%
- Air condenser.- Vertical turbine, ideal for restaurants, requires little maintenance and is very easy to use. - Easy installation due to its compact size. - Minimum mixing capacity 0.5 lit. and maximum 1 lit. - Noise level lower than 70 dB. - Cycle with time control or temperature control. - Vertical evaporator cylinders for a larger exchange surface. - Exclusive distribution device. - System self diagnosis. - Cycle time: 15/20 min. - Hourly production: 5 liters. NB: mainly for cold work.
%
Automatic roll up system.Maximum pressure to use is 6 bars and temperature 60°C.Waterflow 10 liters/min.Bodywork in stainless steel 18/10 AISI 304 (brushed finishing touch).N.B.: delivered without faucet for connection.
%
Realisation "double walled". with thermic insulation.Watersoftener continuously, incorporated (WARNING: connection to cold water).Charging height diam. 465 mm.Standard rinsing pump (atmospheric boiler). Control panel at the top of the hood, digital display.Basket 600x500 mm, capacity 22 plates, dishes 600x400 (see accessories), beer baskets 600x400 to 135 Lt, always the possibility of using 500x500 mm baskets. 3 cycles: 60 '- 110' - 150 '' or continuous.Device opening and closing cover on...
%
Head in galvanized and stamped steel which garantees a good relationship flexibility/rigidity.Blue anodized handle.
%
- Air condenser.- Vertical turbine with automatic extraction. - Minimum mixing capacity 2 litres and maximum 4 litres. - Noise level below 70 dB. - Vertical evaporator cylinders for a larger exchange surface. - Cycle with time control or temperature control. - Exclusive distribution device. - System self diagnosis. - Cycle time: 10/15 min. - Hourly production: 20 litres. NB: mainly for cold work, delivered on wheels.
%
Wall-mounted model, placed at a height of 1.50 m from the ground.Automatic rewind system.Pistol and trigger handle with no-drip system.Maximum operating pressure of 8.5 bar and temperature 60°C.Water flow rate 12 litres/min.Bodywork in 18/10 stainless steel AISI 304 (brushed finish).NB: supplied without "mixing valve" connection.
%
Realization in "double walls" with thermal insulationIntegration of the "Green System H.R.S. Condenser-recovery of vapors, great energy saving (ATTENTION: connection to cold water)Continuous water softener, incorporated (ATTENTION: connection to cold water)Loading height 465 mmStandard flush pump (atmospheric boiler). Control panel on top of the cover, digital displayBasket 600x500 mm, capacity 22 plates, plates 600x400 (see accessory), beer baskets 600x400 up to 135 Lt, still possible to use...
%
Head in galvanized and stamped steel which guarantees a good relationship flexibility/rigidity.Blue anodized handle.
%
%
Wall-mounted model, placed at a height of 1.50 m from the ground.Automatic rewind system.Pistol and trigger handle with no-drip system.Maximum operating pressure of 8.5 bar and temperature 60°C.Water flow rate 12 litres/min.Bodywork in 18/10 stainless steel AISI 304 (brushed finish).NB: supplied without "mixing valve" connection.
%
%
Head in galvanized and stamped steel which guarantees a good relationship flexibility/rigidity.Blue anodized handle.
%
- Air condenser.- Vertical turbine with automatic extraction.- Minimum mixing capacity 3 lit. and maximum 7 lit.- Noise level below 70 dB.- Vertical evaporator cylinders for a larger exchange surface.- Cycle with time control or temperature control.- Exclusive distribution device. - System self diagnosis.- Cycle time: 8/12 min.- Hourly production: 50 litres.NB: mainly for cold work
%
Model with wall fixation, placed at a height of 1,50 m of the floor.Automatic roll up system.Gun type handle and trigger equiped with a "no-drip" system.Maximum pressure tu use is 8.5 bars and temperature 60°C.Waterflow 10 liters/min.Bodywork in stainless steel 18/10 AISI 304 (brushed finishing touch).N.B.: delivered without faucet for connection.
%
%
15 levels, spaced 35 mm.Made in stained steel AISI 304.
%
- Air condenser.- Vertical turbine with automatic extraction.- Minimum mixing capacity 3 lit. and maximum 7 lit.- Noise level below 70 dB.- Vertical evaporator cylinders for a larger exchange surface.- Cycle with time control or temperature control.- Exclusive distribution device. - System self diagnosis.- Cycle time: 8/12 min.- Hourly production: 50 litres.NB: mainly for cold work.
%
%
%
Cutter in stained steel AISI 304.Nylon handle.
%
Automatic roll up system.Maximum pressure to use is 6 bars and temperature 60°C.Waterflow 11 liters/min.Bodywork in stainless steel 18/10 AISI 304 (high-gloss brushed finish).N.B.: delivered without faucet for connection.
%
- Water condenser.- Vertical turbine with automatic extraction.- Minimum mixing capacity 3 lit. and maximum 7 lit.- Noise level below 70 dB.- Vertical evaporator cylinders for a larger exchange surface.- Cycle with time control or temperature control.- Exclusive distribution device. - System self diagnosis.- Cycle time: 8/12 min.- Hourly production: 50 litres.NB: mainly for cold work.
%
%
Palet made of stained steel AISI 304, dimensions : 72x120 mm.Nylon handle.