Interior volume 9831 liters.Useful passage 720xh1860 mm. Galvanized steel panel recovered with a non-toxic plastic white film, food quality, polyurethane insulation injected at high density, eco-friendly (without CFC).Thickness of the wall, floor and ceiling = 80 mm.Locking of the panel by built-in "eccentric-gear" hooks.Anti-slip stainless steel floor.The angles and the corners of the floor, the ceiling and the walls are all at 135°, "sanitary".Very strong "bulging" door, reversible,...
%
Designed in stainless steel.ON/OFF switch.Shielded steel element heating, "hard-wearing".Strengthened protection cables for a better security without affecting the heat distribution.
%
Galvanized steel panels covered with a "non-toxic" white plastic film, food grade, high density injected polyurethane insulation, ecological (CFC-free).Wall, floor and ceiling thickness = 100 mm.Locking of the panels by built-in "eccentric" hooks.Stainless steel floor "non-slip".The corners and corners of the floor, sky and walls are all at 135° "sanitary".Very robust door, reversible, useful passage 900xh1860, closing by magnetic "pressure" seal (easy replacement, without tools), hinges with...
%
Designed in stainless steel.ON/OFF switch.Shielded steel element heating.Strengthened protection cables for a better security, without affecting the heat distributionLateral supports for heating bridge.Chromium-plated feet, in the shape of "C".Free space underneath the heating bridge: 343 mm.
%
Panels in galvanized steel covered with a white plastic film "not toxic", alimentary quality, isolation in injected polyurethane, high density, ecologic (w/o CFC's).Walls, floor and ceiling thickness = 100 mm.Locking of the panel by built-in "eccentric-gear" hooks.Floor in stainless steel. "anti-slip".Angles and corners of the floor, ceiling and floors, all at 135° '"sanitized".Very robust door, reversible, useful space 920xh1860, lock secured by magnetic seal "by pressure" (easy replacement...
%
Fitted with ceramic heating elements, ON/OFF switch.Incandescent lights.Very solid breath barrier (right).Heating base plate, gradual regulation of the heat intensity.
%
Panels in galvanized steel covered with a white plastic film "not toxic", alimentary quality, isolation in injected polyurethane, high density, ecologic (w/o CFC's).Walls, floor and ceiling thickness = 100 mm.Locking of the panel by built-in "eccentric-gear" hooks.Floor in stainless steel. "anti-slip".Angles and corners of the floor, ceiling and floors, all at 135° '"sanitized".Very robust door, reversible, useful space 920xh1860, lock secured by magnetic seal "by pressure" (easy replacement...
%
Model to put down."Toggle" switch.Free space underneath the 356 mm heating bridge.Base for GN 1/1.Infrared heating element above the tray, ON/OFF switch.Electric cable, 1829 mm, with plug.
%
Interior volume 10182 liters.Useful passage 720xh1860mm Galvanized steel panel recovered with a non-toxic plastic white film, food quality, polyurethane insulation injected at high density, eco-friendly (without CFC).Thickness of the wall, floor and ceiling = 80 mm.Locking of the panel by built-in "eccentric-gear" hooks.Anti-slip stainless steel floor.The angles and the corners of the floor, the ceiling and the walls are all at 135°, "sanitary".Very strong "bulging" door, reversible,...
%
Model to put down."Toggle" switch.Free space underneath the 356 mm heating bridge.Base for GN 1/1 sterilizer.Infrared heating element above the plate, ON/OFF switch.Electric cable, 1829 mm, with plug.
%
%
Designed in stainless steel.ON / OFF switchShielded steel element heating.Strengthened protection cable for a better security, without affecting the heat distribution.With suspension chains.
%
Interior volume 13037 liters.Useful passage 720xh1860mm Galvanized steel panel recovered with a non-toxic plastic white film, food quality, polyurethane insulation injected at high density, eco-friendly (without CFC).Thickness of the wall, floor and ceiling = 80 mm.Locking of the panel by built-in "eccentric-gear" hooks.Anti-slip stainless steel floor.The angles and the corners of the floor, the ceiling and the walls are all at 135°, "sanitary".Very strong "bulging" door, reversible,...
%
Designed in stainless steel.ON / OFF switchShielded steel element heating.Strengthened protection cable for a better security, without affecting the heat distribution.With suspension chains.
%
Interior volume 11434 liters.Useful passage 720xh1860 mm. Galvanized steel panel recovered with a non-toxic plastic white film, food quality, polyurethane insulation injected at high density, eco-friendly (without CFC).Thickness of the wall, floor and ceiling = 100 mm.Locking of the panel by built-in "eccentric-gear" hooks.Anti-slip stainless steel floor.The angles and the corners of the floor, the ceiling and the walls are all at 135°, "sanitary".Very strong "bulging" door, reversible,...
%
Designed in stainless steel.ON / OFF switchShielded steel element heating.Strengthened protection cable for a better security, without affecting the heat distributionWith suspension chains.
%
Interior volume 11610 liters.Useful passage 720xh1860 mm. Galvanized steel panel recovered with a non-toxic plastic white film, food quality, polyurethane insulation injected at high density, eco-friendly (without CFC).Thickness of the wall, floor and ceiling = 100 mm.Locking of the panel by built-in "eccentric-gear" hooks.Anti-slip stainless steel floor.The angles and the corners of the floor, the ceiling and the walls are all at 135°, "sanitary".Very strong "bulging" door, reversible,...
%
Fitted with ceramic heating elements, ON/OFF switch.Incandescent lights.Very solid breath barrier (right).Neutral base plate.
%
Unit width 400 mm, small footprint.Cooling capacity 671 (W/f) for chamber volume 3,6 m³ / 3600 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
%
Unit width 400 mm, small footprint.Cooling capacity 817 (W/f) for chamber volume 4,8 m³ / 4800 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
%
Unit width 400 mm, small footprint.Cooling capacity 953 (W/f) for chamber volume 6,1 m³ / 6100 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...