3389 (W/f) for chamber volume 37,6 m³ / 37600 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice formation. Refrigerant gas...
%
Unit width 400 mm, small footprint.Cooling capacity rendered 975 (W/f) for chamber volume 6 m³ / 6000 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice...
%
Unit width 400 mm, small footprint.Cooling capacity rendered 1302 (W/f) for chamber volume 10,6 m³ / 10600 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent...
%
Dimensions of the basin 306x510xh156 mm. Made of AISI 304 stainless steel, deep-drawn "top" (15/10 mm), levelling cylinders.Deep-drawn tank in AISI 316 stainless steel with rounded corners and double perforated bottom for draining food. GN capacity 1/1 h150 mm.Electric heating, vault with ceramic resistance placed above the appliance. ON/OFF switch with indicator light.Appliances built in compliance with current standards (CE).
%
Tank dimensions 306x510xh175 mm. Made of AISI 304 stainless steel, deep-drawn "top" (20/10 mm), levelling cylinders, waterproof "IPX5".Deep-drawn tank in AISI 316 stainless steel with rounded corners and double perforated bottom. GN capacity 1/1 h150 mm.Electric vault heating with ceramic resistance placed above the unit. ON/OFF switch.
%
- Useful tank dimensions 265x325xh150 mm.- Made of AISI 304 stainless steel. - AISI 304 18/10 stainless steel bowl with perforated bottom for draining food. - A vault with a ceramic resistor is placed above the appliance. ON/OFF switch. - The appliance is built in compliance with all current EC regulations.
%
Useful dimensions for the basin 325x530xh150 mm. Manufactured in stainless steel 18/10 AISI 304.Basin in stainless steel AISI 304 18/10 with perforated bottem which allows the abondant deep-frying oil to slink off.Equipped with a vault placed on top with an integrated ceramic resistance. ON/OFF switch.
%
Manufactured in stainless steel AISI 304.Electric heating by ceramic elements (infrared rays).ON/OFF switch.
%
- Dimensions tank 310x510xh180 mm.- Manufactured in stainless steel AISI 304, with adjustable feet in stainless steel- Top "pressed" with lateral edges.- Tank pressed stainless steel AISI 304 with perforated base.- Electric heating by armoured element in stainless steel, placed under the tank. Controlled temperature 30°C to 90°C by thermostat.
%
Tank 325x530xh150 mm.Designed for building-in 385x585 mmControl box delivered separately.Tank in stainless steel AISI 304, with perforated bottom for food draining.Vault with one ceramic element, put above the machine.ON/OFF switch, with indicator lamp.Manufactured in stainless steel AISI 304.