- Air condenser.- Vertical turbine, ideal for restaurants, requires little maintenance and is very easy to use. - Easy installation due to its compact size. - Minimum mixing capacity 0.5 lit. and maximum 1 lit. - Noise level lower than 70 dB. - Cycle with time control or temperature control. - Vertical evaporator cylinders for a larger exchange surface. - Exclusive distribution device. - System self diagnosis. - Cycle time: 15/20 min. - Hourly production: 5 liters. NB: mainly for cold work.
%
%
- Capacity : 4 ice tray of 6,5 lit., 5 lit., 3 lit. or 8 ice tray of 2,5 lit.- Structure made of ABS white, plexiglas lid.- Copper evaporator.- Gas cooling R404a.- Insulation without "CFC".- Maintenance and maintains easy.NB: delivered without ice trays.
%
- Air condenser.- Vertical turbine with automatic extraction. - Minimum mixing capacity 2 litres and maximum 4 litres. - Noise level below 70 dB. - Vertical evaporator cylinders for a larger exchange surface. - Cycle with time control or temperature control. - Exclusive distribution device. - System self diagnosis. - Cycle time: 10/15 min. - Hourly production: 20 litres. NB: mainly for cold work, delivered on wheels.
%
%
- Capacity : 4 ice tray of 6,5 lit., 5 lit., 3 lit. or 8 ice tray of 2,5 lit.- Structure made of ABS, plexiglas lid.- Copper evaporator.- Gas cooling R290.- Insulation without "CFC".- Maintenance and maintains easy.NB: delivered without ice trays.
%
%
%
Temperature: +2° +10°Hermetic cool unit (surrounding temperature t° +32°C).Polyuretan insulation without CFC.Serpentine copper evaporator placed inside the walls.Refrigerant gas R600a.Electronic thermostat.Automatic defrosting by hot gas with auto-evaporation.Manufactured in moulded ABS of food quality.Appliances are complied with the CE in force.N.B: delivered without containers.
%
- Air condenser.- Vertical turbine with automatic extraction.- Minimum mixing capacity 3 lit. and maximum 7 lit.- Noise level below 70 dB.- Vertical evaporator cylinders for a larger exchange surface.- Cycle with time control or temperature control.- Exclusive distribution device. - System self diagnosis.- Cycle time: 8/12 min.- Hourly production: 50 litres.NB: mainly for cold work
%
Minimum height : 16cmMaximum height : 23cm
%
- Air condenser.- Vertical turbine with automatic extraction.- Minimum mixing capacity 3 lit. and maximum 7 lit.- Noise level below 70 dB.- Vertical evaporator cylinders for a larger exchange surface.- Cycle with time control or temperature control.- Exclusive distribution device. - System self diagnosis.- Cycle time: 8/12 min.- Hourly production: 50 litres.NB: mainly for cold work.
%
%
- Water condenser.- Vertical turbine with automatic extraction.- Minimum mixing capacity 3 lit. and maximum 7 lit.- Noise level below 70 dB.- Vertical evaporator cylinders for a larger exchange surface.- Cycle with time control or temperature control.- Exclusive distribution device. - System self diagnosis.- Cycle time: 8/12 min.- Hourly production: 50 litres.NB: mainly for cold work.
%
%
%
%
- Air condenser.- Vertical turbine with automatic extraction.- Minimum mixing capacity 4 lit. and maximum 8 lit.- Noise level below 70 dB.- Vertical evaporator cylinders for a larger exchange surface.- Cycle with time control or temperature control.- Exclusive distribution device. - System self diagnosis. - Cycle time: 8/12 min. - Hourly production: 60 litres.NB: mainly for cold work.
%
%
- Air condenser.- Vertical turbine with automatic extraction.- Minimum mixing capacity 4 lit. and maximum 8 lit.- Noise level below 70 dB.- Vertical evaporator cylinders for a larger exchange surface.- Cycle with time control or temperature control.- Exclusive distribution device. - System self diagnosis. - Cycle time: 8/12 min. - Hourly production: 60 litres.NB: mainly for cold work.
%
Delivered with stainless steel lidDelivered with standard slides 4x 1/4 and 1x 1/8.NB: delivered without pans GN.. Manufactured in stainless steel austenitic.- Electronic thermostat in closed box, waterproof.. Evaporator tubes integrated in the walls and bottom, polyurethane insulation, without CFC's.. Refrigerant R600a.. Compressor group in climate class 4 (at right side).. Ventilated condensor, with anti-fat filter protection.. Manufactured following the (CE) standards in force
%
- Water condenser- Vertical turbine with automatic extraction.- Minimum mixing capacity 4 lit. and maximum 8 lit.- Noise level below 70 dB.- Vertical evaporator cylinders for a larger exchange surface.- Cycle with time control or temperature control.- Exclusive distribution device. - System self diagnosis. - Cycle time: 8/12 min. - Hourly production: 60 litres.NB: mainly for cold work.
%
Delivered with "toughened" glass on top.Delivered with standard slides 4x 1/4 and 1x 1/8.NB: delivered without pans GN.. Manufactured in stainless steel austenitic.- Electronic thermostat in closed box, waterproof.. Evaporator tubes integrated in the walls and bottom, polyurethane insulation, without CFC's.. Refrigerant R600a.. Compressor group in climate class 4 (at right side).. Ventilated condensor, with anti-fat filter protection.. Manufactured following the (CE) standards in force
%
- Water condenser- Vertical turbine with automatic extraction.- Minimum mixing capacity 4 lit. and maximum 8 lit.- Noise level below 70 dB.- Vertical evaporator cylinders for a larger exchange surface.- Cycle with time control or temperature control.- Exclusive distribution device. - System self diagnosis. - Cycle time: 8/12 min. - Hourly production: 60 litres.NB: mainly for cold work.