Realisation in anodized aluminium, base in stainless steel.Automatic or manual cutting.Programmation of the cutting from 10 to 50 slices or continuous.Blade in stainless steel AISI 304, automatic sharpening.Blade protection easy to remove.Cut capacity 245x300 mm, cut adjustment from 0 to15 mm, trajectory of carriage 330 mm, plate 270x260 mm.Low tension control 24 V.Belt drive.
%
Realisation in anodized aluminium, base in stainless steel.Automatic or manual cutting.Programmation of the cutting from 10 to 50 slices or continuous.Blade in stainless steel AISI 304, automatic sharpening.Blade protection easy to remove.Cut capacity 245x300 mm, cut adjustment from 0 to15 mm, trajectory of carriage 330 mm, plate 270x260 mm.Low tension control 24 V.Belt drive.
%
For each and every product such as ham, sausage, raw meat, cheese.Automatic carriage motion with variable speed control (it can be used manually as well).Independent controls for carriage motion and blade.Exclusive designed carriage with a special end weight and an adjustable vertical product fence to provide stability and advance products evenly.Stainless steel base.Oblique blade, 35° inclination (a blade extractor comes standard).Max. cutting capacity: 270xh230 (Ø 255 mm), slice thickness:...
%
Vertical, straight-blade slicer.Double-feed carriage with a clamping arm holding firmly in place all types of hams and cold meats.Max. cutting capacity: 270xh250 (Ø 250 mm), slice thickness: 0-30 mm.50 mm gap between blade and body. Sturdy, stylish and performing, sanitary polished and anodized aluminium alloy, hardened, chromed stainless blade, permanent tapered blade ring guard and interlocked blade guard (100% safe).Reinforced gauge plate, removable slider guard.A maintenance Kit comes...
%
Gravity-feed, 38° inclination (a blade extractor comes standard).Max. cutting capacity 270xh230 (Ø 255 mm), slice thickness: 0-30 mm.50 mm gap between blade and body. Stylish and performing, sanitary polished and anodized aluminium alloy, hardened, chromed stainless blade, permanent tapered blade ring guard and interlocked blade guard (100% safe).Reinforced gauge plate, removable slider guard.Carriage sliding on stainless bearings for an easy and quiet operation, polished, chromed and...
%
Self-lubricating, endless screw in oil-bath gear drive.Gravity-feed 35° inclination (a blade extractor comes standard).Max. cutting capacity 270xh230 (Ø 255 mm), slice thickness 0-30 mm.50 mm gap between blade and body. Elegant and efficient, made of anodized and polished aluminium alloy melting.Hardened, chrome-plated and rectified steel blade, fixed protection ring and blade cover with microswitch (100% safe).Reinforced stop, protection of the stop slide, removable.Carriage on stainless...
%
Large flow rate, for large distribution.German oblique blade "Grund & Bunse", inclination at 35°.Precise opening movement of the blade over the first 3 mm.Max. cutting capacity: 307xh220 mm (Ø 250 mm), thickness 0-24 mm.49 mm space between blade and frame. Compact, robust, elegant and efficient, made of cast anodized and polished aluminium alloy.Hardened, chrome-plated and ground steel blade, fixed protection ring and blade cover with microswitch (100% secure).Reinforced stop, protection...
%
Vertical, straight-blade slicer.Double-feed carriage for slicing large joints of raw meat.Max. cutting capacity: 250xh245 (Ø 245 mm), slice thickness: 0-30 mm.50 mm gap between blade and motor. Sturdy, stylish and performing, sanitary polished and anodized aluminium alloy, hardened, chromed stainless blade, permanent tapered blade ring guard and interlocked blade guard (100% safe).Reinforced gauge plate, removable slider guard.A maintenance Kit comes standard (incl. blade extractor).Carriage...
%
Capacity 5 baskets 500x500mm, spacing between baskets 300mmStainless steel tubular structure, section 20x20mm.Stainless steel sheet guides in "L" shape.Grey rubber bumpers at the corners.Swivel castors, diam. 125mm.
%
Cooling capacity rendered 633 (W/f) for chamber volume 3,0 m³ / 3000 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are...
%
Cooling capacity rendered 824 (W/f) for chamber volume 5,0 m³ / 5000 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are...
%
Cooling capacity rendered 1258 (W/f) for chamber volume 10,2 m³ / 10200 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity rendered 1509 (W/f) for chamber volume 13,2 m³ / 13200 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity rendered 2313 (W/f) for chamber volume 27,8 m³ /27800 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity 2139 (W/f) for room volume 18,1 m³ / 18100 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard...
%
Cooling capacity 3490 (W/f) for room volume 34,3 m³ / 34300 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by thermostatic valve.Also equipped with a high pressure switch (fixed calibration) (C-PMAX-R). Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a...
%
Cooling capacity 981 (W/f) for room volume 6,2 m³ / 6200 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard with a high...
%
Cooling capacity 1800 (W/f) for room volume 14,9 m³ / 14900 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard with a...