%
Variable speed (Min. 53 rpm & Max. 517 rpm), with Inverter.Timer from 0 to 30 minutes or continuousStandard accessories: whisk, spatula, hook and 10 L stainless steel tank.Table versions.Frame in painted steel (epoxy), upper cover in ABS, 4 lower cylinders for levelling.Fixed tank, automatic locking in working position.Protective plexiglass with safety device by microswitch.All parts in contact with the tank are made of stainless steel.Easy insertion and removal of utensils.When the...
%
3 speeds (1st Speed 77 rpm and 2nd Speed 154 rpm and 3rd Speed 308 rpm).Timer from 0 to 30 minutes or continuousStandard accessories: whisk, spatula, hook and 40 L stainless steel tank.High" versions on base.Very robust frame in painted steel (epoxy), upper cover in ABS, 4 lower cylinders for levellingRaising and lowering the tank with lever.Automatic locking of the tank in working position.Protection grid (and screws) in stainless steel, with safety device by microswitch.All parts in contact...
%
Variable speed (Min. 65 rpm & Max. 551 rpm), with Inverter.Timer from 0 to 30 minutes or continuousStandard accessories: whisk, spatula, hook and 40 L stainless steel tank.High" versions on base.Very robust frame in painted steel (epoxy), upper cover in ABS, 4 lower cylinders for levellingRaising and lowering the tank with lever.Automatic locking of the tank in working position.Protection grid (and screws) in stainless steel, with safety device by microswitch.All parts in contact with the...
%
%
Unit width 400 mm, small footprint.Cooling capacity 671 (W/f) for chamber volume 3,6 m³ / 3600 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Unit width 400 mm, small footprint.Cooling capacity 817 (W/f) for chamber volume 4,8 m³ / 4800 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Unit width 400 mm, small footprint.Cooling capacity 953 (W/f) for chamber volume 6,1 m³ / 6100 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Cooling capacity 1577 (W/f) for chamber volume 16,3 m³ / 16300 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 1914 (W/f) for chamber volume 19,4 m³ / 19400 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 2343 (W/f) for chamber volume 29,2 m³ / 29200 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 2547 (W/f) for chamber volume 34,2 m³ / 34200 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity rendered 1960 (W/f) for chamber volume 16,4 m³ / 16400 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice formation. Refrigerant gas...
%
Cooling capacity rendered 3389 (W/f) for chamber volume 37,6 m³ / 37600 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice formation. Refrigerant gas...
%
Unit width 400 mm, small footprint.Cooling capacity rendered 975 (W/f) for chamber volume 6 m³ / 6000 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice...
%
Unit width 400 mm, small footprint.Cooling capacity rendered 1302 (W/f) for chamber volume 10,6 m³ / 10600 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent...
%
Ventilated motor with thermal protection. Ventilated engine.Frame, upper and retrieval basin in stainless steel AISI 304.Chopper group removable, (Ø 98 mm) (easy maintenance), possibility to inverse rotation (if blocked). Grid of 6mm and knife in stainless steel "self sharpening".Drive gears in oil bath, made for intensive use.Control (24 V), thermic protection.
%
The outer frame is made of "aluminum alloy".The body of the chopper as well as the internal auger are also made of "aluminium alloy" treated for food and stainless steel, all the internal parts are easily dismantled for an easy maintenance.Upper bowl in stainless steel AISI 304.Supplied as standard with 6 mm grid.Self-sharpening stainless steel grid and knife.Gear drive in oil bath.Low voltage control 24 V.Supplied with a stainless steel AISI 304 container to collect the minced meat.The...
%
Ventilated motor with thermal protection. Exterior chassis in "aluminum alloy".The body of the chopper and the inside out leadscrew are also manufactured in treated "aluminum alloy" for food and stainless steel, all the interior parts are easily dismantled allowing easy maintenance.Upper bowl in stainless steel AISI 304.Standard delivered with a 6 mm grid.Grid and blade in stainless steel "auto-sharping".Ventilated motor, ideally designed for intensive use.Wheel drive in oil bath.Low voltage...
%
Exterior chassis in "aluminum alloy".The body of the chopper and the inside out leadscrew are also manufactured in treated "aluminum alloy" for food and stainless steel, all the interior parts are easily dismantled allowing easy maintenance.Upper bowl in stainless steel AISI 304.Standard delivered with a 6 mm grid.Grid and blade in stainless steel "auto-sharping".Wheel drive in oil bath.Low voltage control 24V.Aplliances are in compliance with standards (CE) in force.