%
High version, easier loading / unloading of baskets,..."Double-walled" Standard versionWith anti-pollution device, AB type (Break Tank), including rinse pump (atmospheric boiler)Load height 405 mmPlate height 380 mm3 stages: washing, discharge, rinseDrain pump, standardRinse pump, standard (atmospheric boiler) Double-walled version completely in stainless steel AISI 304. - From 60 till 24 baskets/hour, cycles 60'' - 120'' - 150" or continuous - Rotating wash and rinse arms (upper and lower),...
%
Low version, installation option under sinks and cupboards etc...."Double-walled" VersionWith anti-pollution device, AB type (Break Tank), including rinse pump (atmospheric boiler)Load height 405 mmPlate height 380 mm3 stages: washing, discharge, rinseDrain pump, standardRinse pump, standard (atmospheric boiler) Double-walled version completely in stainless steel AISI 304. - From 60 till 24 baskets/hour, cycles 60'' - 120'' - 150" or continuous - Rotating wash and rinse arms (upper and...
%
Ø tot 450 mm.Platen in R.V.S. zijn verwarmd door weerstanden, met als waarborg een grotere homogeniteit van de warmte, de thermostaat sonde is van de type thermokoppel welke een groter gevoeligheid heeft.Afgeronde plaat , die een uniforme omlijsting biedt.Grote ruimte tussen de platen, duidelijke zigbaarheid welke een groteproductiviteit waarborgt.R.V.S. protectierooster rond de platen.Gemakkelijk gebruik dankzij hefboomsysteem onder de onderstel plaat met als doel de dikte te...
%
- Ø till 450 mm.- Manufactured entirely in stainless steel.- Electronic thermostats.- New sort of resistances, guaranteeing a bigger homogenity in heat, thermostat probe is of the "thermoset" type, much more sensitive.- Rounded plate, forming an uniform peripheral border.- Big space between the plates, clear view, makng the production process easier for a bigger productivity.- Protection grid in stainless steel bordering the plates, with emergency switch.- Easy to use thanks to the lever...
%
Water softener continuously, incorporated (ATTENTION: cold water connection) Height of load Ø 465 mm.Realisation "double walled". with thermic insulation.From 60 to 24 baskets/hour, PLD cycles 60", 120", 150" or continuous.3 phases: wash, unload, rinse.Water consumption per cycle 3 liters.Vertical wash pump (double flux), auto-drain and auto-wash (1,5 Kw).Standard discharge pump.Standard rinse pump (atmospheric boiler) Control panel at the top of the hood, digital display.Basket 600x500 mm,...
%
Integration of the "Green System H.R.S." Condenser vapor-recovery unit, big energy savings (ATTENTION: connection to cold water)Watersofterner continuously, incorporated. (ATTENTION: connection to cold water)Height of load Ø 465 mmRealisation "double walled". with thermic insulation.From 60 to 24 baskets/hour, PLD cycles 60", 120", 150" or continuous.3 phases: wash, unload, rinse.Water consumption per cycle 3 liters.Standard discharge pump.Standard rinse pump (atmospheric boiler) Control...
%
2 independent plates (2x 3 kW).Cupboard (GN 1/1) (340x940xh360 mm). Made in stainless steel AISI 304, adjustable feet in stainless steel.Stamped and waterproof top (20/10 mm) in stainless steel AISI 304.Chimney in stainless steel AISI 304.Square cast iron plates, 300x300 mm, with a waterproof edge in stainless steel, safety device in case of overheating. Regulation of the heating power by means of a 7-position switch, frontal accessibility allowing a very easy maintenance.
%
4 independent square plates (3x 3 kW, 1x 4 kW).Cupboard (GN 2/1) (660x940xh360 mm). Made in stainless steel AISI 304, adjustable feet in stainless steel.Stamped and waterproof top (20/10 mm) in stainless steel AISI 304.Chimney in stainless steel AISI 304.Square cast iron plates, 300x300 mm, with a waterproof edge in stainless steel, safety device in case of overheating. Regulation of the heating power by means of a 7-position switch, frontal accessibility allowing a very easy maintenance.
%
4 independent square plates (3x 3 kW, 1x 4 kW).Oven (10 kW) GN 2/1 (540x940xh300 mm) Made in stainless steel AISI 304, adjustable feet in stainless steel.Stamped and waterproof top (20/10 mm) in stainless steel AISI 304.Chimney in stainless steel AISI 304.Square plates in cast iron, 300x300 mm, with a waterproof stainless steel edge, safety device in case of overheating. Regulation of the heating power with a 7-position switch, frontal accessibility allowing a very easy maintenance.
%
4 plates Ø 230 mm, independent (4x 2.6 kW).Oven GN 2/1, dimensions 540x650xh300 mm (6 kW). Made of 18/10 AISI 304 stainless steel, deep-drawn "top" thickness 15/10 mm, adjustable stainless steel feet (150/200 mm), waterproof "IPX4".AISI 430 stainless steel oven, rounded corners, steel bottom, removable plate structure, double-walled deep-drawn door with thermal insulation (40 mm), counterbalanced spring hinges, stainless steel handle.Cast iron plates, with a stainless steel sealing edge....
%
4 plates Ø 230 mm, independent (4x 2.6 kW).Oven GN 2/1, dimensions 540x650xh300 mm (6 kW). Made of 18/10 AISI 304 stainless steel, deep-drawn "top" thickness 15/10 mm, adjustable stainless steel feet (150/200 mm), waterproof "IPX4".AISI 430 stainless steel oven, rounded corners, steel bottom, removable plate structure, double-walled deep-drawn door with thermal insulation (40 mm), counterbalanced spring hinges, stainless steel handle.Cast iron plates, with a stainless steel sealing edge....
%
%
- 4 plates 230x230 mm, independent (4x 2.6 kW).- Oven GN 2/1, dimensions 540x650xh300 mm (6 kW).- Made of 18/10 AISI 304 stainless steel, deep-drawn "top" thickness 15/10 mm, adjustable stainless steel feet (150/200 mm), waterproof "IPX4". - AISI 430 stainless steel oven, rounded corners, steel bottom, removable plate structure, double-walled deep-drawn door with thermal insulation (40 mm), counterbalanced spring hinges, stainless steel handle. - Cast iron plates, with a stainless steel...
%
- 4 separate cooking fields Ø 230 mm (4x 2.2 kW).- Oven GN 2/1, dimensions 540x650xh300 mm (6 kW).- Made of AISI 304 stainless steel, deep-drawn "top" (15/10 mm), adjustable stainless steel feet (150/200 mm).- Ceramic glass (6 mm), with radiant heaters diameter 300 mm. Glass ceramic plates are characterized by a fast temperature setting. Graduated energy regulator for each cooking field. - Electric oven, heating by stainless steel resistors placed in the vault and under the bottom of the...
%
4 independent plates (4x 4 kW).GN 2/1 oven, dimensions 575x700xh300 mm (6 kW). Made of AISI 304 stainless steel, deep-drawn "Top" (20/10th) with waterproof liquid collection basin, adjustable stainless steel feet (150/200mm), waterproof "IPX5".AISI 430 stainless steel oven, rounded corners, cast iron floor, removable structure, double-walled door, counterbalanced spring hinges, stainless steel handle.Cast iron square plates, 300x300 mm, stainless steel sealing edge. Regulation by 7-position...
%
4 independent plates (4x 4 kW).GN 2/1 oven, dimensions 575x700xh300 mm (6 kW). Made of AISI 304 stainless steel, deep-drawn "Top" (20/10th) with waterproof liquid collection basin, adjustable stainless steel feet (150/200mm), waterproof "IPX5".AISI 430 stainless steel oven, rounded corners, cast iron floor, removable structure, double-walled door, counterbalanced spring hinges, stainless steel handle.Cast iron square plates, 300x300 mm, stainless steel sealing edge. Regulation by 7-position...
%
Cooling capacity rendered 633 (W/f) for chamber volume 3,0 m³ / 3000 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are...
%
Cooling capacity rendered 824 (W/f) for chamber volume 5,0 m³ / 5000 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are...
%
Cooling capacity rendered 1258 (W/f) for chamber volume 10,2 m³ / 10200 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity rendered 1509 (W/f) for chamber volume 13,2 m³ / 13200 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity rendered 2313 (W/f) for chamber volume 27,8 m³ /27800 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity 2139 (W/f) for room volume 18,1 m³ / 18100 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard...
%
Cooling capacity 3490 (W/f) for room volume 34,3 m³ / 34300 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by thermostatic valve.Also equipped with a high pressure switch (fixed calibration) (C-PMAX-R). Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a...
%
Cooling capacity 981 (W/f) for room volume 6,2 m³ / 6200 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard with a high...