High version, easier loading / unloading of baskets,..."Double-walled" Standard versionWith anti-pollution device, AB type (Break Tank), including rinse pump (atmospheric boiler)Load height 405 mmPlate height 380 mm3 stages: washing, discharge, rinseDrain pump, standardRinse pump, standard (atmospheric boiler) Double-walled version completely in stainless steel AISI 304. - From 60 till 24 baskets/hour, cycles 60'' - 120'' - 150" or continuous - Rotating wash and rinse arms (upper and lower),...
%
Low version, installation option under sinks and cupboards etc...."Double-walled" VersionWith anti-pollution device, AB type (Break Tank), including rinse pump (atmospheric boiler)Load height 405 mmPlate height 380 mm3 stages: washing, discharge, rinseDrain pump, standardRinse pump, standard (atmospheric boiler) Double-walled version completely in stainless steel AISI 304. - From 60 till 24 baskets/hour, cycles 60'' - 120'' - 150" or continuous - Rotating wash and rinse arms (upper and...
%
2 compressor groups and 2 evaporators, independent.Included: 2 grids GN 2/1 (530x650 mm) + 4 trays GN1/1-100 mm in polycarbonate.Fish refrigerator: evaporator at copper coil, embedded in the walls (3 sides), manual defrost, with water collecting tray, bottom fitted with a draining tap.4 adjustable stainless steel feet.Refrigerant Gas R290. Interior and exterior made of stainless steel (food grade) AISI 304 (rear galvanized steel), monocoque frameStainless steel racks and slides (antitilt),...
%
2 compressor groups and 2 evaporators, independent.Included: 2 x 2 grids GN2/1 (530x650 mm).Freezer: inner door fitted with warming resistance, copper coil evaporator, embedded in the walls (3 sides), manual defrost and depression valve, bottom fitted with a draining tap.4 adjustable stainless steel feet.Refrigerant gas R290 Interior and exterior made of stainless steel (food grade) AISI 304 (rear galvanized steel), monocoque frameStainless steel racks and slides (antitilt), allowing the...
%
Unit width 400 mm, small footprint.Cooling capacity 671 (W/f) for chamber volume 3,6 m³ / 3600 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Unit width 400 mm, small footprint.Cooling capacity 817 (W/f) for chamber volume 4,8 m³ / 4800 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Unit width 400 mm, small footprint.Cooling capacity 953 (W/f) for chamber volume 6,1 m³ / 6100 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Cooling capacity 1577 (W/f) for chamber volume 16,3 m³ / 16300 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 1914 (W/f) for chamber volume 19,4 m³ / 19400 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 2343 (W/f) for chamber volume 29,2 m³ / 29200 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 2547 (W/f) for chamber volume 34,2 m³ / 34200 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity rendered 1960 (W/f) for chamber volume 16,4 m³ / 16400 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice formation. Refrigerant gas...
%
Cooling capacity rendered 3389 (W/f) for chamber volume 37,6 m³ / 37600 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice formation. Refrigerant gas...
%
Unit width 400 mm, small footprint.Cooling capacity rendered 975 (W/f) for chamber volume 6 m³ / 6000 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice...
%
Unit width 400 mm, small footprint.Cooling capacity rendered 1302 (W/f) for chamber volume 10,6 m³ / 10600 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent...
%
Water softener continuously, incorporated (ATTENTION: cold water connection) Height of load Ø 465 mm.Realisation "double walled". with thermic insulation.From 60 to 24 baskets/hour, PLD cycles 60", 120", 150" or continuous.3 phases: wash, unload, rinse.Water consumption per cycle 3 liters.Vertical wash pump (double flux), auto-drain and auto-wash (1,5 Kw).Standard discharge pump.Standard rinse pump (atmospheric boiler) Control panel at the top of the hood, digital display.Basket 600x500 mm,...
%
Integration of the "Green System H.R.S." Condenser vapor-recovery unit, big energy savings (ATTENTION: connection to cold water)Watersofterner continuously, incorporated. (ATTENTION: connection to cold water)Height of load Ø 465 mmRealisation "double walled". with thermic insulation.From 60 to 24 baskets/hour, PLD cycles 60", 120", 150" or continuous.3 phases: wash, unload, rinse.Water consumption per cycle 3 liters.Standard discharge pump.Standard rinse pump (atmospheric boiler) Control...
%
2 drawers on telescopic slides.Condensate water collection tank underneath the unit.Refrigerant gas R452aMade of AISI 304 stainless steel.Adjustable stainless steel feet.Appliances built in compliance with current standards (CE)
%
2 drawers on telescopic slides.Condensate water collection tank underneath the unit.Refrigerant gas R290Made of AISI 304 stainless steel.Adjustable stainless steel feet.Appliances built in compliance with current standards (CE)
%
Refrigerator or freezer2 drawers on telescopic slides.Condensate water collection tray below the appliance.Refrigerant gas R290Made of stainless steel AISI 304.Adjustable stainless steel feet.Appliances built in compliance with current (CE) standards.