Cooling capacity rendered 1960 (W/f) for chamber volume 16,4 m³ / 16400 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice formation. Refrigerant gas...
%
Cooling capacity rendered 3389 (W/f) for chamber volume 37,6 m³ / 37600 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice formation. Refrigerant gas...
%
Unit width 400 mm, small footprint.Cooling capacity rendered 975 (W/f) for chamber volume 6 m³ / 6000 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice...
%
Unit width 400 mm, small footprint.Cooling capacity rendered 1302 (W/f) for chamber volume 10,6 m³ / 10600 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent...
%
Capacity 17 levels GN 2/1 (or 34x GN 1/1).Standard 5 pair of slides and 5 plasticized grids GN 2/1. Stainless steel austenitic structure (food).Opening door at 120 °, with a vertical lock with a key code.Hinges with stop at 100 °, closing with automatic recall.Built-in compressor unit (ambient T ° 32 ° C).Refrigerant gas R290.digital display.Ventilated internal evaporator.Integrated control panel, digital display.Electronic controller with automatic defrost.Possibility of use GN 2/1 or GN...
%
Capacity 40 levels GN 2/1 (or 80x GN 1/1).Standard 10 pair of slides and 10 plasticized grids GN 2/1. Stainless steel austenitic structure (food).Opening door at 120 °, with a vertical lock with a key code.Hinges with stop at 100 °, closing with automatic recall.Built-in compressor unit (ambient T ° 32 ° C)Refrigerant gas R290Ventilated internal evaporator.Integrated control panel, digital display.Electronic controller with automatic defrost.Possibility of use GN 2/1 or GN 1/1, spaced 60...
%
Capacity 3x GN 1/1.Recessed dimensions 1090x585. 160 mm-deep stamped tank (GN-150 mm trays), rounded angles and - Deep-drawn tank 160mm deep (GN-150mm tanks), rounded corners and corners (perfect hygiene)1/2" drain.Cooling by a coil evaporator (copper), placed just below the tankControl panel with electronic regulation of +2° +8°, digital displayCFC-free expanded polyurethane insulationPredisposed for the placement of an additional thermometer to display the T° on the customer side (On...
%
Capacity 4x GN 1/1.Recessed dimensions 1415x585. Deep-drawn tank 160mm deep (GN-150mm trays), rounded corners and corners (perfect hygiene)1/2" drain.Cooling by a coil evaporator (copper), placed just below the tankControl panel with electronic regulation of +2° +8°, digital displayCFC-free expanded polyurethane insulationPredisposed for the placement of an additional thermometer to display the T° on the customer side (On request)Integrated refrigeration unit, refrigerant R290aAutomatic...
%
Capacity 5x GN 1/1.Recessed dimensions 1740x585. Deep-drawn tank 160mm deep (GN-150mm trays), rounded corners and corners (perfect hygiene)1/2" drain.Cooling by a coil evaporator (copper), placed just below the tankControl panel with electronic regulation of +2° +8°, digital displayCFC-free expanded polyurethane insulationPredisposed for the placement of an additional thermometer to display the T° on the customer side (On request)Integrated refrigeration unit, refrigerant R290aAutomatic...
%
Standard equipment: 6 trays GN 1/3 high 40 mm. Stainless steel construction (Austenitic - Food) and anodized aluminum finishing.Sliding back doors in glass, front window in "toughened glass", curved.Copper evaporator "serpentine" below the tank, refrigerant R600a, drain for the condensate.Regulation by electronic thermostat (digital), Lighting by "LED". NB Provide discharge (or) a condensate drain pan.
%
Standard equipment: 8 trays GN 1/3 high 40 mm. Stainless steel construction (Austenitic - Food) and anodized aluminum finishing.Sliding back doors in glass, front window in "toughened glass", curved.Copper evaporator "serpentine" below the tank, refrigerant R134A, drain for the condensate.Regulation by electronic thermostat (digital).Lighting by "LED".Built-in group (Energy Class 4), quiet, ventilated condenser.Adjustable feet.NB Provide discharge (or) a condensate drain pan.
%
Système de refroidissement par groupe monobloc, classe climatique 4 (température 30°C et humidité 55%). Évaporateur ventilé.Gaz réfrigérant R455a.Régulation électronique, température +2°C +8°C.Dégivrage automatique.
%
Cooling capacity 2139 (W/f) for room volume 18,1 m³ / 18100 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard...
%
Cooling capacity 3490 (W/f) for room volume 34,3 m³ / 34300 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by thermostatic valve.Also equipped with a high pressure switch (fixed calibration) (C-PMAX-R). Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a...
%
Cooling capacity 981 (W/f) for room volume 6,2 m³ / 6200 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard with a high...
%
Cooling capacity 1800 (W/f) for room volume 14,9 m³ / 14900 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard with a...
%
%
Cooling capacity rendered 1881 (W/f) for chamber volume 15,7 m³ / 15700 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation,...
%
Cooling capacity rendered 2961 (W/f) for chamber volume 28,2 m³ / 28200 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation,...
%
Cooling capacity rendered 1072 (W/f) for chamber volume 7,1 m³ / 7100 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation, as...