Unit width 400 mm, small footprint.Cooling capacity 671 (W/f) for chamber volume 3,6 m³ / 3600 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Unit width 400 mm, small footprint.Cooling capacity 817 (W/f) for chamber volume 4,8 m³ / 4800 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Unit width 400 mm, small footprint.Cooling capacity 953 (W/f) for chamber volume 6,1 m³ / 6100 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Cooling capacity 1577 (W/f) for chamber volume 16,3 m³ / 16300 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 1914 (W/f) for chamber volume 19,4 m³ / 19400 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 2343 (W/f) for chamber volume 29,2 m³ / 29200 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 2547 (W/f) for chamber volume 34,2 m³ / 34200 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity rendered 1960 (W/f) for chamber volume 16,4 m³ / 16400 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice formation. Refrigerant gas...
%
Cooling capacity rendered 3389 (W/f) for chamber volume 37,6 m³ / 37600 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice formation. Refrigerant gas...
%
Unit width 400 mm, small footprint.Cooling capacity rendered 975 (W/f) for chamber volume 6 m³ / 6000 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice...
%
Unit width 400 mm, small footprint.Cooling capacity rendered 1302 (W/f) for chamber volume 10,6 m³ / 10600 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent...
%
"Digital " electronic microprocessor (in closed box, 100% waterproof IP65) programmable at choice (including all HACCP functions), display on the front side4 choices of cycles " Soft Chill " or " Soft Freeze " for sensitive products_backup_1_1, " Hard-Chill " or " Hard-Freeze " for big pieces, control by timer with a bell at the end of the cycle (or) control by core probe, hold function at the end of the cycle and an alarm device (acoustic & visual)Stamped inside bottom, angles and...
%
Structuur in RVS AISI 304 18/10.Diepgetrokken waterdichte bodem, afgeronde hoeken.Openklapbaar "Flip-Flop" deksel beiderzijds.Met stootbumper.4 wielen, waarvan 2 zwenkwielen.
%
Glass doors (Thermopane®) 510 mm wide, useful passage 470xh737 mmLED lighting, on each doorInternal dimensions 2340x430x737 mm.2 rilsanized grids (450x430 mm) per door, adjustable, 3 interior storage (standing bottles) free height 737 mmLoad capacity in bottles 33cl = 588, in cans 33 cl = 840, 50 cl = 504Height without feet 820 mm4 adjustable feet (70 mm).Standard delivered with 4 central grids.Outside realization in Skinplate (color black), inside in Skinplate (color white), food guarantee...
%
Glass doors (Thermopane®) 510 mm wide, useful passage 470xh737 mmLED lighting, on each doorInternal dimensions 2340x430x737 mm.2 rilsanized grids (450x430 mm) per door, adjustable, 3 interior storage (standing bottles) free height 737 mmLoad capacity in bottles 33cl = 588, in cans 33 cl = 840, 50 cl = 504Height without feet 820 mm4 adjustable feet (70 mm).Standard delivered with 4 central grids.Outside cabinet made in stainless steel AISI 430 inner liner in stainless steel AISI 304.Interior...
%