%
Flow rate (pressure 3 bar) hand shower 16 litres/minute.Non-return valve as standard (standard EN 1717 Belgaqua.)Wall bracket 150 mm1200 mm hand shower hose (DVGW standards).Single hole outlet Ø min.27/max.35, thread length 80 mm, hoses G 1/2 femaleMaximum pressure 6.5 bar and maximum temperature 65°C bar.
%
Made of chromium steel.Output one hole 3/4" (Ø 29 mm).Wall attachment 115 mm.Flexible 1200 mm length.Flow of the nozzle 16 liters/minute.
%
Helemaal uitgevoerd in roestvrij staal.Aan de basis is die bestemd voor deeg te kneden (inhoud kuip: 3 kg meel) en het automatisch produceren van harde tarwe deeg (8/10 kg/u).Mes voor het automatisch snijden van lange of korte pasta.Uitrusting voor de regeling van de snelheid.Geleverd met 4 matrijzen:n°7 (1,5 mm) voor taglionin°28 (6 mm) voor tagliateln°89 (10 mm) voor macaronispoglia 2x85 mm pasta bladen.Het apparaat is overeenkomstig met de "EG" richtlijnen voor veiligheid en...
%
Helemaal uitgevoerd in roestvrij staal.Aan de basis is die bestemd voor deeg te kneden (inhoud kuip: 3 kgmeel) en het automatisch produceren van harde tarwe deeg (8/10 kg/u).Mes voor het automatisch snijden van lange of korte pasta.Uitrusting voor de regeling van de snelheidGeleverd met 4 matrijzen:n°7 (1,5 mm) voor taglionin°28 (6 mm) voor tagliateln°89 (10 mm) voor macaronispoglia 2x85 mm pasta bladen,Het apparaat is overeenkomstig met de "EG" richtlijnen voor veiligheid en...
%
Made of chrome-plated brass.Output one hole 3/4" (Ø 29 mm).Wall attachment 135 mm.Flexible 1000 mm length.Flow of the nozzle 12 liters/minute.
%
Cooling capacity 586 (W/f) for chamber volume 2,8 m³ / 2800 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 895 (W/f) for chamber volume 5,7 m³ / 5700 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 1058 (W/f) for chamber volume 7,6 m³ / 7600 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 1733 (W/f) for chamber volume 17,3 m³ / 17300 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 2463 (W/f) for chamber volume 30,5 m³ / 30500 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity rendered 1881 (W/f) for chamber volume 15,7 m³ / 15700 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation,...
%
Cooling capacity rendered 2961 (W/f) for chamber volume 28,2 m³ / 28200 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation,...
%
Cooling capacity rendered 1072 (W/f) for chamber volume 7,1 m³ / 7100 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation, as...
%
Cooling capacity rendered 1288 (W/f) for chamber volume 9,5 m³ / 9500 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation, as...