- Air condenser.- Versatile pasto turbine cookers for cooking, tempering, pasteurizing and freezing all mixtures or pastes. - Multilingual display with 14 pre-programmed cycles and 10 programmable production cycles. - Different heat treatments are carried out in a single cylinder, avoiding any handling or transfer. - Possibility of slow, fast or intermittent agitation. - Automatic memory of the last cycle. - Mix per cycle: 15/30 litres. - Cycle time: 90/130 mi
%
%
- Water condenser.- Versatile pasto turbine cookers for cooking, tempering, pasteurizing and freezing all mixtures or pastes. - Multilingual display with 14 pre-programmed cycles and 10 programmable production cycles. - Different heat treatments are carried out in a single cylinder, avoiding any handling or transfer. - Possibility of slow, fast or intermittent agitation. - Automatic memory of the last cycle. - Mix per cycle: 15/30 litres. - Cycle time: 90/130 min.
%
%
- Air condenser.- Automatic pasteurizer for high and low pasteurization. - Transparent cover. - Faucet has an integrated cleaning system. - Intelligent memory that allows to repeat, if necessary, the pasteurization cycle. - Mix per cycle: 15/30 litres. - Cycle time: 80/120min.
%
- Air condenser.- Automatic pasteurizer for high and low pasteurization. - Transparent cover. - Faucet has an integrated cleaning system. - Intelligent memory that allows to repeat, if necessary, the pasteurization cycle. - Mix per cycle: 15/30 litres. - Cycle time: 80/120min.
%
- Water condenser.- Automatic pasteurizer for high and low pasteurization. - Transparent cover. - Faucet has an integrated cleaning system. - Intelligent memory that allows to repeat, if necessary, the pasteurization cycle. - Mix per cycle: 15/30 litres. - Cycle time: 80/120min.
%
- Water condenser.- Automatic pasteurizer for high and low pasteurization. - Transparent cover. - Faucet has an integrated cleaning system. - Intelligent memory that allows to repeat, if necessary, the pasteurization cycle. - Mix per cycle: 15/30 litres. - Cycle time: 80/120min.
%
Internal dimensions 800x1200xh100Pizza production / hour: from Ø 250 mm "230 gr." = 220 pizzas, up to Ø 500 mm "915 gr." = 35 pizzas (cooking time 3.5 to 5 minutes)Standard with stainless steel base on swivel wheels (with brakes)Possibility to stack up to 3 ovens of the same model Conctructed completely in stainless steel AISI 304, thermal isolation in ceramic fibre.Cooking tunnel: electronic regulation of the temperature and de velocity of heat transition. Quick reach of temperature, easy...
%
Internal dimensions 800x1200xh100Pizza production/hour: from Ø 250 mm "230 gr." = 220 pizzas, up to Ø 500 mm "915 gr." = 35 pizzas (cooking time 3.5 to 5 minutes)Standard with stainless steel base on swivel wheels (with brakes)Possibility to stack up to 3 ovens of the same model Conctructed completely in stainless steel AISI 304, thermal isolation in ceramic fibre.Cooking tunnel: electronic regulation of the temperature and de velocity of heat transition. Quick reach of temperature, easy...
%
Top 1.2 mm with rounding downwards 50 mm.top with on the right and on the left a side panel. Equipped with 2 sockets 230V/1. Manufactured in stainless steel AISI 304 on adjustable feet in PVC.
%
Top 1.2 mm with rounding downwards 50 mmTop with on the right and on the left a side panel.Equipped with 2 sockets 230V/1.Manufactured in stainless steel AISI 304 on adjustable feet in PVC.
%
Superior top 1,5 mm, rounded edges, with side panels on left and right.750 = 514x650 mm, 1125 = 889x650 mm, 1500 = 1264x650 mm.With 2 plugs 230V/1.Made in stainless steel AISI 304 with adjustable feet in stainless steel 150 mm.
%
Superior top 1,5 mm, rounded edges, with side panels on left and right.750 = 514x650 mm, 1125 = 889x650 mm, 1500 = 1264x650 mm.With 2 plugs 230V/1.Made in stainless steel AISI 304 with adjustable feet in stainless steel 150 mm.
%
Superior top 1,5 mm, rounded edges, with side panels on left and right.750 = 514x650 mm, 1125 = 889x650 mm, 1500 = 1264x650 mm.With 2 plugs 230V/1.Made in stainless steel AISI 304 with adjustable feet in stainless steel 150 mm.
%
Cooling capacity 586 (W/f) for chamber volume 2,8 m³ / 2800 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 895 (W/f) for chamber volume 5,7 m³ / 5700 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 1058 (W/f) for chamber volume 7,6 m³ / 7600 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 1733 (W/f) for chamber volume 17,3 m³ / 17300 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 2463 (W/f) for chamber volume 30,5 m³ / 30500 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity rendered 1881 (W/f) for chamber volume 15,7 m³ / 15700 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation,...
%
Cooling capacity rendered 2961 (W/f) for chamber volume 28,2 m³ / 28200 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation,...
%
Cooling capacity rendered 1072 (W/f) for chamber volume 7,1 m³ / 7100 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation, as...
%
Cooling capacity rendered 1288 (W/f) for chamber volume 9,5 m³ / 9500 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation, as...