Arbeitsplatte aus Edelstahl AISI 304. Rahmen aus kunststoffbeschichtetem Stahlblech, verstellbare Edelstahlfüße (gleitend) ermöglichen eine perfekte Anpassung (auf Wunsch: AP = mit Plattformträger "Servicetritt" oder SP = Standard ohne Gerät).Rohversion (ohne dekorative Frontplatte, ohne Verbindungen, Sockelleisten....)Das Gerät ist nach den aktuellen CE-Normen gebaut.
%
%
Interior volume (gross) 1250 liters.Internal dimensions: 740x920xh1850 mm.For trolley GN2/1 (or) EN 600x800 Max. Height 1830mm (not included).Refrigerant gas R290.Interior and exterior made of stainless steel (food grade) AISI 304 (rear galvanized steel), monocoque frameFlat floor in AISI 304 stainless steel, rounded corners and corners (without rough edges)Door with ergonomic (not protruding) and reversible handle, closing by "triple chamber" and magnetic seal (easy replacement, without...
%
Interior volume (gross) 2500 liters.Internal dimensions 1640x920xh1850 mm.For trolley GN2/1 (or) EN 600x800 Max. Height 1830mmNB: trolley not included.Refrigerant gas R290.Interior and exterior made of stainless steel (food grade) AISI 304 (rear galvanized steel), monocoque frameFlat floor in AISI 304 stainless steel, rounded corners and corners (without rough edges)Door with ergonomic (not protruding) and reversible handle, closing by "triple chamber" and magnetic seal (easy replacement,...
%
Interior volume (gross) 1250 liters.2 doors, 1 "pass-through" on each side.Internal dimensions: 740x920xh1850 mm.For trolley GN2/1 (or) EN 600x800 Max. Height 1830mmNB: trolley not included.Refrigerant gas R290.Interior and exterior made of stainless steel (food grade) AISI 304 (rear galvanized steel), monocoque frameFlat floor in AISI 304 stainless steel, rounded corners and corners (without rough edges)Door with ergonomic (not protruding) and reversible handle, closing by "triple chamber"...
%
%
%
%
%
%
%
%
%
Cooling capacity 586 (W/f) for chamber volume 2,8 m³ / 2800 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 895 (W/f) for chamber volume 5,7 m³ / 5700 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 1058 (W/f) for chamber volume 7,6 m³ / 7600 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 1733 (W/f) for chamber volume 17,3 m³ / 17300 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 2463 (W/f) for chamber volume 30,5 m³ / 30500 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...