Interior volume 9831 liters.Useful passage 720xh1860 mm. Galvanized steel panel recovered with a non-toxic plastic white film, food quality, polyurethane insulation injected at high density, eco-friendly (without CFC).Thickness of the wall, floor and ceiling = 80 mm.Locking of the panel by built-in "eccentric-gear" hooks.Anti-slip stainless steel floor.The angles and the corners of the floor, the ceiling and the walls are all at 135°, "sanitary".Very strong "bulging" door, reversible,...
%
For engine ventilator of type:10/10/0,75 - 10/10/1,1 - 10/10/1,5 - 12/12/1,5 - 12/12/2,2Fuses of protection for the safety of the engine.Compound casket of:* Switch one / off ( 2 speeds) coupled with a warning light,* Switch one / off, lighting coupled with a warning light,* Lock with key.- Metallic casket seals IP55.
%
Galvanized steel panels covered with a "non-toxic" white plastic film, food grade, high density injected polyurethane insulation, ecological (CFC-free).Wall, floor and ceiling thickness = 100 mm.Locking of the panels by built-in "eccentric" hooks.Stainless steel floor "non-slip".The corners and corners of the floor, sky and walls are all at 135° "sanitary".Very robust door, reversible, useful passage 900xh1860, closing by magnetic "pressure" seal (easy replacement, without tools), hinges with...
%
- Structures with slides for plates (2x8 levels) included, double row (600x400 EN or 530x325 GN1/1) - 2 glass doors- Structure for plates (74 mm), removable- Door in tempered glass (6 mm) with stainless steel handle- Heating through stainless steel armoured resistances- Adjustable slides- GN vat inside (on the bottom), tu put water and to humidify the cupboard- On/off switch- Mechanical thermosat (30° to 60°C) with pilot light- Manufactured in stainless steel- Adjustable stainless steel feet-...
%
For engine ventilator of type:10/10/0,75 - 10/10/1,1 - 10/10/1,5 - 12/12/1,5 - 12/12/2,2Fuses of protection for the safety of the engine.Compound casket of:* Switch one / off ( 2 speeds) coupled with a warning light,* Switch one / off, lighting coupled with a warning light,* Lock with key.- Metallic casket seals IP55.
%
Panels in galvanized steel covered with a white plastic film "not toxic", alimentary quality, isolation in injected polyurethane, high density, ecologic (w/o CFC's).Walls, floor and ceiling thickness = 100 mm.Locking of the panel by built-in "eccentric-gear" hooks.Floor in stainless steel. "anti-slip".Angles and corners of the floor, ceiling and floors, all at 135° '"sanitized".Very robust door, reversible, useful space 920xh1860, lock secured by magnetic seal "by pressure" (easy replacement...
%
- Structures with slides for plates (2x6 levels) included, double row (600x400 EN or 530x325 GN1/1) - 2 glass doors- Structure for plates (74 mm), removable- Door in tempered glass (6 mm) with stainless steel handle- Heating through stainless steel armoured resistances- Adjustable slides- GN vat inside (on the bottom), tu put water and to humidify the cupboard- On/off switch- Mechanical thermosat (30° to 60°C) with pilot light- Manufactured in stainless steel- Adjustable stainless steel feet-...
%
For engine ventilator of type:10/10/0,75 - 10/10/1,1 - 10/10/1,5 - 12/12/1,5 - 12/12/2,2Fuses of protection for the safety of the engine.Compound casket of:* Switch one / off ( 2 speeds) coupled with a warning light,* Switch one / off, lighting coupled with a warning light,* Lock with key.- Metallic casket seals IP55.
%
Panels in galvanized steel covered with a white plastic film "not toxic", alimentary quality, isolation in injected polyurethane, high density, ecologic (w/o CFC's).Walls, floor and ceiling thickness = 100 mm.Locking of the panel by built-in "eccentric-gear" hooks.Floor in stainless steel. "anti-slip".Angles and corners of the floor, ceiling and floors, all at 135° '"sanitized".Very robust door, reversible, useful space 920xh1860, lock secured by magnetic seal "by pressure" (easy replacement...
%
- Structures with slides for plates (8 levels) included, double row (600x400 EN ou 530x325 GN1/1) - 2 glass doors- Structure for plates (74 mm), removable- Door in tempered glass (6 mm) with stainless steel handle- Heating through stainless steel armoured resistances- Adjustable slides- GN vat inside (on the bottom), tu put water and to humidify the cupboard- On/off switch- Mechanical thermosat (30° to 60°C) with pilot light- Manufactured in stainless steel- Adjustable stainless steel feet-...
%
%
Interior volume 10182 liters.Useful passage 720xh1860mm Galvanized steel panel recovered with a non-toxic plastic white film, food quality, polyurethane insulation injected at high density, eco-friendly (without CFC).Thickness of the wall, floor and ceiling = 80 mm.Locking of the panel by built-in "eccentric-gear" hooks.Anti-slip stainless steel floor.The angles and the corners of the floor, the ceiling and the walls are all at 135°, "sanitary".Very strong "bulging" door, reversible,...
%
- Structures with slides for plates (8 levels) included (460x340 or 433x333 or 353x325 GN2/3) - Glass door- Structure for plates (74 mm), removable- Door in tempered glass (6 mm) with stainless steel handle- Heating through stainless steel armoured resistances- Adjustable slides- GN vat inside (on the bottom), tu put water and to humidify the cupboard- On/off switch- Mechanical thermosat (30° to 60°C) with pilot light- Manufactured in stainless steel- Adjustable stainless steel feet-...
%
Structures with slides for plates (8 levels) included, double row (600x400 EN ou 530x325 GN1/1)2 glass doors Structure for plates (74 mm), removable.Door in tempered glass (6 mm) with stainless steel handleHeating through stainless steel armoured resistancesAdjustable slidesGN vat inside (on the bottom), to put water and to humidify the cupboardOn/off switchMechanical thermosat (30° to 60°C) with pilot lightManufactured in stainless steelAdjustable stainless steel feetEquipment manufactured...
%
%
Structures with slides for plates (8 levels) included (460x340 or 433x333 or 353x325 GN2/3)Glass door Structure for plates (74 mm), removableDoor in tempered glass (6 mm) with stainless steel handleHeating through stainless steel armoured resistancesAdjustable slidesGN vat inside (on the bottom), tu put water and to humidify the cupboardOn/off switchMechanical thermosat (30° to 60°C) with pilot lightManufactured in stainless steelAdjustable stainless steel feetEquipment manufactured following...
%
Interior volume 13037 liters.Useful passage 720xh1860mm Galvanized steel panel recovered with a non-toxic plastic white film, food quality, polyurethane insulation injected at high density, eco-friendly (without CFC).Thickness of the wall, floor and ceiling = 80 mm.Locking of the panel by built-in "eccentric-gear" hooks.Anti-slip stainless steel floor.The angles and the corners of the floor, the ceiling and the walls are all at 135°, "sanitary".Very strong "bulging" door, reversible,...
%
Interior volume 11434 liters.Useful passage 720xh1860 mm. Galvanized steel panel recovered with a non-toxic plastic white film, food quality, polyurethane insulation injected at high density, eco-friendly (without CFC).Thickness of the wall, floor and ceiling = 100 mm.Locking of the panel by built-in "eccentric-gear" hooks.Anti-slip stainless steel floor.The angles and the corners of the floor, the ceiling and the walls are all at 135°, "sanitary".Very strong "bulging" door, reversible,...
%
Interior volume 11610 liters.Useful passage 720xh1860 mm. Galvanized steel panel recovered with a non-toxic plastic white film, food quality, polyurethane insulation injected at high density, eco-friendly (without CFC).Thickness of the wall, floor and ceiling = 100 mm.Locking of the panel by built-in "eccentric-gear" hooks.Anti-slip stainless steel floor.The angles and the corners of the floor, the ceiling and the walls are all at 135°, "sanitary".Very strong "bulging" door, reversible,...
%
Unit width 400 mm, small footprint.Cooling capacity 671 (W/f) for chamber volume 3,6 m³ / 3600 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Unit width 400 mm, small footprint.Cooling capacity 817 (W/f) for chamber volume 4,8 m³ / 4800 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Unit width 400 mm, small footprint.Cooling capacity 953 (W/f) for chamber volume 6,1 m³ / 6100 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Cooling capacity 1577 (W/f) for chamber volume 16,3 m³ / 16300 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%