2 professional magnetrons, for intensive use. Digital controls, 30 storable "programs" with self-diagnostic device, 5 power levels. Preset key for 20-second use (at the highest power). Outgoing power 1500 W. Easy cleaning of the aeration filter. Interior dimensions : 370x370xh190 mm. Contents 26 liters. Stackable units. Interior and exterior manufactured in stainless steel.
%
2 professional magnetrons, for intensive use. Digital controls, 30 storable "programs" with self-diagnostic device, 5 power levels. Preset key for 20-second use (at the highest power). (Outgoing) power 1850 W. Easy cleaning of the aeration filter. Interior dimensions : 370x370xh190 mm. Contents 26 liters. Stackable units. Interior and exterior manufactured in stainless steel.
%
%
2 professional magnetrons, for intensive use Internal LED lightingDigital controls, 50 "memorizable" programs with self-diagnosis device, 5 power levelsPre-programmed button for use during 20 seconds (at the highest power)Output power (rendered) 1500 WEasy cleaning of the ventilation filterInternal dimensions: 370x370xh190 mmContent 26 liters Stackable appliances Interior and exterior stainless steel construction
%
2 professional magnetrons, for intensive use Internal LED lightingDigital controls, 50 "memorizable" programs with self-diagnosis device, 5 power levelsPre-programmed button for use during 20 seconds (at the highest power)Output power (rendered) 1850 WEasy cleaning of the ventilation filterInternal dimensions: 370x370xh190 mm Content 26 liters Stackable appliances Interior and exterior stainless steel construction
%
Output power 1400 W1 magnetron (under the base of the oven) for professional useDigital control panel: 5 power levels, timer (0 to 60 minutes) with sound signal at the end of the cycle (10 presets from 0:10 seconds to 5:00 minutes) and a "X2" push-button for multiple portions, Stop and Start buttons and visual displaySelf-diagnostic device in case of anomalies.100 "storable" programs.Capacity 34 liters, with the possibility of using GN 2/3, 1/2, 1/3, 1/4 ... dishes up to ø 350 mmInterior...
%
Output power (rendered) 2100 W2 magnetrons (1 on the vault, 1 under the bottom of the oven), for very intensive professional use!Digital control panel: 5 power levels, timer (from 0 to 60 minutes) with acoustic signal at the end of the cycle (10 presets from 0:10 seconds to 3:30 minutes) as well as a "X2" button multiple portions, Stop & Start buttons and display displaySelf-diagnosis device in case of anomalies.100 "memorizable" programsIntermediate shelf in treated glass (removable) as...
%
Cooling capacity 586 (W/f) for chamber volume 2,8 m³ / 2800 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 895 (W/f) for chamber volume 5,7 m³ / 5700 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 1058 (W/f) for chamber volume 7,6 m³ / 7600 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 1733 (W/f) for chamber volume 17,3 m³ / 17300 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 2463 (W/f) for chamber volume 30,5 m³ / 30500 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity rendered 1881 (W/f) for chamber volume 15,7 m³ / 15700 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation,...
%
Cooling capacity rendered 2961 (W/f) for chamber volume 28,2 m³ / 28200 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation,...
%
Cooling capacity rendered 1072 (W/f) for chamber volume 7,1 m³ / 7100 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation, as...
%
Cooling capacity rendered 1288 (W/f) for chamber volume 9,5 m³ / 9500 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation, as...