Unit width 400 mm, small footprint.Cooling capacity 671 (W/f) for chamber volume 3,6 m³ / 3600 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Unit width 400 mm, small footprint.Cooling capacity 817 (W/f) for chamber volume 4,8 m³ / 4800 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Unit width 400 mm, small footprint.Cooling capacity 953 (W/f) for chamber volume 6,1 m³ / 6100 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Cooling capacity 1577 (W/f) for chamber volume 16,3 m³ / 16300 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 1914 (W/f) for chamber volume 19,4 m³ / 19400 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 2343 (W/f) for chamber volume 29,2 m³ / 29200 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 2547 (W/f) for chamber volume 34,2 m³ / 34200 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity rendered 1960 (W/f) for chamber volume 16,4 m³ / 16400 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice formation. Refrigerant gas...
%
Cooling capacity rendered 3389 (W/f) for chamber volume 37,6 m³ / 37600 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice formation. Refrigerant gas...
%
Unit width 400 mm, small footprint.Cooling capacity rendered 975 (W/f) for chamber volume 6 m³ / 6000 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice...
%
Unit width 400 mm, small footprint.Cooling capacity rendered 1302 (W/f) for chamber volume 10,6 m³ / 10600 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent...
%
Charging height glasses 250 mm. 30 baskets/hour,120-second cycle.Rotating wash (lower) and rinse arms (upper and lower).Self-cleaning sprinklers.Tank, rounded edges (7 Lit., 0,6 kW).Stamped walls.Double walled door.Removable control panel.Automatic filling of the tank.Check valve.Hot water rinse (water consumption per cycle 2 liters), boiler (pressure) in stainless steel (2 Lit., 2,6 kW).Micro switch, when the door opens.Safety thermostat.Manufactured in stainless steel AISI 304.Standard: 2...
%
4 mm vitro , useful surface 342x425 mm.Double coil 180 and 280 mm (with automatic selection according to the diameter of the pan).Function "Booster" total power (3600 W) across the double inductor.Regulation of 12 positions from 50 W to 3600 W.Black vitroceramic, high temperature, 100% waterproof."Built-In" casing in stainless steel AISI 304 (30/10th).Glass touch control panel (detects the presence of finger), manual power setting with On-Off button. 12 positions, 3 preset power buttons...
%
6 mm vitro, useful surface 342x425 mm.Coil 230 mm.Regulation of 12 positions from 100 W to 3600 W.Single-voltage 400/3N (not switchable).Black vitroceramic, high temperature, 100% waterproof."Built-In" casing in stainless steel AISI 304 (30/10th).Glass touch control panel (detects the presence of finger), manual power setting with On-Off button. 12 positions, 3 preset power buttons (6/10/12), timer 0-99 minutes, visual display and acoustic signals.Standart washable filter delivered.Important...
%
%
6 mm vitro, useful surface 342x425 mm.Coil 230 mm.Regulation of 12 positions from 100 W to 6000 W.Single-voltage 400/3N (not switchable).Black vitroceramic, high temperature, 100% waterproof."Built-In" casing in stainless steel AISI 304 (30/10th).Glass touch control panel (detects the presence of finger), manual power setting with On-Off button. 12 positions, 3 preset power buttons (6/10/12), timer 0-99 minutes, visual display and acoustic signals.Standart washable filter delivered.Important...
%
Production per tank: 25kg/h in pre-cooking 50kg/h in cooking.3 tanks 13liters Ø 360 mm (3x 16,16 kW).3 swing doors.Standard equipment : 1 cover in stainless steel per tank.Top superior very thick (20/10éme), welded.Top for emptying lower for each tank and drain tray (or filtration) with removable spout (easy to use in complete safety).Upper tray for cooked food, with a perforated bottom for dripping.Swing doors with double walls and isolated.Heating by circular cast iron burner with very high...