Unit width 400 mm, small footprint.Cooling capacity 671 (W/f) for chamber volume 3,6 m³ / 3600 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Unit width 400 mm, small footprint.Cooling capacity 817 (W/f) for chamber volume 4,8 m³ / 4800 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Unit width 400 mm, small footprint.Cooling capacity 953 (W/f) for chamber volume 6,1 m³ / 6100 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Cooling capacity 1577 (W/f) for chamber volume 16,3 m³ / 16300 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 1914 (W/f) for chamber volume 19,4 m³ / 19400 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 2343 (W/f) for chamber volume 29,2 m³ / 29200 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 2547 (W/f) for chamber volume 34,2 m³ / 34200 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity rendered 1960 (W/f) for chamber volume 16,4 m³ / 16400 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice formation. Refrigerant gas...
%
Cooling capacity rendered 3389 (W/f) for chamber volume 37,6 m³ / 37600 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice formation. Refrigerant gas...
%
Unit width 400 mm, small footprint.Cooling capacity rendered 975 (W/f) for chamber volume 6 m³ / 6000 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice...
%
Unit width 400 mm, small footprint.Cooling capacity rendered 1302 (W/f) for chamber volume 10,6 m³ / 10600 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent...
%
Capacity 10 levels GN 2/1 (or 20x GN 1/1).Upper part with stainless steel gallery on 3 sides. Construction in austenitic stainless steel (food).Walls and door made of double injected prey (high density CFC-free polyurethane).Door opening at 120°, with vertical latch and key lock, with a seal in the door frame, easily replaceable without tools.Hinges with stop at 100°, closing with automatic return, avoiding heat loss.Possibility of using GN 2/1 or GN 1/1 spacing 60 mm.Heating by resistances...
%
Capacity 20 GN 2/1 levels (or 40x GN 1/1). Construction in austenitic stainless steel (food).Walls and door made of double injected prey (high density CFC-free polyurethane).Door opening at 120°, with vertical latch and key lock, with a seal in the door frame, easily replaceable without tools.Hinges with stop at 100°, closing with automatic return, avoiding heat loss.Possibility of using GN 2/1 or GN 1/1 spacing 60 mm.Heating by resistances and pulsed air, homogeneity of the temperature...
%
Capacity 40 GN 2/1 levels (or 80x GN 1/1).SPECIAL BANQUETING: Standard 20 grids to optimize space inside the trollley.Up to eight (8) plates with a diameter of 300 mm can be stored per level, for a total of 160 plates. Construction in austenitic stainless steel (food).Walls and door made of double injected prey (high density CFC-free polyurethane).Door opening at 120°, with vertical latch and key lock, with a seal in the door frame, easily replaceable without tools.Hinges with stop at 100°,...
%
Inside volume: 122 liters.Inside dimensions: 508x355xh720 mm.Load capacity: 161 cans (33 cl.) or 84 bottles (33 cl.).1 swingdoor on hinges, (reversible).Included: 2 grids 498x335 mm.Cooling R600a.Glass door(s), double glazing, "Thermopane"®.Closure by keys.Interior lighting type LED.Included: for each door, 2 adjustable shelves and removable height.Built-in compressor unit climatic class 4 (30°C & 55% HR).Sound level 45 db (A).Electronic regulation, digital display T ° + 2 ° + 10...
%
Energy efficiency class: A.Inside volume: 122 liters.Inside dimensions: 508x355xh720 mm.Load capacity: 161 cans (33 cl.) or 84 bottles (33 cl.).1 hinged door (reversible).Included: 2 grids 498x335 mm.Refrigerant: R600a. Low energy consumption components.Glass door(s), double-glazed "Thermopane".Locking device with keys.Interior LED lighting.Included: For each door, 2 removable and height-adjustable grids.Built-in compressor unit, climate class 4 (30°C & 55% RH).Noise level: 45 dB...