- Air condenser.- Vertical turbine, ideal for restaurants, requires little maintenance and is very easy to use. - Easy installation due to its compact size. - Minimum mixing capacity 0.5 lit. and maximum 1 lit. - Noise level lower than 70 dB. - Cycle with time control or temperature control. - Vertical evaporator cylinders for a larger exchange surface. - Exclusive distribution device. - System self diagnosis. - Cycle time: 15/20 min. - Hourly production: 5 liters. NB: mainly for cold work.
%
- Structures with slides for plates (2x8 levels) included, double row (600x400 EN or 530x325 GN1/1) - 2 glass doors- Structure for plates (74 mm), removable- Door in tempered glass (6 mm) with stainless steel handle- Heating through stainless steel armoured resistances- Adjustable slides- GN vat inside (on the bottom), tu put water and to humidify the cupboard- On/off switch- Mechanical thermosat (30° to 60°C) with pilot light- Manufactured in stainless steel- Adjustable stainless steel feet-...
Four-burner stove with legs.9KW per nozzle.More info on request.
%
- Air condenser.- Vertical turbine with automatic extraction. - Minimum mixing capacity 2 litres and maximum 4 litres. - Noise level below 70 dB. - Vertical evaporator cylinders for a larger exchange surface. - Cycle with time control or temperature control. - Exclusive distribution device. - System self diagnosis. - Cycle time: 10/15 min. - Hourly production: 20 litres. NB: mainly for cold work, delivered on wheels.
%
- Structures with slides for plates (2x6 levels) included, double row (600x400 EN or 530x325 GN1/1) - 2 glass doors- Structure for plates (74 mm), removable- Door in tempered glass (6 mm) with stainless steel handle- Heating through stainless steel armoured resistances- Adjustable slides- GN vat inside (on the bottom), tu put water and to humidify the cupboard- On/off switch- Mechanical thermosat (30° to 60°C) with pilot light- Manufactured in stainless steel- Adjustable stainless steel feet-...
Oven on six-burner base.9KW per nozzle.More info on request.
%
%
- Structures with slides for plates (8 levels) included, double row (600x400 EN ou 530x325 GN1/1) - 2 glass doors- Structure for plates (74 mm), removable- Door in tempered glass (6 mm) with stainless steel handle- Heating through stainless steel armoured resistances- Adjustable slides- GN vat inside (on the bottom), tu put water and to humidify the cupboard- On/off switch- Mechanical thermosat (30° to 60°C) with pilot light- Manufactured in stainless steel- Adjustable stainless steel feet-...
8 burner stove under the base.9Kw per nozzlemore info on request.
%
- Air condenser.- Vertical turbine with automatic extraction.- Minimum mixing capacity 3 lit. and maximum 7 lit.- Noise level below 70 dB.- Vertical evaporator cylinders for a larger exchange surface.- Cycle with time control or temperature control.- Exclusive distribution device. - System self diagnosis.- Cycle time: 8/12 min.- Hourly production: 50 litres.NB: mainly for cold work
%
- Structures with slides for plates (8 levels) included (460x340 or 433x333 or 353x325 GN2/3) - Glass door- Structure for plates (74 mm), removable- Door in tempered glass (6 mm) with stainless steel handle- Heating through stainless steel armoured resistances- Adjustable slides- GN vat inside (on the bottom), tu put water and to humidify the cupboard- On/off switch- Mechanical thermosat (30° to 60°C) with pilot light- Manufactured in stainless steel- Adjustable stainless steel feet-...
Stove on base with 4 spouts.2 nozzles of 9 Kw.2 nozzles of 17Kw.more info on request.
%
Structures with slides for plates (8 levels) included, double row (600x400 EN ou 530x325 GN1/1)2 glass doors Structure for plates (74 mm), removable.Door in tempered glass (6 mm) with stainless steel handleHeating through stainless steel armoured resistancesAdjustable slidesGN vat inside (on the bottom), to put water and to humidify the cupboardOn/off switchMechanical thermosat (30° to 60°C) with pilot lightManufactured in stainless steelAdjustable stainless steel feetEquipment manufactured...
%
- Air condenser.- Vertical turbine with automatic extraction.- Minimum mixing capacity 3 lit. and maximum 7 lit.- Noise level below 70 dB.- Vertical evaporator cylinders for a larger exchange surface.- Cycle with time control or temperature control.- Exclusive distribution device. - System self diagnosis.- Cycle time: 8/12 min.- Hourly production: 50 litres.NB: mainly for cold work.
%
%
Structures with slides for plates (8 levels) included (460x340 or 433x333 or 353x325 GN2/3)Glass door Structure for plates (74 mm), removableDoor in tempered glass (6 mm) with stainless steel handleHeating through stainless steel armoured resistancesAdjustable slidesGN vat inside (on the bottom), tu put water and to humidify the cupboardOn/off switchMechanical thermosat (30° to 60°C) with pilot lightManufactured in stainless steelAdjustable stainless steel feetEquipment manufactured following...
%
- Water condenser.- Vertical turbine with automatic extraction.- Minimum mixing capacity 3 lit. and maximum 7 lit.- Noise level below 70 dB.- Vertical evaporator cylinders for a larger exchange surface.- Cycle with time control or temperature control.- Exclusive distribution device. - System self diagnosis.- Cycle time: 8/12 min.- Hourly production: 50 litres.NB: mainly for cold work.
%
%
- Air condenser.- Vertical turbine with automatic extraction.- Minimum mixing capacity 4 lit. and maximum 8 lit.- Noise level below 70 dB.- Vertical evaporator cylinders for a larger exchange surface.- Cycle with time control or temperature control.- Exclusive distribution device. - System self diagnosis. - Cycle time: 8/12 min. - Hourly production: 60 litres.NB: mainly for cold work.
%
- Air condenser.- Vertical turbine with automatic extraction.- Minimum mixing capacity 4 lit. and maximum 8 lit.- Noise level below 70 dB.- Vertical evaporator cylinders for a larger exchange surface.- Cycle with time control or temperature control.- Exclusive distribution device. - System self diagnosis. - Cycle time: 8/12 min. - Hourly production: 60 litres.NB: mainly for cold work.
%
- Water condenser- Vertical turbine with automatic extraction.- Minimum mixing capacity 4 lit. and maximum 8 lit.- Noise level below 70 dB.- Vertical evaporator cylinders for a larger exchange surface.- Cycle with time control or temperature control.- Exclusive distribution device. - System self diagnosis. - Cycle time: 8/12 min. - Hourly production: 60 litres.NB: mainly for cold work.
%
- Water condenser- Vertical turbine with automatic extraction.- Minimum mixing capacity 4 lit. and maximum 8 lit.- Noise level below 70 dB.- Vertical evaporator cylinders for a larger exchange surface.- Cycle with time control or temperature control.- Exclusive distribution device. - System self diagnosis. - Cycle time: 8/12 min. - Hourly production: 60 litres.NB: mainly for cold work.
%
- Air condenser.- Vertical turbine with automatic extraction, low maintenance and very easy to use.- Easy installation due to its compact size.- Minimum mixing capacity 1 liter and maximum 2 liters.- Noise level below 70 dB.- Cycle with time control or with temperature control.- Vertical cylinders-evaporators for a bigger surface of exchange.- Exclusive dispensing device.- Auto diagnostic system.- Cycle time: 10/20 min.- Hourly production: 12 liters.NB: mainly for cold work.
%
- Air condenser.- Vertical turbine with automatic extraction, low maintenance and very easy to use.- Easy installation due to its compact size.- Minimum mixing capacity 1 liter and maximum 2 liters.- Noise level below 70 dB.- Cycle with time control or with temperature control.- Vertical cylinders-evaporators for a bigger surface of exchange.- Exclusive dispensing device.- Auto diagnostic system.- Cycle time: 10/20 min.- Hourly production: 12 liters.NB: mainly for cold work.