Tank 306x510xh110 mm, superficie 15,8 dm2 Deep-drawn top thickness 15/10thStainless steel tank AISI 316 "COMPOUND", with high thermal conductivity (Food certified according to European regulation CE n.1935/2004)Plug and extension for discharge, supplied as standardElectrical heating: Stainless steel armoured resistors, positioned under the tank, regulation from 120°C to 300°.Safety device in case of overheatingWater protection degree IPX5Made of AISI 304 stainless steel, adjustable stainless...
%
Tank 306x510xh110 mm, superficie 15,8 dm2 Deep-drawn top thickness 15/10thStainless steel tank AISI 316 "COMPOUND", with high thermal conductivity (Food certified according to European regulation CE n.1935/2004)Plug and extension for discharge, supplied as standardElectrical heating: Stainless steel armoured resistors, positioned under the tank, regulation from 120°C to 300°.Safety device in case of overheatingWater protection degree IPX5Made of AISI 304 stainless steel, adjustable stainless...
%
Tank dimensions 630x510xh110 mm, surface 32,1 dm2. Deep-drawn top thickness 15/10thStainless steel tank AISI 316 "COMPOUND", with high thermal conductivity (Food certified according to European regulation CE n.1935/2004)Plug and extension for discharge, supplied as standardElectrical heating: Stainless steel armoured resistors, positioned under the tank, regulation from 120°C to 300°.Safety device in case of overheatingWater protection degree IPX5Made of AISI 304 stainless steel, adjustable...
%
Tank dimensions 630x510xh110 mm, surface 32,1 dm2. Deep-drawn top thickness 15/10thStainless steel tank AISI 316 "COMPOUND", with high thermal conductivity (Food certified according to European regulation CE n.1935/2004)Plug and extension for discharge, supplied as standardElectrical heating: Stainless steel armoured resistors, positioned under the tank, regulation from 120°C to 300°.Safety device in case of overheatingWater protection degree IPX5Made of AISI 304 stainless steel, adjustable...
%
Cooling capacity rendered 633 (W/f) for chamber volume 3,0 m³ / 3000 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are...
%
Cooling capacity rendered 824 (W/f) for chamber volume 5,0 m³ / 5000 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are...
%
Cooling capacity rendered 1258 (W/f) for chamber volume 10,2 m³ / 10200 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity rendered 1509 (W/f) for chamber volume 13,2 m³ / 13200 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity rendered 2313 (W/f) for chamber volume 27,8 m³ /27800 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity 2139 (W/f) for room volume 18,1 m³ / 18100 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard...
%
Cooling capacity 3490 (W/f) for room volume 34,3 m³ / 34300 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by thermostatic valve.Also equipped with a high pressure switch (fixed calibration) (C-PMAX-R). Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a...
%
Cooling capacity 981 (W/f) for room volume 6,2 m³ / 6200 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard with a high...
%
Cooling capacity 1800 (W/f) for room volume 14,9 m³ / 14900 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard with a...
%
Tank dimensions 630x510xh110 mm, surface area 32.1 dm2. Made of AISI 304 stainless steel, deep-drawn "top" (20/10 mm), adjustable stainless steel feet (150-200 mm), waterproof IPX5Tank in AISI 316 "COMPOUND" stainless steel (Food certified according to European regulation CE n.1935/2004), with high thermal conductivity.Plug and extension for discharge, supplied as standard.Electric heating: stainless steel armoured resistors, positioned under the tank, regulation from 120 to 300°C.Safety...
%
Tank dimensions 630x510xh110 mm, surface area 32.1 dm2. Made of AISI 304 stainless steel, deep-drawn "top" (20/10 mm), adjustable stainless steel feet (150-200 mm), waterproof IPX5Tank in AISI 316 "COMPOUND" stainless steel (Food certified according to European regulation CE n.1935/2004), with high thermal conductivity.Plug and extension for discharge, supplied as standard.Electric heating: stainless steel armoured resistors, positioned under the tank, regulation from 120 to 300°C.Safety...
%
4 drawers version GN 1/1 (maximum height 100 mm).1 ventilated evaporator "treaty".4 adjustable stainless steel feet. Monocoque designInside and outside (top included) manufactured in stainless steel AISI 441 (also the back).Stamped interior bottom, rounded angles and corners (without roughness).Drawers with ergonomic handle, on telescopic slides, "snap-fit" closure by magnetic joint (easy replacement without tools).Compressor unit climate class 4 (30°C Temperature & 55% Humidity), ),...
%
Tank dimensions 306x510xh110 mm, surface 15,8 dm2. Deep-drawn top thickness 15/10thStainless steel tank AISI 316 "COMPOUND", with high thermal conductivity (Food certified according to European regulation CE n.1935/2004)Plug and extension for discharge, supplied as standardGas heating: stainless steel burners with stabilized flame, regulation 100 to 250°C, piezoelectric ignitionSafety device in case of overheatingWater protection degree IPX5Made of AISI 304 stainless steel, adjustable...
%
Tank dimensions 630x510xh110 mm, surface 32,1 dm2. Deep-drawn top thickness 15/10thStainless steel tank AISI 316 "COMPOUND", with high thermal conductivity (Food certified according to European regulation CE n.1935/2004)Plug and extension for discharge, supplied as standardGas heating: stainless steel burners with stabilized flame, regulation 100 to 250°C, piezoelectric ignitionSafety device in case of overheatingWater protection degree IPX5Made of AISI 304 stainless steel, adjustable...
%
Tank dimensions 630x510xh110 mm, surface area 32.1 dm2. Made of AISI 304 stainless steel, deep-drawn "top" (20/10 mm), adjustable stainless steel feet (150-200 mm), waterproof IPX5Tank in AISI 316 "COMPOUND" stainless steel (Food certified according to European regulation CE n.1935/2004), with high thermal conductivity.Plug and extension for discharge, supplied as standard.Gas heating: stainless steel burners with stabilized flame, regulation 100 to 250°C, piezoelectric ignition.Safety device...