%
- Air condenser.- Vertical turbine, ideal for restaurants, requires little maintenance and is very easy to use. - Easy installation due to its compact size. - Minimum mixing capacity 0.5 lit. and maximum 1 lit. - Noise level lower than 70 dB. - Cycle with time control or temperature control. - Vertical evaporator cylinders for a larger exchange surface. - Exclusive distribution device. - System self diagnosis. - Cycle time: 15/20 min. - Hourly production: 5 liters. NB: mainly for cold work.
%
In-line wok burner Ø 290 mm (21.44 kW).Deep-drawn and waterproof cooking surface used to channel water for the cooling of the top.Lateral water drainage, equipped with an overflow drain.1 control valve per burner, connection (gas 1/2").Recuperation drawers.Made of AISI 441 stainless steel, Top of AISI 304 stainless steel (20/10th).
%
Included: 20 pairs of runners (400 x 600 mm).Inner door with heating resistance and under-pressure valve.4 adjustable stainless steel feet.Cooling gas R134.Interior and exterior made of (food) stainless steel AISI 304 (back made of galvanized steel), monocoque frame.Racks and rails in stainless steel (maximal capacity 27 slides, 50-mm spacing), which help to position the trays as one pleases, stamped inside bottom, with drain plug (major maintenance) and rounded angles and corners (without...
%
- Air condenser.- Vertical turbine with automatic extraction. - Minimum mixing capacity 2 litres and maximum 4 litres. - Noise level below 70 dB. - Vertical evaporator cylinders for a larger exchange surface. - Cycle with time control or temperature control. - Exclusive distribution device. - System self diagnosis. - Cycle time: 10/15 min. - Hourly production: 20 litres. NB: mainly for cold work, delivered on wheels.
%
In-line wok type burners Ø 290 mm (21.44 kW).Deep-drawn and waterproof cooking surface used to channel water for cooling the top.Lateral water drainage, equipped with an overflow drain.1 control valve per burner, connection (gas 3/4").Recuperation drawers.Made of AISI 441 stainless steel, Top of AISI 304 stainless steel (20/10th).
%
Included: 20 pairs of runners (600 x 800 mm).Inner door with heating resistance and under-pressure valve.4 adjustable stainless steel feet.Cooling gas R134.Interior and exterior made of (food) stainless steel AISI 304 (back made of galvanized steel), monocoque frame.Racks and rails in stainless steel (maximal capacity 27 slides, 50-mm spacing), which help to position the trays as one pleases, stamped inside bottom, with drain plug (major maintenance) and rounded angles and corners (without...
%
%
Burners type wok 2x Ø 290 mm 21,44 kW and 1x Ø 230 mm 10,13 kW.Embedded cooking top, catching basin underneath.Lateral drain, pouring basin with removable filter, foreseen of a cover and a drain hole.1 control vane per burner, gas connection (3/4").Water curtain for the cooling of the top, inclusive a tap and a ranging rack.Made of AISI 441 stainless steel, Top of AISI 304 stainless steel (20/10th).
%
Included: 20 pairs of runners (400 x 600 mm).4 adjustable stainless steel feet.Cooling gas R134.Interior and exterior made of (food) stainless steel AISI 304 (back made of galvanized steel), monocoque frame.Racks and rails in stainless steel (maximal capacity 27 slides, 50-mm spacing), which help to position the trays as one pleases, stamped inside bottom, with drain plug (major maintenance) and rounded angles and corners (without bumps).Doors with ergonomic (not projecting) and reversible...
%
- Air condenser.- Vertical turbine with automatic extraction.- Minimum mixing capacity 3 lit. and maximum 7 lit.- Noise level below 70 dB.- Vertical evaporator cylinders for a larger exchange surface.- Cycle with time control or temperature control.- Exclusive distribution device. - System self diagnosis.- Cycle time: 8/12 min.- Hourly production: 50 litres.NB: mainly for cold work
%
In-line wok type burners Ø 290 mm 21,44 kW.Deep-drawn and waterproof cooking surface used to channel water for cooling the top.Lateral water drainage, equipped with an overflow drain.1 control valve per burner, connection (gas 3/4").Recuperation drawers.Made of AISI 441 stainless steel, Top of AISI 304 stainless steel (20/10th).
%
Included: 20 pairs of runners (600 x 800 mm).4 adjustable stainless steel feet.Cooling gas R134.Interior and exterior made of (food) stainless steel AISI 304 (back made of galvanized steel), monocoque frame.Racks and rails in stainless steel (maximal capacity 27 slides, 50-mm spacing), which help to position the trays as one pleases, stamped inside bottom, with drain plug (major maintenance) and rounded angles and corners (without bumps).Doors with ergonomic (not projecting) and reversible...
%
%
- Air condenser.- Vertical turbine with automatic extraction.- Minimum mixing capacity 3 lit. and maximum 7 lit.- Noise level below 70 dB.- Vertical evaporator cylinders for a larger exchange surface.- Cycle with time control or temperature control.- Exclusive distribution device. - System self diagnosis.- Cycle time: 8/12 min.- Hourly production: 50 litres.NB: mainly for cold work.
%
Burners type wok 3x Ø 290 mm 21,44 kW and 2x Ø 230 mm 10,13 kW.Embedded cooking top, catching basin underneath.Lateral drain, pouring basin with removable filter, foreseen of a cover and a drain hole.1 control vane per burner, gas connection (4/4").Water curtain for the cooling of the top, inclusive a tap and a ranging rack.Made of AISI 441 stainless steel, Top of AISI 304 stainless steel (20/10th).
%
%
- Water condenser.- Vertical turbine with automatic extraction.- Minimum mixing capacity 3 lit. and maximum 7 lit.- Noise level below 70 dB.- Vertical evaporator cylinders for a larger exchange surface.- Cycle with time control or temperature control.- Exclusive distribution device. - System self diagnosis.- Cycle time: 8/12 min.- Hourly production: 50 litres.NB: mainly for cold work.
%
Burners type wok 4x Ø 290 mm 21,44 kW und 3x Ø 230 mm 10,13 kW.Embedded cooking top, catching basin underneath.Lateral drain, pouring basin with removable filter, foreseen of a cover and a drain hole.1 control vane per burner, gas connection (4/4").Water curtain for the cooling of the top, inclusive a tap and a ranging rack.Made of AISI 441 stainless steel, Top of AISI 304 stainless steel (20/10th).
%
3 specially fixed slit-burners in iron, with a "grooved" steel burnerhead (28 kW), easily detachable, can be removed without tool, easy cleaning.Regulation by gas valves (control lever), with a light and a thermoelectric sensor.Every slit-burner has a plate for the collection of residues.Fixed wok ring, in cast iron, diam. 330 mm .Designed in stainless steel.Adjustable feet.
%
%
Chromium-nickel-steel top, strong thickness (5 mm).Iron slit-burners, chromium nickel-steel burner-heads,diam. 180 mm (13 kW), easily detachable, can be removed without tools, easy cleaning.Regulation by gas valves, with a light and a thermoelectric sensor.Every slit-burner has a plate for the collection of residues.Adjustable chromium-nickel-steel WOK ring.Cooling and cleaning system, by water curtain, channel for the collection, overflow drain.Designed in chromium-nickel-steel...
%
- Air condenser.- Vertical turbine with automatic extraction.- Minimum mixing capacity 4 lit. and maximum 8 lit.- Noise level below 70 dB.- Vertical evaporator cylinders for a larger exchange surface.- Cycle with time control or temperature control.- Exclusive distribution device. - System self diagnosis. - Cycle time: 8/12 min. - Hourly production: 60 litres.NB: mainly for cold work.
%
Chromium-nickel-steel top, strong thickness (5 mm).Iron slit-burners, with chromium nickel-steel burner-heads,diam. 180 mm (13 kW), easily detachable, can be removed without tools, easy cleaning.Regulation by gas valves, with a light and a thermoelectric sensor.Every slit-burner has a plate for the collection of residues.Adjustable chromium-nickel-steel WOK ring.Cooling and cleaning system, by water curtain, channel for the collection, overflow drain.Designed in chromium-nickel-steel...
%
- Air condenser.- Vertical turbine with automatic extraction.- Minimum mixing capacity 4 lit. and maximum 8 lit.- Noise level below 70 dB.- Vertical evaporator cylinders for a larger exchange surface.- Cycle with time control or temperature control.- Exclusive distribution device. - System self diagnosis. - Cycle time: 8/12 min. - Hourly production: 60 litres.NB: mainly for cold work.