%
- Air condenser.- Vertical turbine, ideal for restaurants, requires little maintenance and is very easy to use. - Easy installation due to its compact size. - Minimum mixing capacity 0.5 lit. and maximum 1 lit. - Noise level lower than 70 dB. - Cycle with time control or temperature control. - Vertical evaporator cylinders for a larger exchange surface. - Exclusive distribution device. - System self diagnosis. - Cycle time: 15/20 min. - Hourly production: 5 liters. NB: mainly for cold work.
%
Recommended for machines with rinsing pump or "Break Tank" device.Productivity 150 Lit/h (water 15°C).3 separate compartments, hydraulic, inspection (front), electric.Pressure gauge(s) to display the water pressure.Membrane removable from the front.Activated charcoal filter, including by-pass function. Made of stainless steel.
%
%
- Air condenser.- Vertical turbine with automatic extraction. - Minimum mixing capacity 2 litres and maximum 4 litres. - Noise level below 70 dB. - Vertical evaporator cylinders for a larger exchange surface. - Cycle with time control or temperature control. - Exclusive distribution device. - System self diagnosis. - Cycle time: 10/15 min. - Hourly production: 20 litres. NB: mainly for cold work, delivered on wheels.
%
With expansion tank (5,5 Lit. at 3 bar), for all kind of machines.Productivity 150 Lit/h (water 15°C).3 separate compartments, hydraulic, inspection (front), electric.Pressure gauge(s) to display the water pressure.Membrane removable from the front.Activated charcoal filter, including by-pass function. Made of stainless steel.
%
%
%
%
%
- Air condenser.- Vertical turbine with automatic extraction. - Minimum mixing capacity 2 litres and maximum 4 litres. - Noise level below 70 dB. - Vertical evaporator cylinders for a larger exchange surface. - Cycle with time control or temperature control. - Exclusive distribution device. - System self diagnosis. - Cycle time: 10/15 min. - Hourly production: 20 litres. NB: mainly for cold work, delivered on wheels.
%
Interior lighting.Electronic thermostat, automatic defrosting. For GN trays with a maximum depth of 100 mm, or pastry plates 600x400 mm. Intermediant grid 945x400 mm, curved glass and side walls, removable (maintainability). Sliding doors on the service side. Made in stainless steel.NB: delivered without trays.
%
- Air condenser.- Vertical turbine with automatic extraction.- Minimum mixing capacity 3 lit. and maximum 7 lit.- Noise level below 70 dB.- Vertical evaporator cylinders for a larger exchange surface.- Cycle with time control or temperature control.- Exclusive distribution device. - System self diagnosis.- Cycle time: 8/12 min.- Hourly production: 50 litres.NB: mainly for cold work
%
Made of lacquered steel, BLACK.Capacity: EN 400x600 or GN 1/1.Internal dimensions: 1065x620xh410 mm.2 glass shelves 1045x490 mm. Made of lacquered steel, or stainless steel.External double glazing glass (Thermopane®).Stainless steel bottom plates (removable).4 internal lightning type LED, with switch. 2 display shelves (removable) in tempered glass (0,4mm).Sliding doors on the service side, removable (easy maintenance).Ventilated refrigeration, homogeneous temperature.Built-in compressor...
%
- Air condenser.- Vertical turbine with automatic extraction.- Minimum mixing capacity 3 lit. and maximum 7 lit.- Noise level below 70 dB.- Vertical evaporator cylinders for a larger exchange surface.- Cycle with time control or temperature control.- Exclusive distribution device. - System self diagnosis.- Cycle time: 8/12 min.- Hourly production: 50 litres.NB: mainly for cold work.
%
Made of lacquered steel, BLACK.Capacity: EN 400x600 or GN 1/1.Internal dimensions: 665x620xh410 mm.2 glass shelves 645x490 mm. Made of lacquered steel, or stainless steel.External double glazing glass (Thermopane®).Stainless steel bottom plates (removable).4 internal lightning type LED, with switch.2 display shelves (removable) in tempered glass (0,4mm).Sliding doors on the service side, removable (easy maintenance).Ventilated refrigeration, homogeneous temperature.Built-in compressor unit,...
%
- Water condenser.- Vertical turbine with automatic extraction.- Minimum mixing capacity 3 lit. and maximum 7 lit.- Noise level below 70 dB.- Vertical evaporator cylinders for a larger exchange surface.- Cycle with time control or temperature control.- Exclusive distribution device. - System self diagnosis.- Cycle time: 8/12 min.- Hourly production: 50 litres.NB: mainly for cold work.
%
%
- Air condenser.- Vertical turbine with automatic extraction.- Minimum mixing capacity 4 lit. and maximum 8 lit.- Noise level below 70 dB.- Vertical evaporator cylinders for a larger exchange surface.- Cycle with time control or temperature control.- Exclusive distribution device. - System self diagnosis. - Cycle time: 8/12 min. - Hourly production: 60 litres.NB: mainly for cold work.
%
- Air condenser.- Vertical turbine with automatic extraction.- Minimum mixing capacity 4 lit. and maximum 8 lit.- Noise level below 70 dB.- Vertical evaporator cylinders for a larger exchange surface.- Cycle with time control or temperature control.- Exclusive distribution device. - System self diagnosis. - Cycle time: 8/12 min. - Hourly production: 60 litres.NB: mainly for cold work.
%
- Water condenser- Vertical turbine with automatic extraction.- Minimum mixing capacity 4 lit. and maximum 8 lit.- Noise level below 70 dB.- Vertical evaporator cylinders for a larger exchange surface.- Cycle with time control or temperature control.- Exclusive distribution device. - System self diagnosis. - Cycle time: 8/12 min. - Hourly production: 60 litres.NB: mainly for cold work.
%
- Water condenser- Vertical turbine with automatic extraction.- Minimum mixing capacity 4 lit. and maximum 8 lit.- Noise level below 70 dB.- Vertical evaporator cylinders for a larger exchange surface.- Cycle with time control or temperature control.- Exclusive distribution device. - System self diagnosis. - Cycle time: 8/12 min. - Hourly production: 60 litres.NB: mainly for cold work.
%
- Air condenser.- Vertical turbine with automatic extraction, low maintenance and very easy to use.- Easy installation due to its compact size.- Minimum mixing capacity 1 liter and maximum 2 liters.- Noise level below 70 dB.- Cycle with time control or with temperature control.- Vertical cylinders-evaporators for a bigger surface of exchange.- Exclusive dispensing device.- Auto diagnostic system.- Cycle time: 10/20 min.- Hourly production: 12 liters.NB: mainly for cold work.
%
- Air condenser.- Vertical turbine with automatic extraction, low maintenance and very easy to use.- Easy installation due to its compact size.- Minimum mixing capacity 1 liter and maximum 2 liters.- Noise level below 70 dB.- Cycle with time control or with temperature control.- Vertical cylinders-evaporators for a bigger surface of exchange.- Exclusive dispensing device.- Auto diagnostic system.- Cycle time: 10/20 min.- Hourly production: 12 liters.NB: mainly for cold work.
%
- Water condenser.- Vertical turbine with automatic extraction. - Minimum mixing capacity 7 lit. and maximum 12 lit. - Noise level below 70 dB. - Vertical evaporator cylinders for a larger exchange surface. - Cycle with time control or temperature control. - Exclusive distribution device. - System self diagnosis. - Cycle time: 8/12 min. - Hourly production: 75 litres. NB: mainly for cold work.