Internal dimensions 800x1200xh100Pizza production / hour: from Ø 250 mm "230 gr." = 220 pizzas, up to Ø 500 mm "915 gr." = 35 pizzas (cooking time 3.5 to 5 minutes)Standard with stainless steel base on swivel wheels (with brakes)Possibility to stack up to 3 ovens of the same model Conctructed completely in stainless steel AISI 304, thermal isolation in ceramic fibre.Cooking tunnel: electronic regulation of the temperature and de velocity of heat transition. Quick reach of temperature, easy...
%
Internal dimensions 800x1200xh100Pizza production/hour: from Ø 250 mm "230 gr." = 220 pizzas, up to Ø 500 mm "915 gr." = 35 pizzas (cooking time 3.5 to 5 minutes)Standard with stainless steel base on swivel wheels (with brakes)Possibility to stack up to 3 ovens of the same model Conctructed completely in stainless steel AISI 304, thermal isolation in ceramic fibre.Cooking tunnel: electronic regulation of the temperature and de velocity of heat transition. Quick reach of temperature, easy...
%
Chamber for 1 pizza Ø 430 mm.Fresh pizza: cooking in 3'30, frozen in 4'30.Realization in stainless steel.Insulation in rock wool very thick.Unique concept: heating by infra-red quartz (1050°C)Sole in refractory stone.Very fast pre-heating (15 min.).Timer 15 min. with continuous position.Thermostat 0-350°C for the cooking chamber, 1 energy regulator for the sole, tensioning warning light, heating warning light.Safety thermostat delivered standard.Door with double insulation fitted with a...
%
In-line wok burner Ø 290 mm (21.44 kW).Deep-drawn and waterproof cooking surface used to channel water for the cooling of the top.Lateral water drainage, equipped with an overflow drain.1 control valve per burner, connection (gas 1/2").Recuperation drawers.Made of AISI 441 stainless steel, Top of AISI 304 stainless steel (20/10th).
%
In-line wok type burners Ø 290 mm (21.44 kW).Deep-drawn and waterproof cooking surface used to channel water for cooling the top.Lateral water drainage, equipped with an overflow drain.1 control valve per burner, connection (gas 3/4").Recuperation drawers.Made of AISI 441 stainless steel, Top of AISI 304 stainless steel (20/10th).
%
Burners type wok 2x Ø 290 mm 21,44 kW and 1x Ø 230 mm 10,13 kW.Embedded cooking top, catching basin underneath.Lateral drain, pouring basin with removable filter, foreseen of a cover and a drain hole.1 control vane per burner, gas connection (3/4").Water curtain for the cooling of the top, inclusive a tap and a ranging rack.Made of AISI 441 stainless steel, Top of AISI 304 stainless steel (20/10th).
%
In-line wok type burners Ø 290 mm 21,44 kW.Deep-drawn and waterproof cooking surface used to channel water for cooling the top.Lateral water drainage, equipped with an overflow drain.1 control valve per burner, connection (gas 3/4").Recuperation drawers.Made of AISI 441 stainless steel, Top of AISI 304 stainless steel (20/10th).
%
Burners type wok 3x Ø 290 mm 21,44 kW and 2x Ø 230 mm 10,13 kW.Embedded cooking top, catching basin underneath.Lateral drain, pouring basin with removable filter, foreseen of a cover and a drain hole.1 control vane per burner, gas connection (4/4").Water curtain for the cooling of the top, inclusive a tap and a ranging rack.Made of AISI 441 stainless steel, Top of AISI 304 stainless steel (20/10th).
%
Burners type wok 4x Ø 290 mm 21,44 kW und 3x Ø 230 mm 10,13 kW.Embedded cooking top, catching basin underneath.Lateral drain, pouring basin with removable filter, foreseen of a cover and a drain hole.1 control vane per burner, gas connection (4/4").Water curtain for the cooling of the top, inclusive a tap and a ranging rack.Made of AISI 441 stainless steel, Top of AISI 304 stainless steel (20/10th).
%
Cooling capacity rendered 633 (W/f) for chamber volume 3,0 m³ / 3000 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are...
%
Cooling capacity rendered 824 (W/f) for chamber volume 5,0 m³ / 5000 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are...
%
Cooling capacity rendered 1258 (W/f) for chamber volume 10,2 m³ / 10200 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity rendered 1509 (W/f) for chamber volume 13,2 m³ / 13200 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity rendered 2313 (W/f) for chamber volume 27,8 m³ /27800 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity 2139 (W/f) for room volume 18,1 m³ / 18100 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard...
%
Cooling capacity 3490 (W/f) for room volume 34,3 m³ / 34300 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by thermostatic valve.Also equipped with a high pressure switch (fixed calibration) (C-PMAX-R). Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a...
%
Cooling capacity 981 (W/f) for room volume 6,2 m³ / 6200 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard with a high...
%
Cooling capacity 1800 (W/f) for room volume 14,9 m³ / 14900 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard with a...
%
Tank dimensions 250x320xh280 mm with cold zone and lower drain tap.Oil quantity for use, min. 12 liters, max. 14 liters per tank.Tank filters made of chrome-plated steel.Supplied with 1 basket 235x275xh105 mm per tank, made of chrome-plated steel with athermal handle.Stainless steel lids.Hourly production 2x 20 kg.Heating by shielded resistors in the tank.Regulation from 100°C to 190°C by thermostat with indicator light.Standard safety thermostat.Lower cabinet with oil filtering bins.Made of...
%
Tank welded with cold wall and drainage tap, oil capacity min. 12 liters max. 14 liters.Tank filter in chrome stainless steelRemovable heating elementTemperature range 100°C to 190°CIncluded 1 basket 235x275xh105 mmBase complete with drip trayAdjustable stainless steel feet.
%
- Tank welded with cold wall and drainage tap, oil capacity min. 13 liters max. 15 liters per tank.- Tank filter in chrome stainless steel.- Heated by cast iron burners.- Temperature range 90°C to 190°C.- Included 1 basket 235x290xh110 mm.- Base complete with drip tray.
%
Tank welded with cold wall and drainage tap, oil capacity min. 13 liters max. 15 liters.Tank filter in chrome stainless steel.Heated by cast iron burners.Temperature range 90°C to 190°C.Included 1 basket 235x290xh110 mm.Base complete with drip tray.
%
Tank in stainless steel (349x580x400mm), with cold zone.2 x ½ baskets including (165x335x150mm).4 burners " high efficiency" (21kW).Regulation by thermostatic valve from 100° to 200°C. Safety thermostat.Pilot and safety thermocouple. Manual ignition.Discharge by safety valve. 1 tray.Adjustable feet "synthetic".Manufactured in stainless steel.
%
Basket 205x305xh145 mm. (Isolated) vat in stainless steel with draining board.Removable resistance bloc, easy maintenance.Adjustable elements to adapt the power according to the type of cooking. (4-8-12 kW).Oil filtered by decantation, permits to cook fish, fries, doughnuts... with little oil consumption and without changing flavor or burned food rests.Emptying through a high flow crane inside the cupboard, collecting tray with filter.Baskets, athermal grips.Remote bulb thermostat in...