Tilting head and removable bowl.2 Speeds (Spiral : 1st speed 100 rpm. and 2nd speed 200rpm) & (Tank : 1st speed 10rpm. and 2nd speed 20rpm and timer) with possibility of automatic or manual programming with timer or continuous.Diameter of the spiral 24 mm.Diameter of the tank 500 mm height 270 mm (53 liters) = 44 kg dough.Digital control panel (manual or automatic operation)Frame made of painted steel.Rotating tank in AISI 304 stainless steel.High hardness stainless steel spiral...
%
%
Removable bowl and tilting head.2 Speeds.Standard with timer.Diameter of the bowl 500 mm, (53 liters) = 44 kg dough. Structure made of painted steel.Rotating cockpit in stainless steel AISI 304.Spiral in stainless steel fusion high strength divisor in stainless steel AISI 304.Grid in stainless steel equipped with a security microswitch.Oil transmission/gear box, for more reliability and low sound emission!!Engine suspended, better ventilation, easier maintenance.Low voltage control 24 V...
%
Removable bowl and tilting head.2 Speeds.Standard with timer.Diameter of the bowl 500 mm, (53 liters) = 44 kg dough. Structure made of painted steel.Rotating cockpit in stainless steel AISI 304.Spiral in stainless steel fusion high strength divisor in stainless steel AISI 304.Grid in stainless steel equipped with a security microswitch.Oil transmission/gear box, for more reliability and low sound emission!!Engine suspended, better ventilation, easier maintenance.Low voltage control 24 V...
%
Removable bowl and tilting head.2 Speeds.Standard with timer.Diameter of the bowl 500 mm, (53 liters) = 44 kg dough. Structure made of painted steel.Rotating cockpit in stainless steel AISI 304.Spiral in stainless steel fusion high strength divisor in stainless steel AISI 304.Grid in stainless steel equipped with a security microswitch.Oil transmission/gear box, for more reliability and low sound emission!!Engine suspended, better ventilation, easier maintenance.Low voltage control 24 V...
%
Removable bowl and tilting head.2 Speeds.Standard with timer.Diameter of the bowl 500 mm, (53 liters) = 44 kg dough. Structure made of painted steel.Rotating cockpit in stainless steel AISI 304.Spiral in stainless steel fusion high strength divisor in stainless steel AISI 304.Grid in stainless steel equipped with a security microswitch.Oil transmission/gear box, for more reliability and low sound emission!!Engine suspended, better ventilation, easier maintenance.Low voltage control 24 V...
%
Cooling capacity rendered 633 (W/f) for chamber volume 3,0 m³ / 3000 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are...
%
Cooling capacity rendered 824 (W/f) for chamber volume 5,0 m³ / 5000 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are...
%
Cooling capacity rendered 1258 (W/f) for chamber volume 10,2 m³ / 10200 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity rendered 1509 (W/f) for chamber volume 13,2 m³ / 13200 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity rendered 2313 (W/f) for chamber volume 27,8 m³ /27800 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity 2139 (W/f) for room volume 18,1 m³ / 18100 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard...
%
Cooling capacity 3490 (W/f) for room volume 34,3 m³ / 34300 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by thermostatic valve.Also equipped with a high pressure switch (fixed calibration) (C-PMAX-R). Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a...
%
Cooling capacity 981 (W/f) for room volume 6,2 m³ / 6200 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard with a high...
%
Cooling capacity 1800 (W/f) for room volume 14,9 m³ / 14900 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard with a...
%
Produces 155 kg per 24 hours, storage in plastic, capacity 65 kg.18 g ice cubesAir condenser."Spray" system with brass nozzles, (designed to prevent the magnetization of limestone).Tropicalized hermetic unit ambient temperature + 43 ° CRefrigerant gas R404a or R452a, air-cooled condenser.Manufactured in stainless steel AISI 304, adjustable feet.The equipment is manufactured following the (CE) standards in force.
%
Produces 24 kg per 24 hours, recessed version, Reserve in ABS (polyurethane insulation), capacity 4 kg.Air condenser."Spray" system with brass nozzles, (designed to prevent the magnetization of limestone).Tropicalized hermetic unit ambient temperature + 43 ° CRefrigerant gas R404a or R452a, air-cooled condenser.Manufactured in stainless steel AISI 304, adjustable feet.The equipment is manufactured following the (CE) standards in force.