Reinforced structure in tubular steel painted in aluminum color, withtransparent protective coating.Wooden base with anti-slip rubber protection.Wheels Ø 200 mm, two fixed and two swiveling.
%
Tubular chromium-plated steel structure.Chromium-plated wire basket.Two fixed wheels, Ø 200 mm, two swiveling wheels, Ø 125 mm.When it is not in use, trolleys can be fitted together to save space.
%
Tubular steel structure, Ø 40 mm, with chromium-platedfinishing and transparent protective coating.Carpeted color base "black".Edges protected by black rubber bumper strips.Wheels (Ø 160 mm), with two fixed and two swiveling with brakes.
%
Structuur in stalen buizen, Ø 40 mm, vergulde afwerking met een transparante laag.Tapijt in "zwarte" basis kleur.Randen die door zwarte rubberstroken worden beschermd.Wielen (Ø 160 mm), met 2 vaste en 2 draaiende met rem.
%
General characteristics:AISI 304 stainless steel finish, between 12/10 mm and 30/10 mm thick, double cavity for better thermal and acoustic insulation (-60dB), adjustable stainless steel feet.Linear or angular implantations with left and right entries.Traction system with parallel stainless steel bars.Automatic advance system with 3 speeds.Ability to perform a continuous, basket-by-basket or delayedwash."Reversible" traction system, right left entry.Counter balanced wide opening doors with...
%
%
%
%
Unit width 400 mm, small footprint.Cooling capacity 671 (W/f) for chamber volume 3,6 m³ / 3600 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Unit width 400 mm, small footprint.Cooling capacity 817 (W/f) for chamber volume 4,8 m³ / 4800 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Unit width 400 mm, small footprint.Cooling capacity 953 (W/f) for chamber volume 6,1 m³ / 6100 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Cooling capacity 1577 (W/f) for chamber volume 16,3 m³ / 16300 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 1914 (W/f) for chamber volume 19,4 m³ / 19400 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 2343 (W/f) for chamber volume 29,2 m³ / 29200 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 2547 (W/f) for chamber volume 34,2 m³ / 34200 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity rendered 1960 (W/f) for chamber volume 16,4 m³ / 16400 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice formation. Refrigerant gas...
%
Cooling capacity rendered 3389 (W/f) for chamber volume 37,6 m³ / 37600 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice formation. Refrigerant gas...
%
Unit width 400 mm, small footprint.Cooling capacity rendered 975 (W/f) for chamber volume 6 m³ / 6000 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice...
%
Unit width 400 mm, small footprint.Cooling capacity rendered 1302 (W/f) for chamber volume 10,6 m³ / 10600 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent...
%
Capacity 10 levels GN 2/1 (or 20x GN 1/1).Upper part with stainless steel gallery on 3 sides. Construction in austenitic stainless steel (food).Walls and door made of double injected prey (high density CFC-free polyurethane).Door opening at 120°, with vertical latch and key lock, with a seal in the door frame, easily replaceable without tools.Hinges with stop at 100°, closing with automatic return, avoiding heat loss.Possibility of using GN 2/1 or GN 1/1 spacing 60 mm.Heating by resistances...
%
Capacity 20 GN 2/1 levels (or 40x GN 1/1). Construction in austenitic stainless steel (food).Walls and door made of double injected prey (high density CFC-free polyurethane).Door opening at 120°, with vertical latch and key lock, with a seal in the door frame, easily replaceable without tools.Hinges with stop at 100°, closing with automatic return, avoiding heat loss.Possibility of using GN 2/1 or GN 1/1 spacing 60 mm.Heating by resistances and pulsed air, homogeneity of the temperature...
%
Capacity 40 GN 2/1 levels (or 80x GN 1/1).SPECIAL BANQUETING: Standard 20 grids to optimize space inside the trollley.Up to eight (8) plates with a diameter of 300 mm can be stored per level, for a total of 160 plates. Construction in austenitic stainless steel (food).Walls and door made of double injected prey (high density CFC-free polyurethane).Door opening at 120°, with vertical latch and key lock, with a seal in the door frame, easily replaceable without tools.Hinges with stop at 100°,...