Cooling capacity 1577 (W/f) for chamber volume 16,3 m³ / 16300 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Monoblock unit, climate class 4 (30°C Temperature & 55% Humidity), equipped with 2 side handles (easily removable), ventilated condenser.Ventilated evaporator treated against the salt and the food acids.Refrigerant gas R455a.Programmable electronic regulator, display on front with blue LED.Automatic defrosting by reversal of cycle (programmable as one pleases), automatic evaporation of the condensate.Appliances are complied with the CE in force.
%
%
Monoblock unit, climate class 5 (40°C Temperature & 40% Humidity), equipped with 2 side handles (easily removable), ventilated condenser.Ventilated evaporator treated against the salt and the food acids.Refrigerant gas R455a.Programmable electronic regulator, display on front with blue LED.Automatic defrosting by reversal of cycle (programmable as one pleases), automatic evaporation of the condensate.Appliances are complied with the CE in force.
%
Cooling capacity 1914 (W/f) for chamber volume 19,4 m³ / 19400 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
%
Cooling capacity 2343 (W/f) for chamber volume 29,2 m³ / 29200 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 2547 (W/f) for chamber volume 34,2 m³ / 34200 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
%
%
Cooling capacity rendered 1960 (W/f) for chamber volume 16,4 m³ / 16400 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice formation. Refrigerant gas...
%
Cooling capacity rendered 3389 (W/f) for chamber volume 37,6 m³ / 37600 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice formation. Refrigerant gas...
%
Unit width 400 mm, small footprint.Cooling capacity rendered 975 (W/f) for chamber volume 6 m³ / 6000 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice...
%
Unit width 400 mm, small footprint.Cooling capacity rendered 1302 (W/f) for chamber volume 10,6 m³ / 10600 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent...
%
%
Interior volume 9831 liters.Useful passage 720xh1860 mm. Galvanized steel panel recovered with a non-toxic plastic white film, food quality, polyurethane insulation injected at high density, eco-friendly (without CFC).Thickness of the wall, floor and ceiling = 100 mm.Locking of the panel by built-in "eccentric-gear" hooks.Anti-slip stainless steel floor.The angles and the corners of the floor, the ceiling and the walls are all at 135°, "sanitary".Very strong "bulging" door, reversible,...
%
Interior volume 10182 liters.Useful passage 720xh1860 mm. Galvanized steel panel recovered with a non-toxic plastic white film, food quality, polyurethane insulation injected at high density, eco-friendly (without CFC).Thickness of the wall, floor and ceiling = 100 mm.Locking of the panel by built-in "eccentric-gear" hooks.Anti-slip stainless steel floor.The angles and the corners of the floor, the ceiling and the walls are all at 135°, "sanitary".Very strong "bulging" door, reversible,...
%
Interior volume 11434 liters.Useful passage 720xh1860mm Galvanized steel panel recovered with a non-toxic plastic white film, food quality, polyurethane insulation injected at high density, eco-friendly (without CFC).Thickness of the wall, floor and ceiling = 80 mm.Locking of the panel by built-in "eccentric-gear" hooks.Anti-slip stainless steel floor.The angles and the corners of the floor, the ceiling and the walls are all at 135°, "sanitary".Very strong "bulging" door, reversible,...
%
Interior volume 11610 liters.Useful passage 720xh1860mm Galvanized steel panel recovered with a non-toxic plastic white film, food quality, polyurethane insulation injected at high density, eco-friendly (without CFC).Thickness of the wall, floor and ceiling = 80 mm.Locking of the panel by built-in "eccentric-gear" hooks.Anti-slip stainless steel floor.The angles and the corners of the floor, the ceiling and the walls are all at 135°, "sanitary".Very strong "bulging" door, reversible,...
%
Interior volume 13037 liters.Useful passage 720xh1860 mm. Galvanized steel panel recovered with a non-toxic plastic white film, food quality, polyurethane insulation injected at high density, eco-friendly (without CFC).Thickness of the wall, floor and ceiling = 100 mm.Locking of the panel by built-in "eccentric-gear" hooks.Anti-slip stainless steel floor.The angles and the corners of the floor, the ceiling and the walls are all at 135°, "sanitary".Very strong "bulging" door, reversible,...