High version, easier loading / unloading of baskets,..."Double-walled" Standard version Load height 405 mmplate height 380 mm From 60 till 24 baskets/hour, cycles 60'' - 120'' - 150" or continuousRotating wash and rinse arms (upper and lower), lower in stainless steelSelf-cleaning jetsTank (23 Lt., 2,1 kW) with rounded edges, "stamped" bottom"Stamped" double walled door, "removable" gasketRemovable control panelAutomatic filling of the tankCheck valveHot water rinse (2,5 Lt. water consumption...
%
Low version, installation option under sinks and cupboards etc...."Double-walled" VersionLoad height 405 mmPlate height 380 mm From 60 till 24 baskets/hour, cycles 60'' - 120'' - 150" or continuousRotating wash and rinse arms (upper and lower), lower in stainless steelSelf-cleaning jetsTank (23 Lt., 2,1 kW) with rounded edges, "stamped" bottom"Stamped" double walled door, "removable" gasketRemovable control panelAutomatic filling of the tankCheck valveHot water rinse (2,5 Lt. water...
%
General characteristics:AISI 304 stainless steel finish, between 12/10 mm and 30/10 mm thick, double cavity for better thermal and acoustic insulation (-60dB), adjustable stainless steel feet.Linear or angular implantations with left and right entries.Traction system with parallel stainless steel bars.Automatic advance system with 3 speeds.Ability to perform a continuous, basket-by-basket or delayedwash."Reversible" traction system, right left entry.Counter balanced wide opening doors with...
%
%
%
%
Unit width 400 mm, small footprint.Cooling capacity 671 (W/f) for chamber volume 3,6 m³ / 3600 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Unit width 400 mm, small footprint.Cooling capacity 817 (W/f) for chamber volume 4,8 m³ / 4800 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Unit width 400 mm, small footprint.Cooling capacity 953 (W/f) for chamber volume 6,1 m³ / 6100 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Cooling capacity 1577 (W/f) for chamber volume 16,3 m³ / 16300 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 1914 (W/f) for chamber volume 19,4 m³ / 19400 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 2343 (W/f) for chamber volume 29,2 m³ / 29200 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 2547 (W/f) for chamber volume 34,2 m³ / 34200 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity rendered 1960 (W/f) for chamber volume 16,4 m³ / 16400 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice formation. Refrigerant gas...
%
Cooling capacity rendered 3389 (W/f) for chamber volume 37,6 m³ / 37600 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice formation. Refrigerant gas...
%
Unit width 400 mm, small footprint.Cooling capacity rendered 975 (W/f) for chamber volume 6 m³ / 6000 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice...
%
Unit width 400 mm, small footprint.Cooling capacity rendered 1302 (W/f) for chamber volume 10,6 m³ / 10600 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent...
%
Realisation "double walled". with thermic insulation.Watersoftener continuously, incorporated (WARNING: connection to cold water).Charging height diam. 465 mm.Standard rinsing pump (atmospheric boiler). Control panel at the top of the hood, digital display.Basket 600x500 mm, capacity 22 plates, dishes 600x400 (see accessories), beer baskets 600x400 to 135 Lt, always the possibility of using 500x500 mm baskets. 3 cycles: 60 '- 110' - 150 '' or continuous.Device opening and closing cover on...
%
Realization in "double walls" with thermal insulationIntegration of the "Green System H.R.S. Condenser-recovery of vapors, great energy saving (ATTENTION: connection to cold water)Continuous water softener, incorporated (ATTENTION: connection to cold water)Loading height 465 mmStandard flush pump (atmospheric boiler). Control panel on top of the cover, digital displayBasket 600x500 mm, capacity 22 plates, plates 600x400 (see accessory), beer baskets 600x400 up to 135 Lt, still possible to use...
%
%
%
%
%