Unit width 400 mm, small footprint.Cooling capacity 671 (W/f) for chamber volume 3,6 m³ / 3600 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Unit width 400 mm, small footprint.Cooling capacity 817 (W/f) for chamber volume 4,8 m³ / 4800 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Unit width 400 mm, small footprint.Cooling capacity 953 (W/f) for chamber volume 6,1 m³ / 6100 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Cooling capacity 1577 (W/f) for chamber volume 16,3 m³ / 16300 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 1914 (W/f) for chamber volume 19,4 m³ / 19400 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 2343 (W/f) for chamber volume 29,2 m³ / 29200 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 2547 (W/f) for chamber volume 34,2 m³ / 34200 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity rendered 1960 (W/f) for chamber volume 16,4 m³ / 16400 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice formation. Refrigerant gas...
%
Cooling capacity rendered 3389 (W/f) for chamber volume 37,6 m³ / 37600 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice formation. Refrigerant gas...
%
Unit width 400 mm, small footprint.Cooling capacity rendered 975 (W/f) for chamber volume 6 m³ / 6000 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice...
%
Unit width 400 mm, small footprint.Cooling capacity rendered 1302 (W/f) for chamber volume 10,6 m³ / 10600 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent...
%
Capacity 17 levels GN 2/1 (or 34x GN 1/1).Standard 5 pair of slides and 5 plasticized grids GN 2/1. Stainless steel austenitic structure (food).Opening door at 120 °, with a vertical lock with a key code.Hinges with stop at 100 °, closing with automatic recall.Built-in compressor unit (ambient T ° 32 ° C).Refrigerant gas R290.digital display.Ventilated internal evaporator.Integrated control panel, digital display.Electronic controller with automatic defrost.Possibility of use GN 2/1 or GN...
%
Capacity 40 levels GN 2/1 (or 80x GN 1/1).Standard 10 pair of slides and 10 plasticized grids GN 2/1. Stainless steel austenitic structure (food).Opening door at 120 °, with a vertical lock with a key code.Hinges with stop at 100 °, closing with automatic recall.Built-in compressor unit (ambient T ° 32 ° C)Refrigerant gas R290Ventilated internal evaporator.Integrated control panel, digital display.Electronic controller with automatic defrost.Possibility of use GN 2/1 or GN 1/1, spaced 60...
%
Extra large doors GN 2/1, on each side.Standard equipment: 3 grids GN 2/1 (650x530mm).3 ventilated evaporators.6 adjustable feet in stainless steel.Monocoque designManufactured in stainless steel (food), inside AISI 304, outside AISI 441.Independent upper top (dismountable), stainless steel AISI 304.Stainless steel rack and slides (anti-tilting), allowing to place the grids as one pleases.Stamped interior bottom, rounded angles and corners (without roughness).Doors with ergonomic handle (no...
%
2 independent plates (2x 5 kW).Cupboard (GN1/1) (340x940xh360mm). Made in stainless steel AISI 304, adjustable feet in stainless steel.Top waterproof (20/10 mm) in stainless steel AISI 304.Chimney in stainless steel AISI 304.Cooking surface, watertight "IPX4".Vitroceramics induction plate, (6 mm), with 4 independent inductors underneath.Energy regulator 6 positions (each cook zone), with control lamp, frontal accessibility allowing a very easy maintenance.Principe of INDUCTION: Heat is...
%
4 independent plates (4x 5 kW).Cupboard (GN2/1) (660x940xh360 mm). Made in stainless steel AISI 304, adjustable feet in stainless steel.Top waterproof (20/10 mm) in stainless steel AISI 304.Chimney in stainless steel AISI 304.Cooking surface, watertight "IPX4".Vitroceramics induction plate, (6 mm), with 4 independent inductors underneath.Energy regulator 6 positions (each cook zone), with control lamp, frontal accessibility allowing a very easy maintenance.Principe of INDUCTION: Heat is...