- Air condenser.- Vertical turbine, ideal for restaurants, requires little maintenance and is very easy to use. - Easy installation due to its compact size. - Minimum mixing capacity 0.5 lit. and maximum 1 lit. - Noise level lower than 70 dB. - Cycle with time control or temperature control. - Vertical evaporator cylinders for a larger exchange surface. - Exclusive distribution device. - System self diagnosis. - Cycle time: 15/20 min. - Hourly production: 5 liters. NB: mainly for cold work.
%
%
- Air condenser.- Vertical turbine with automatic extraction. - Minimum mixing capacity 2 litres and maximum 4 litres. - Noise level below 70 dB. - Vertical evaporator cylinders for a larger exchange surface. - Cycle with time control or temperature control. - Exclusive distribution device. - System self diagnosis. - Cycle time: 10/15 min. - Hourly production: 20 litres. NB: mainly for cold work, delivered on wheels.
%
%
%
%
- Air condenser.- Vertical turbine with automatic extraction. - Minimum mixing capacity 2 litres and maximum 4 litres. - Noise level below 70 dB. - Vertical evaporator cylinders for a larger exchange surface. - Cycle with time control or temperature control. - Exclusive distribution device. - System self diagnosis. - Cycle time: 10/15 min. - Hourly production: 20 litres. NB: mainly for cold work, delivered on wheels.
%
%
- Air condenser.- Vertical turbine with automatic extraction.- Minimum mixing capacity 3 lit. and maximum 7 lit.- Noise level below 70 dB.- Vertical evaporator cylinders for a larger exchange surface.- Cycle with time control or temperature control.- Exclusive distribution device. - System self diagnosis.- Cycle time: 8/12 min.- Hourly production: 50 litres.NB: mainly for cold work
%
%
- Air condenser.- Vertical turbine with automatic extraction.- Minimum mixing capacity 3 lit. and maximum 7 lit.- Noise level below 70 dB.- Vertical evaporator cylinders for a larger exchange surface.- Cycle with time control or temperature control.- Exclusive distribution device. - System self diagnosis.- Cycle time: 8/12 min.- Hourly production: 50 litres.NB: mainly for cold work.
%
%
- Water condenser.- Vertical turbine with automatic extraction.- Minimum mixing capacity 3 lit. and maximum 7 lit.- Noise level below 70 dB.- Vertical evaporator cylinders for a larger exchange surface.- Cycle with time control or temperature control.- Exclusive distribution device. - System self diagnosis.- Cycle time: 8/12 min.- Hourly production: 50 litres.NB: mainly for cold work.
%
%
%
Vacuum pump capacity 63m3/h (Busch type).Cycle time 15-40 seconds.Aluminium cover with window.Chamber dimensions: 2x 450x580xh235 mm.Working height 900 mm.4 sealing bars (2 per chamber).Digital control panel with 10 programs, analog display.On request: inclined plate for liquid products, gas injection system "nitrogen", Soft air: gradual vacuuming, ....Professional machines on pedestal.The vacuum is managed in % thanks to the integrated vacuum sensor, no more risk of inadvertent incomplete...
%
- Air condenser.- Vertical turbine with automatic extraction.- Minimum mixing capacity 4 lit. and maximum 8 lit.- Noise level below 70 dB.- Vertical evaporator cylinders for a larger exchange surface.- Cycle with time control or temperature control.- Exclusive distribution device. - System self diagnosis. - Cycle time: 8/12 min. - Hourly production: 60 litres.NB: mainly for cold work.
%
Vacuum pump capacity 100m3/h (Busch type).Cycle time 15-40 seconds.Stainless steel cover.Chamber dimensions: 2x 620x500xh240 mm (Sealing length: 4 x 620mm).Working height 900 mm.4 sealing bars (2 per chamber)Digital control panel with 10 programs, maintenance program and pump cleaning.Soft air: gradual vacuuming.On request: gas injection system "nitrogen", ....Professional machines on pedestals.Vacuum is managed in % thanks to the integrated vacuum sensor, no more risk of inadvertent...
%
- Air condenser.- Vertical turbine with automatic extraction.- Minimum mixing capacity 4 lit. and maximum 8 lit.- Noise level below 70 dB.- Vertical evaporator cylinders for a larger exchange surface.- Cycle with time control or temperature control.- Exclusive distribution device. - System self diagnosis. - Cycle time: 8/12 min. - Hourly production: 60 litres.NB: mainly for cold work.
%
%
- Water condenser- Vertical turbine with automatic extraction.- Minimum mixing capacity 4 lit. and maximum 8 lit.- Noise level below 70 dB.- Vertical evaporator cylinders for a larger exchange surface.- Cycle with time control or temperature control.- Exclusive distribution device. - System self diagnosis. - Cycle time: 8/12 min. - Hourly production: 60 litres.NB: mainly for cold work.
%
Vacuum pump capacity 160m3/h (Busch type).Cycle time 15-40 seconds.Stainless steel cover.Chamber dimensions: 2x 620x750xh210 mm (Sealing length: 4 x 620mm).Working height 900 mm.4 sealing bars (2 per chamber)Digital control panel with 10 programs, maintenance program and pump cleaning.Soft air: gradual vacuuming.On request: gas injection system "nitrogen", ....Professional machines on pedestals.Vacuum is managed in % thanks to the integrated vacuum sensor, no more risk of inadvertent...
%
- Water condenser- Vertical turbine with automatic extraction.- Minimum mixing capacity 4 lit. and maximum 8 lit.- Noise level below 70 dB.- Vertical evaporator cylinders for a larger exchange surface.- Cycle with time control or temperature control.- Exclusive distribution device. - System self diagnosis. - Cycle time: 8/12 min. - Hourly production: 60 litres.NB: mainly for cold work.
%
Vacuum pump capacity 250m3/h (Busch type).Cycle time 15-30 seconds.Stainless steel cover.Chamber dimensions: 2x 840x830xh250 mm (Sealing length: 4 x 840mm).Working height 900 mm.4 sealing bars (2 per chamber)Digital control panel with 10 programs, maintenance program and pump cleaning.Soft air: gradual vacuuming.On request: gas injection system "nitrogen", ....Professional machines on pedestals.Vacuum is managed in % thanks to the integrated vacuum sensor, no more risk of inadvertent...