Frame in galvanized steel.Soundproof isolation.
%
Frame in galvanized steel.Soundproof isolation.
%
Frame in galvanized steel.Soundproof isolation.
%
Frame in galvanized steel.Soundproof isolation.
%
Frame in galvanized steel.Soundproof isolation.
%
Frame in galvanized steel.Soundproof isolation.
%
Frame in galvanized steel.Soundproof isolation.
%
Profile frame in aluminium.Panels with isolated double wall.Lateral inspection.Ventilator with direct suction.3 double filtering.
%
Profile frame in aluminium.Panels with isolated double wall.Lateral inspection.Ventilator with direct suction.3 double filtering.
%
Chambers: 2x 620x500x120 mm.Thermostatic control of the two chambers by 3 thermostats.Front side aesthetics "RUSTIQUE", made in high temperature painted steel, chassis in painted sheet.Chamber with top stainless steel arcade, avoiding the heat from going out when opening the door.Galvanised steel chamber, bottom in "special" refractory material.Door with heatless handle.Inner chamber light (except E3F/24R).Heating by top and bottom electric armoured elements, setting by thermostats (50 to...
%
Flow rate: 3000 m³/o. (Pressure drop 380 Pa). Centrifugal double-inlet ventilation units with built-in motor (operating temperature/resistance: -20° to 40°).Enclosed motor, IP54 protection rating.Galvanized steel casing with 5 mm internal sound insulation (polyurethane foam).Side inspection for after-sales service (S.A.V.).
%
Flow rate: 4500 m³/o. (Pressure drop 220 Pa). Centrifugal double-inlet ventilation units with built-in motor (operating temperature/resistance: -20° to 40°).Enclosed motor, IP54 protection rating.Galvanized steel casing with 5 mm internal sound insulation (polyurethane foam).Side inspection for after-sales service (S.A.V.).
%
Flow rate: 1300 m³/o. (Pressure drop 200 Pa). Centrifugal double-inlet ventilation units with built-in motor (operating temperature/resistance: -20° to 40°).Enclosed motor, IP54 protection rating.Galvanized steel casing with 5 mm internal sound insulation (polyurethane foam).Side inspection for after-sales service (S.A.V.).
%
2 chambers 720x720xx150 mm (5,3 kW)2x 4 pizzas od diam. 350 mm (or) 2x 1 pizza of diam. 500 mm2 ovens superposable (8+4)Stainless steel chamber, bottom in refractory stone.Electric evacuation valve, for smokes - steams."Halogenous" lighting, built-in, "high T°".Offset door, "panoramic" porthole in safety glass.Heating by shielded electric elements in stainless steel, placed under the bottom and on the vault of the oven, stainless steel arch avoiding temperature drop while opening the...
%
Flow rate: 2500 m³/o. (Pressure drop 210 Pa). Centrifugal double-inlet ventilation units with built-in motor (operating temperature/resistance: -20° to 40°).Enclosed motor, IP54 protection rating.Galvanized steel casing with 5 mm internal sound insulation (polyurethane foam).Side inspection for after-sales service (S.A.V.).
%
%
Single-Phase Version.Pre-cut air inlet with a diameter of 250 mm.Airflow: 2200 m³/h (pressure drop: 200 Pa). Centrifugal single-inlet ventilation units with built-in motor (operating temperature/resistance: -20° +110°).Aluminum profiles and cladding panels made of galvanized "sandwich" type sheets with 20mm acoustic insulation (polyurethane foam).Panel with handle for easy access to the impeller for maintenance.Open motor access area for after-sales service inspection.Closed motor, IP54...
%
Single-Phase Version.Pre-cut air inlet with a diameter of 250 mm.Airflow: 3200 m³/h (pressure drop: 200 Pa). Centrifugal single-inlet ventilation units with built-in motor (operating temperature/resistance: -20° +110°).Aluminum profiles and cladding panels made of galvanized "sandwich" type sheets with 20mm acoustic insulation (polyurethane foam).Panel with handle for easy access to the impeller for maintenance.Open motor access area for after-sales service inspection.Closed motor, IP54...
%
Single-Phase Version.Pre-cut air inlet with a diameter of 315 mm.Airflow: 4200 m³/h (pressure drop: 200 Pa). Centrifugal single-inlet ventilation units with built-in motor (operating temperature/resistance: -20° +110°).Aluminum profiles and cladding panels made of galvanized "sandwich" type sheets with 20mm acoustic insulation (polyurethane foam).Panel with handle for easy access to the impeller for maintenance.Open motor access area for after-sales service inspection.Closed motor, IP54...
%
Single-Phase Version.Pre-cut air inlet with a diameter of 350 mm.Airflow: 5600 m³/h (pressure drop: 200 Pa). Centrifugal single-inlet ventilation units with built-in motor (operating temperature/resistance: -20° +110°).Aluminum profiles and cladding panels made of galvanized "sandwich" type sheets with 20mm acoustic insulation (polyurethane foam).Panel with handle for easy access to the impeller for maintenance.Open motor access area for after-sales service inspection.Closed motor, IP54...
%
%
Version 8 drawers GN 1/1 (maximum height 100 mm).2 ventilated evaporators "treaty".6 adjustable stainless steel feet. Monocoque designInside and outside (top included) manufactured in stainless steel AISI 441 (also the back).Stamped interior bottom, rounded angles and corners (without roughness).Drawers with ergonomic handle, on telescopic slides, "snap-fit" closure by magnetic joint (easy replacement without tools).Compressor unit climate class 4 (30°C Temperature & 55% Humidity), ),...
%
Version 8 drawers GN 1/1 (max. load Height 110 mm).2 ventilated evaporators "treaty".6 adjustable stainless steel feet. Monocoque design.Inside and outside (top included) manufactured in stainless steel AISI 304 (also the back).Stamped interior bottom, rounded angles and corners (no rough edges).Drawers with ergonomic handles, on telescopic runners, closed by magnetic pressure seals (easy replacement, no tools required).Class 5 compressor unit (40°C Temperature & 40% Humidity), built into...