Unit width 400 mm, small footprint.Cooling capacity 671 (W/f) for chamber volume 3,6 m³ / 3600 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Unit width 400 mm, small footprint.Cooling capacity 817 (W/f) for chamber volume 4,8 m³ / 4800 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Unit width 400 mm, small footprint.Cooling capacity 953 (W/f) for chamber volume 6,1 m³ / 6100 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Cooling capacity 1577 (W/f) for chamber volume 16,3 m³ / 16300 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 1914 (W/f) for chamber volume 19,4 m³ / 19400 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 2343 (W/f) for chamber volume 29,2 m³ / 29200 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 2547 (W/f) for chamber volume 34,2 m³ / 34200 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity rendered 1960 (W/f) for chamber volume 16,4 m³ / 16400 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice formation. Refrigerant gas...
%
Cooling capacity rendered 3389 (W/f) for chamber volume 37,6 m³ / 37600 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice formation. Refrigerant gas...
%
Unit width 400 mm, small footprint.Cooling capacity rendered 975 (W/f) for chamber volume 6 m³ / 6000 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice...
%
Unit width 400 mm, small footprint.Cooling capacity rendered 1302 (W/f) for chamber volume 10,6 m³ / 10600 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent...
%
Glass loading height 300 mm.From 60 to 24 baskets/hour, PLD cycles 60", 120", 150".3 phases: washing, unloading, rinsing.Drain pump as standardRinsing pump as standard (atmospheric boiler).Made of stainless steel AISI 304. Rotating washing and rinsing arms (upper and lower). Self-cleaning nozzles. Tank with rounded edges (8 lt - 0,6 kW). Stamped basket slides, no roughness and no limestone incrustation. Integral filter in "Composit" tank. Patented" pump filter to keep the washing water longer...
%
%
2 independent plates (2x 5 kW).Cupboard (GN1/1) (340x940xh360mm). Made in stainless steel AISI 304, adjustable feet in stainless steel.Top waterproof (20/10 mm) in stainless steel AISI 304.Chimney in stainless steel AISI 304.Cooking surface, watertight "IPX4".Vitroceramics induction plate, (6 mm), with 4 independent inductors underneath.Energy regulator 6 positions (each cook zone), with control lamp, frontal accessibility allowing a very easy maintenance.Principe of INDUCTION: Heat is...
%
4 independent plates (4x 5 kW).Cupboard (GN2/1) (660x940xh360 mm). Made in stainless steel AISI 304, adjustable feet in stainless steel.Top waterproof (20/10 mm) in stainless steel AISI 304.Chimney in stainless steel AISI 304.Cooking surface, watertight "IPX4".Vitroceramics induction plate, (6 mm), with 4 independent inductors underneath.Energy regulator 6 positions (each cook zone), with control lamp, frontal accessibility allowing a very easy maintenance.Principe of INDUCTION: Heat is...
%
6 mm vitro of "WOK Bowl" (Ø 310 mm), high temperature, stainless steel with chamfered and circular edges.Coil 280 mm, cooling fan.Function "Booster" concentration of power (3600 W) on the inductor.Regulation of 12 positions from 100 W to 3600 W.Black vitroceramic, high temperature, 100% waterproof."Built-In" casing in stainless steel AISI 304 (30/10th).Glass touch control panel (detects the presence of finger), manual power setting with On-Off button. 12 positions, 3 preset power buttons...
%
%
6 mm vitro of "WOK Bowl" (Ø 310 mm), high temperature, stainless steel with chamfered and circular edges.Coil 280 mm, cooling fan.Regulation of 12 positions from 100 W to 6000 W.Single-voltage 400/3N (not switchable).Black vitroceramic, high temperature, 100% waterproof."Built-In" casing in stainless steel AISI 304 (30/10th).Glass touch control panel (detects the presence of finger), manual power setting with On-Off button. 12 positions, 3 preset power buttons (6/10/12), timer 0-99 minutes,...