Realisation "double walled".Charging height glasses 300 mm. From 60-24 baskets/hour, cycle 60" - 120" - 150".Rotating wash and rinse arms (upper and below).Self cleaning sprinklers.Double wall door, "stamped", "removable" waterproof seal.Removable control panel.Automatic filling of the tank.Check valve.Hot water rinse (water consumption per cycle 2 liters), stainless steel boiler (2,6 Lit., 2,65 kW).Micro switch, when the door opens.Safety thermostat.Manufactured in stainless steel AISI...
%
Realisation "double walled".Version with incorporated water softener.Charging height glasses 300 mm. From 60-24 baskets/hour, cycle 60 - 120 - 150" .Rotating wash and rinse arms (upper and below).Self cleaning sprinklers.Double wall door, "stamped", "removable" waterproof seal.Removable control panel.Automatic filling of the tank.Check valve.Hot water rinse (water consumption per cycle 2 liters), stainless steel boiler (2,6 Lit., 2,65 kW).Micro switch, when the door opens.Safety...
%
Realisation "double walled".Version with incorporated discharge pump.Charging height glasses 300 mm. From 60-24 baskets/hour, cycle 60 - 120 - 150" .Rotating wash and rinse arms (upper and below).Self cleaning sprinklers.Double wall door, "stamped", "removable" waterproof seal.Removable control panel.Automatic filling of the tank.Check valve.Hot water rinse (water consumption per cycle 2 liters), stainless steel boiler (2,6 Lit., 2,65 kW).Micro switch, when the door opens.Safety...
%
Realisation "double walled".With anti-pollution device type AB (Break Tank), including the discharge pump (atmospheric boiler)Standard with disharge pump.Charging height glasses 300 mm. From 60-24 baskets/hour, cycle 60 - 120 - 150" .Rotating wash and rinse arms (upper and below).Self cleaning sprinklers.Double wall door, "stamped", "removable" waterproof seal.Removable control panel.Automatic filling of the tank.Check valve.Hot water rinse (water consumption per cycle 2 liters), stainless...
%
%
Charging height glasses 300 mm 30 baskets/hour,120-second cycle.Rotating wash and rinse arms (upper and lower).Self cleaning sprinklers.Tank, rounded edges (8 Lit., 0,6 kW).Stamped walls.Double walled door.Removable control panel.Automatic filling of the tank.Check valve.Hot water rinse (water consumption per cycle 2 liters), boiler (pressure) in stainless steel (2,6 Lit., 2,6 kW).Micro switch, when the door opens.Safety thermostat.Manufactured in stainless steel AISI 304.Standard: 2 baskets,...
%
Version with incorporated water softener.Charging height glasses 300 mm 30 baskets/hour,120-second cycle.Rotating wash and rinse arms (upper and lower).Self cleaning sprinklers.Tank, rounded edges (8 Lit., 0,6 kW).Stamped walls.Double walled door.Removable control panel.Automatic filling of the tank.Check valve.Hot water rinse (water consumption per cycle 2 liters), boiler (pressure) in stainless steel (2,6 Lit., 2,6 kW).Micro switch, when the door opens.Safety thermostat.Manufactured in...
%
Version with incorporated drain pumpCharging height glasses 300 mm 30 baskets/hour,120-second cycle.Rotating wash and rinse arms (upper and lower).Self cleaning sprinklers.Tank, rounded edges (8 Lit., 0,6 kW).Stamped walls.Double walled door.Removable control panel.Automatic filling of the tank.Check valve.Hot water rinse (water consumption per cycle 2 liters), boiler (pressure) in stainless steel (2,6 Lit., 2,6 kW).Micro switch, when the door opens.Safety thermostat.Manufactured in stainless...
%
Production unit combined with a storage unit.Production 400 kg per 24/h.Air condenser. Refrigerant cylinder system with scraper (continuous production).Very low temperature ice from -5°C to -10°C.Tropicalized hermetic unit ambient temperature + 43 °CRefrigerant gas R404a or R452a.Made of AISI 304 stainless steel.The device is built in compliance with all applicable standards (CE).
%
Production unit combined with a storage unit.Production 400 kg per 24/h.Air condenser. Refrigerant cylinder system with scraper (continuous production).Very low temperature ice from -5°C to -10°C.Tropicalized hermetic unit ambient temperature + 43 °Crefrigerant gas R404a or R452a per capillary..The device is built in compliance with all applicable standards (CE).
%
Production unit combined with a storage unit.Production 900 kg per 24/h.Air condenser.Refrigerant cylinder system with scraper(continuous production).Very low temperature ice from -5°C to -10°C.Tropicalized hermetic unit ambient temperature + 43 °CRefrigerant gas R404a or R452a Made of AISI 304 stainless steel.The device is built in compliance with the current CE standards.
%
Production unit combined with a storage unit.Production 900 kg per 24/h.Water condenser. Refrigerant cylinder system with scraper (continuous production).Very low temperature ice from -5°C to -10°C.Tropicalized hermetic unit ambient temperature + 43 °CRefrigerant gas R404a or R452a Made of AISI 304 stainless steel.The device is built in compliance with the current CE standards.
%
Temperature -1° +6° CRefrigerant R600aRoll bond evaporator, ventilated.Automatic defrost, self-evaporating condensate.Supplied with 2 (very sturdy) adjustable grids (493x392 mm). AISI 430 stainless steel exterior, white molded ABS interior.Glass door (Thermopane®), reversible, with aluminum frame, magnetic seal (snap-action), easy replacement without tools, very sturdy handle.LED interior lightKey lock as standardElectronic control, digital displayCFC-free expanded polyurethane insulation (60...
%